This proof-of-concept study aims to determine the feasibility and effectiveness of using a custom head-mounted device for visual field testing. The novel head-mounted device, with custom software, will be compared to a conventional visual field test: The Humphrey Visual Field Analyzer. The investigators will include 30 healthy normal patients, 30 glaucoma suspects, 30 patients with moderate glaucoma, and 30 patients with advanced glaucoma (total: 120 patients). Each patient will perform the conventional test and the head-mounted device visual field test during the study visit, with the order (i.e., which device the patient starts with) being randomized. After the two tests, the patient will fill out a questionnaire to gather information regarding patient comfort and satisfaction. This will repeat each week for 5 weeks, for a total of 5 study visits. The results of the tests (sensitivity thresholds) will be compared. The investigators hypothesize that the results of the conventional and head-mounted device will be similar.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single Arm | Experimental | Patients will perform visual field testing with the Humphrey Visual Field Analyzer and with the custom head-mounted device. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Visual Field Testing | Diagnostic Test | Visual field testing using the protocol 24-2 and/or 10-2 Threshold Test |
|
| Measure | Description | Time Frame |
|---|---|---|
| Visual field differential light sensitivity | Comparison of differential light sensitivity threshold estimated with the Humphrey Visual Field Analyzer and the custom head-mounted device. | 5 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Reproducibility of sensitivity values | Comparison of the reproducibility of sensitivity values estimated with the Humphrey Visual Field Analyzer and the custom head-mounted device. | 5 weeks |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Brennan Eadie, MD, PhD | Contact | 902-292-0873 | eadie.brennan.d@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Brennan Eadie, MD, PhD | Nova Scotia Healthy Authority | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Victoria General Hopsital - Nova Scotia Health Authority | Halifax | Nova Scotia | B3H 2Y9 | Canada |
Not provided
| ID | Term |
|---|---|
| D005901 | Glaucoma |
| ID | Term |
|---|---|
| D009798 | Ocular Hypertension |
| D005128 | Eye Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D014794 | Visual Fields |
| ID | Term |
|---|---|
| D009799 | Ocular Physiological Phenomena |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Eadie Technologies Inc. | Halifax | Nova Scotia | B3L 4W8 | Canada |
|