Bite testing using T-Scan allows the evaluation of occlusal contacts prior to making a bite adjustment. The T-Scan can indicate premature contact and the load distribution on teeth, and provide measurable force and time information that ensures proper occlusal adjustment.
Prior to employing T-Scan occlusal analyzer to assess the occlusion on the complete denture, complete denture was seated and checked for fitness, stability, pressure areas with pressure indicating paste and border evaluation and extension. The peripheral seal should be evident so that the denture-maintained suction against maxillary tissues. Upon completion of these fit and stability assessments, the occlusion could then be addressed.
The method considered for the occlusal analysis was a computerized system . The system was composed of a computer with a specific board and software capable of converting information recorded by the sensor to visual and numerical information on tooth contact. For Tekscan system to function properly, computer system must meet or exceed specified system requirements.
The Tekscan USB handle, does not require an additional interface card or parallel box in order tobe connected to computer. When inserted into computer, the computer's operating system will automatically detect and configure the hardware for use. The T-Scan sensor was an ultra-thin (.004", 0.1 mm), flexible printed circuit that detected the patient's occlusal parameters.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Complete denture | Active Comparator | Conventional complete denture without supporting devices |
|
| Ultra suction retained complete denture | Experimental | Conventional complete denture with ultra suction device |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| T scan | Device | Occlusal load analysis |
|
| Measure | Description | Time Frame |
|---|---|---|
| Occlusal load analysis | occlusal load analysis of the ultra suction system in complete denture being evaluated by T-scan system | One year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| El Naagar | Badr university in Cairo | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Badr university in Cairo | Cairo | Egypt |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP_ICF | Yes | Yes | Yes | Study Protocol, Statistical Analysis Plan, and Informed Consent Form | Aug 15, 2020 | Aug 2, 2021 | Prot_SAP_ICF_000.pdf |