Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Fluid administration is one of the main strategies for patients with acute circulatory failure. However, about half of the patients could not benefit from the fluid administration after the ICU admission. Thus predict the effect of fluid responsiveness is essential. There are sevral indices or tests can be used, such as pulse pressure variation (PPV), end-expiratory occulsion test (EEOT), passive leg raising (PLR), etc. Question of the prevalence of cases in which the different predictive indices of fluid responsiveness in intensive care unit (ICU) are not applicable.
Fluid administration is one of the first-line therapies for most patients with acute circulatory failure. And it was supposed to increase cardiac preload and thus output significantly. However, it only has this effect if cardiac output is dependent on cardiac preload, that is if both ventricles work on the ascending part of the Frank-Starling curve. Our group had already shown that, in half of the critically ill patients admitted in ICU, fluid administration is likely to exert only deleterious effects without any hemodynamic benefit. To predict whether it will exert beneficial effects or not before administering the fluid therapy, a "dynamic approach" has been developed. It consists of observing the effects of changes of preload induced by various tests on cardiac output. 1) Pulse pressure variation: mechanical ventilation induces cyclical changes in cyclical changes in cardiac preload and right ventricular afterload due to cardiopulmonary interactions. If both ventricles are in a preload-dependent state, these variations will induce a cyclical variation in stroke volume. The latter being physiologically related to the pulsed arterial pressure (systolic - diastolic), the respiratory variation of the pulsed arterial pressure (PPV) indicates the existence of a preload-dependence of the two ventricles. 2) The End-expiratory occlusion test (EEOT): this is another method that takes advantage of heart-lung interactions to predict fluid responsiveness in ventilated patients. During mechanical ventilation, each insufflation increases intrathoracic pressure, which hinders systemic venous return. Thus, interrupting the respiratory cycle at the end of expiration inhibits this cyclic hindrance to venous return, increases cardiac preload and cardiac output if both ventricles are preload dependent. The duration of the EEOT must be at least 15 seconds. 3): Passive leg raising (PLR): when a patient is in a recumbent position, the elevation of the lower extremities and the horizontalization of the trunk passively transfers a significant volume of blood from the lower part of the body to the heart chambers and mimics volume expansion.
Numerous studies have reported that the increased cardiac output induced by PLR predicts fluid responsiveness. There is always the question of the prevalence of cases in which the different predictive indices of fluid responsiveness are not applicable and data on this issue are scarce, incomplete, and unsatisfactory.
Few studies have systematically investigated the number of patients in whom PPV cannot be used in the ICU settings. Some studies have reported a very low prevalence of cases where PPV was usable but they included the entire ICU population on a given day, including many patients who did not have an acute circulatory failure, which had no sense since PPV is only used in patients in whom the question of fluid therapy arises. Other studies have reported a higher prevalence of cases where PPV is usable, but they have only looked at the first 24 hours of hospitalization or have focused on patients with an unstable hemodynamic event. Finally, no study has ever studied the prevalence of cases where the respiratory variation of the PLR, or the EEOT are not applicable.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Passive leg raising | Other | We perform the PLR test by adjusting the bed and not by manually raising the patient's legs. Bronchial secretions must be carefully aspirated before PLR. If awake, the patient should be informed of what the test involves. And measure the cardiac output by using certain devices at the bedside. The end-expiratory occlusion consists in interrupting the ventilator at end-expiration for 15-30 s and assessing the resulting changes in cardiac output. |
|
| Measure | Description | Time Frame |
|---|---|---|
| The prevalence of cases and reasons in which the conditions that the PPV cannot be correctly interpreted. | By using one arterial line, the scope at the bedside could have a PPV value that automatly calculated on the screen. | One minute at the bedside |
| The prevalence of cases and reasons in which the conditions that the EEOT cannot be correctly interpreted. | 15 seconds for EEOT | |
| The prevalence of cases and reasons in which the conditions that the PLR cannot be correctly interpreted. | One minute fot the passive leg raising |
Not provided
Not provided
Inclusion Criteria:
Age ≥ 18
The presence of acute circulatory insufficiency defined by the following pragmatic criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Adult patients with acute circulatory failure need to evaluate fluid responsiveness.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Rui SHI, M.D. | Contact | 0642170297 | rui.shi@u-psud.fr | |
| Xavier MONNET, M.D.,Ph.D. | Contact | 06 60 86 26 69 | xavier.monnet@aphp.fr |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical Intensive Care Unit | Recruiting | Le Kremlin-Bicêtre | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26798642 | Background | Benes J, Kirov M, Kuzkov V, Lainscak M, Molnar Z, Voga G, Monnet X. Fluid Therapy: Double-Edged Sword during Critical Care? Biomed Res Int. 2015;2015:729075. doi: 10.1155/2015/729075. Epub 2015 Dec 22. | |
| 12065368 | Background | Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002 Jun;121(6):2000-8. doi: 10.1378/chest.121.6.2000. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012769 | Shock |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
| 10903232 | Background | Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000 Jul;162(1):134-8. doi: 10.1164/ajrccm.162.1.9903035. |
| 19602972 | Background | Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009 Sep;37(9):2642-7. doi: 10.1097/CCM.0b013e3181a590da. |
| 16846530 | Background | Heenen S, De Backer D, Vincent JL. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10(4):R102. doi: 10.1186/cc4970. |
| 17508201 | Background | Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007 Jul;33(7):1117-1124. doi: 10.1007/s00134-007-0644-9. Epub 2007 May 17. |
| 19847400 | Background | Muller L, Louart G, Bousquet PJ, Candela D, Zoric L, de La Coussaye JE, Jaber S, Lefrant JY. The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med. 2010 Mar;36(3):496-503. doi: 10.1007/s00134-009-1686-y. Epub 2009 Oct 22. |
| 20724891 | Background | Malbrain ML, Reuter DA. Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! Crit Care Med. 2010 Sep;38(9):1912-5. doi: 10.1097/CCM.0b013e3181f1b6a2. No abstract available. |
| 27127648 | Background | Delannoy B, Wallet F, Maucort-Boulch D, Page M, Kaaki M, Schoeffler M, Alexander B, Desebbe O. Applicability of Pulse Pressure Variation during Unstable Hemodynamic Events in the Intensive Care Unit: A Five-Day Prospective Multicenter Study. Crit Care Res Pract. 2016;2016:7162190. doi: 10.1155/2016/7162190. Epub 2016 Mar 31. |