Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The double-blinded and randomized study evaluated the effectiveness and side effects of a novel non-invasive treatment, Schumann resonance (SR), in treating insomnia. The objective of this study is (1) to evaluate the improvement of sleep quality of patients with insomnia disorder by SR and (2) to be the basis for the future development of physical magnetic therapy.
Insomnia is a common sleep disturbance that affects the health and quality of life of individuals and accounts for considerable utilization of medical resources. The prevalence of insomnia is approximately 30%; in Asia, the prevalence of insomnia is approximately 4% in Japan, 9.9% in South Korea, 10.3% in Taiwan. Based on the statistic of Taiwan BNHI office in a 2013 report, there is worth of 1.3 billion prescriptions of hypnotic drug in one year. In addition, the reimbursement expenditure pays up more than 1 billion New Taiwan Dollars (NTD) with increasing expense rate of 15% every year, showing insomnia causes great distress to Taiwanese.
The characteristics of insomnia are difficulty with initiating or maintaining sleep, early morning waking, or non-restorative sleep. In DSM-5, the diagnosis of primary insomnia has been renamed insomnia disorder to avoid the differentiation between primary and secondary insomnia.
The most common treatment for insomnia is pharmacological therapy with hypnotics such as a benzodiazepine, zolpidem, or zopiclone. However, treatment with hypnotics includes the risk of adverse effects, drug tolerance and dependence . Some past reports on different non-pharmacological treatment strategies, such as Cognitive-Behavioral Therapy (CBT), muscle relaxation training, stimulus control, sleep restriction, and sleep hygiene, have demonstrated the effectiveness of most of these non-pharmacological treatments. However, the poor compliance and inconvenience for CBT is always a big issue.
Except the traditional treatment of insomnia, some folk therapies' clinical effect does not been confirmed, such as aromatherapy, music therapy, etc. Nowadays, due to development of technology for medical devices, some sleep devices were launched, aim to prolong the slow-wave sleep and enhances the sleeping quality.
The investigational device in this study is a sleep device with SRF (Sleep Restore Frequency), the principle is to integrate the bio-energy generated Schumann resonances, native from Earth, and the shocks from the Earth's magnetic field. Through the non-contact method with bio-energy waves, SRF are coupled to the sleep center of the brain, inducing and adjusting the electrical activities of the sleep center. It prolongs the in-depth sleep and enhances the sleeping quality.
The objective of this study is (1) to evaluate the improvement of sleep quality of patients with insomnia disorder by sleep device and (2) to be the basis for the future development of physical magnetic therapy.
Sample Size Approximately 60 subjects who meet the inclusion and exclusion criteria will be enrolled into the trial and averagely separated two arms for statistical analysis.
Statistical Analysis Efficacy evaluation statistics will be conducted with independent t-test or Fisher's exact test for testing the differences and conducted with Pearson correlation coefficient for the association between variables.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SR device group | Experimental |
| |
| placebo device group | Placebo Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Schumann resonance sleep device | Device | A Schumann resonance sleep device would stably output the composite frequency of a "the Schumann resonance frequency (7.83 Hz) wave, theta wave, and delta wave". The subjects were asked to use the device (place it next to the bed facing the subject's head, turn it on about one hour before going to bed every night, and turn it off after getting up the next day) every night for four weeks. |
| Measure | Description | Time Frame |
|---|---|---|
| actigraphy | Change in sleep latency (mins) based on actigraphy from before treatment to after treatment. | 4 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| actigraphy-TST | Total sleep time (TST, mins) based on actigraphy from before treatment to after treatment. | 4 weeks |
| actigraphy-SE | Sleep efficiency (SE, %) based on actigraphy from before treatment to after treatment. |
| Measure | Description | Time Frame |
|---|---|---|
| heart rate variability (HRV) device | The measurement method is to stick four patches on participants body and measure the heart rhythm state for 10 minutes. An estimate was computed for LF/HF ratio. | before, after 2 weeks, and after 4 weeks using sleep device |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Yu-shu Huang, MD.PhD. | Contact | 886-975365659 | yushuhuang1212@gmail.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chang Gung Memorial Hospital, Linkou | Recruiting | Taoyuan City | 333423 | Taiwan |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D007319 | Sleep Initiation and Maintenance Disorders |
| ID | Term |
|---|---|
| D020919 | Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Placebo sleep device | Device | A Placebo sleep device is an instrument with the same appearance and operation as the Schumann resonance sleep device, but does not output any frequency wave. The subjects were asked to use the device (place it next to the bed facing the subject's head, turn it on about one hour before going to bed every night, and turn it off after getting up the next day) every night for four weeks. |
|
| 4 weeks |
| actigraphy-WASO | Wake after sleep onset (WASO) based on actigraphy from before treatment to after treatment. | 4 weeks |
| polysomnography (PSG)-SL | Change in sleep latency (SL, mins) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| polysomnography (PSG)-TST | Change in total sleep time (TST, mins) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| polysomnography (PSG)-SE | Change in sleep efficiency (SE, %) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| polysomnography (PSG)-WASO | Change in wake after sleep onset (WASO, mins) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| polysomnography (PSG)-SWS | Change in slow wave sleep (SWS, %) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| polysomnography (PSG)-REM | Change in REM sleep (%) based on PSG from before treatment to after treatment. | before and after 4 weeks using sleep device |
| Pittsburgh Sleep Quality Index (PSQI) | The Pittsburgh Sleep Quality Index (PSQI) is a self-rated questionnaire for assessing the subjective sleep quality, which consists of 19 items and can be calculated and combined into 7 clinically-derived component score (0-3), with higher scores indicating worse sleep quality. | before, after 2 weeks, and after 4 weeks using sleep device |
| 36-Item Short-Form Health Survey (SF-36) | 36-Item Short-Form Health Survey (SF-36) includes 11 major questions that evaluate eight components (0-100), with higher scores indicating better outcome.These components include physical functioning, role limitations due to physical health, role limitations due to emotional problems, energy/fatigue, emotional wellbeing, social functioning, pain, and general health. | before, after 2 weeks, and after 4 weeks using sleep device |
| sleep diary (sleep logs)-SL | From the diaries, an estimate was computed for an average of sleep latency (SL, mins). | before, after 2 weeks, and after 4 weeks using sleep device |
| sleep diary (sleep logs)-TST | From the diaries, an estimate was computed for an average of total sleep time (TST, mins). | before, after 2 weeks, and after 4 weeks using sleep device |
| sleep diary questionaire (sleep logs)-SE | From the diaries, an estimate was computed for an average of sleep efficiency (SE, %). | before, after 2 weeks, and after 4 weeks using sleep device |
| D001523 |
| Mental Disorders |