Today, tooth- or implant-supported single crowns and short-span fixed partial dentures can be fabricated on the basis of an intraoral scan, but the scanning accuracy decreases with increasing length of the jaw section to be captured. An accurate scan is also made more difficult by edentulous jaw sections, as these provide the scanner with few landmarks for proper three-dimensional image composition.
With respect to both edentulous and edentulous patients with dental implants, the currently available literature does not provide a firm basis for deciding whether such patients can already be scanned with sufficient accuracy. It is considered problematic in this context that the findings on digital impression accuracy, regardless of whether teeth or implants have been scanned, are based almost exclusively on the results of in vitro studies. Conclusions about the accuracy of intraoral scanners under clinical conditions with moving patients and limited accessibility to the structures to be imaged, especially in the presence of blood, saliva or sulcus fluid, are extremely limited based on these data.
Therefore, the aim of this study is to determine the clinical scanning accuracy of two current intraoral scanning systems for the three-dimensional acquisition of the position of two interforaminal dental implants in the edentulous mandible. The influence of artificial landmarks to achieve increased scan accuracy will also be tested.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Locator Group | The participant has a mandibular overdenture supported by two implants with locator attachments. The implants are scanned with each of two intraoral scanners both with and without the use of artificial landmarks. The implant scans are analyzed in terms of scanning accuracy (trueness and precision) by comparison with a reference model (3D implant positions in the working cast of the immediately loaded overdenture). | ||
| Bar Group | The participant has a mandibular overdenture supported by two implants with a dolder bar attachment. The implants are scanned with each of two intraoral scanners both with and without the use of artificial landmarks. The implant scans are analyzed in terms of scanning accuracy (trueness and precision) by comparison with a reference model (3D implant positions in the working cast of the immediately loaded overdenture). |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Effect of intraoral scanner on scanning accuracy | Accuracy will be given as trueness and precision according to ISO 20896-1:2019 Dentistry - Digital impression devices - Part 1: Methods for assessing accuracy. Implant distance deviations will be measured in [µm] and implant angle deviations in [°]. | through study completion, an average of 2 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Effect of artificial landmarks on scanning accuracy | Accuracy will be given as trueness and precision according to ISO 20896-1:2019 Dentistry - Digital impression devices - Part 1: Methods for assessing accuracy. Implant distance deviations will be measured in [µm] and implant angle deviations in [°]. | through study completion, an average of 2 hours |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Participants had received a mandibular overdenture supported by two implants with either Locator attachments or a Dodler bar attachment following an immediate loading protocol as part of a randomized controlled trial [Kappel S, Giannakopoulos NN, Eberhard L, Rammelsberg P, Eiffler C. Immediate Loading of Dental Implants in Edentulous Mandibles by Use of Locator® Attachments or Dolder® Bars: Two-Year Results from a Prospective Randomized Clinical Study. Clin Implant Dent Relat Res. 2016 Aug;18(4):752-61. doi: 10.1111/cid.12349. Epub 2015 May 7. PMID: 25950679.].
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Wolfgang Bömicke, Prof. Dr. | Department of Prosthetic Dentistry, University of Heidelberg | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg | Heidelberg | Baden-Wurttemberg | 69120 | Germany |
Not provided
| ID | Term |
|---|---|
| D007575 | Jaw, Edentulous |
| ID | Term |
|---|---|
| D007571 | Jaw Diseases |
| D009140 | Musculoskeletal Diseases |
| D009057 | Stomatognathic Diseases |
| D009066 | Mouth, Edentulous |
Not provided
Not provided
Not provided
Not provided
Not provided
| Effect of implant attachment on scanning accuracy in [µm] and [°] | Accuracy will be given as trueness and precision according to ISO 20896-1:2019 Dentistry - Digital impression devices - Part 1: Methods for assessing accuracy. Implant distance deviations will be measured in [µm] and implant angle deviations in [°]. | through study completion, an average of 2 hours |
| Effect of intraoral scanner/use of artificial landmarks on intraoral scanning process/quality of the 3D dataset by a study investigator on the basis of qualitative criteria (see description) | Effect of intraoral scanner/use of artificial landmarks on intraoral scanning process (successful, successful with difficulties, failed)/quality of the 3D dataset (Surface irregularities, deformations, stitching errors, other) | through study completion, an average of 2 hours |
| D009059 |
| Mouth Diseases |
| D014076 | Tooth Diseases |