Due to the limitations of current approaches to assess emergency paramedics' fatigue, a portable, quick, easy, and objective technique is required to be developed. The aim of the study was to investigate the reliability of automated pupillometry to assess mental fatigue based on a driver simulator.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| fatigue | After enrollments, subjects were assigned to perform mental fatigue-inducing experiment-a 90 min of monotonous simulated driving task. They underwent repeated measurements of quantitative pupillary light reflex (PLR) using an automated quantitative pupillometer at baseline and at an interval of 30 min during the task. Subjective ratings, heart rate variability (HRV), and electroencephalography (EEG) were performed simultaneously. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| pupillometer | Diagnostic Test | The dynamic changes of PLR were measured using the PLR-3000 pupillometer (NeurOptics, CA, USA), a hand-held portable device. Determination of PLR with automated pupillometry can be performed with a rubber cup covering the measured eye and the subject's hand covering the non-measured eye. A flash of visible white light with a duration of 0.8 sec and a pulse intensity of 50 µW is delivered to induce a pupillary reflex, and repeated video images at more than 30 frames/sec are stored for 6.65 sec. The device provided the examiner with maximum and minimum pupil size (Init and End), constriction percentage (%PLR), latency (LAT), constriction and dilation velocity (CV and DV), and T75. |
| Measure | Description | Time Frame |
|---|---|---|
| subjective assessments | Karolinska Sleepiness Scale (KSS), a 9-point scale for assessing sleepiness with responses ranging from extremely alert (1) to very sleepy (9) . | Baseline |
| subjective assessments | Karolinska Sleepiness Scale (KSS), a 9-point scale for assessing sleepiness with responses ranging from extremely alert (1) to very sleepy (9) . | 30 minutes |
| subjective assessments | Karolinska Sleepiness Scale (KSS), a 9-point scale for assessing sleepiness with responses ranging from extremely alert (1) to very sleepy (9) . | 60 minutes |
| subjective assessments | Karolinska Sleepiness Scale (KSS), a 9-point scale for assessing sleepiness with responses ranging from extremely alert (1) to very sleepy (9) . | 90 minutes |
| Standard deviation of the NN intervals of heart rate variability | Using the SA-3000P (Medicore, Korea) , subjects were instructed to stay with eyes open, be silent, and breath normally during measurement. | Baseline |
| Standard deviation of the NN intervals of heart rate variability | Using the SA-3000P (Medicore, Korea) , subjects were instructed to stay with eyes open, be silent, and breath normally during measurement. | 30 minutes |
| Standard deviation of the NN intervals of heart rate variability |
| Measure | Description | Time Frame |
|---|---|---|
| Electroencephalography power in theta band | The eego™ mylab system (ANT Neuro, Germany) was applied to record the raw electroencephalography signal, using a 64-channel waveguard™ original electrode cap with electrodes in accordance with the international 10 ~ 20 Montage system. electroencephalography was sampled with a frequency of 1kHz using an eego™ amplifier. Electrode impedences of the selected channels were kept below 5 kΩ before recording. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Healthy postgraduate students from Zhejiang University School of Medicine in China voluntarily participated in our study. All participants were asked to follow the below requirements before the tests: 1) refrain from alcohol, caffeine and tea within 12 h, 2) adequate sleep (almost 6~8 h) the day before, and 3) wash the hair within 24 h. Informed written consent and training were provided prior to entering the experiment.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mao Zhang | 2nd Affiliated Hospital, School of Medicine, Zhejiang University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Second Affiliated Hospital, Zhejiang University School of Medicine & Institute of Emergency Medicine, Zhejiang University | Hangzhou | Zhejiang | 310009 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D005222 | Mental Fatigue |
| ID | Term |
|---|---|
| D005221 | Fatigue |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001526 | Behavioral Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
|
Using the SA-3000P (Medicore, Korea) , subjects were instructed to stay with eyes open, be silent, and breath normally during measurement.
| 60 minutes |
| Standard deviation of the NN intervals of heart rate variability | Using the SA-3000P (Medicore, Korea) , subjects were instructed to stay with eyes open, be silent, and breath normally during measurement. | 90 minutes |
| %PLR (percentage of change) | The dynamic changes of pupillary light reflex were measured using the PLR-3000 pupillometer (NeurOptics, CA, USA), a hand-held portable device. Determination of pupillary light reflex with automated pupillometry can be performed with a rubber cup covering the measured eye and the subject's hand covering the non-measured eye. A flash of visible white light with a duration of 0.8 sec and a pulse intensity of 50 µW is delivered to induce a pupillary reflex, and repeated video images at more than 30 frames/sec are stored for 6.65 sec. | Baseline |
| %PLR (percentage of change) | The dynamic changes of pupillary light reflex were measured using the PLR-3000 pupillometer (NeurOptics, CA, USA), a hand-held portable device. Determination of pupillary light reflex with automated pupillometry can be performed with a rubber cup covering the measured eye and the subject's hand covering the non-measured eye. A flash of visible white light with a duration of 0.8 sec and a pulse intensity of 50 µW is delivered to induce a pupillary reflex, and repeated video images at more than 30 frames/sec are stored for 6.65 sec. | 30 minutes |
| %PLR (percentage of change) | The dynamic changes of pupillary light reflex were measured using the PLR-3000 pupillometer (NeurOptics, CA, USA), a hand-held portable device. Determination of pupillary light reflex with automated pupillometry can be performed with a rubber cup covering the measured eye and the subject's hand covering the non-measured eye. A flash of visible white light with a duration of 0.8 sec and a pulse intensity of 50 µW is delivered to induce a pupillary reflex, and repeated video images at more than 30 frames/sec are stored for 6.65 sec. | 60 minutes |
| %PLR (percentage of change) | The dynamic changes of pupillary light reflex were measured using the PLR-3000 pupillometer (NeurOptics, CA, USA), a hand-held portable device. Determination of pupillary light reflex with automated pupillometry can be performed with a rubber cup covering the measured eye and the subject's hand covering the non-measured eye. A flash of visible white light with a duration of 0.8 sec and a pulse intensity of 50 µW is delivered to induce a pupillary reflex, and repeated video images at more than 30 frames/sec are stored for 6.65 sec. | 90 minutes |
| Baseline |
| Electroencephalography power in theta band | The eego™ mylab system (ANT Neuro, Germany) was applied to record the raw electroencephalography signal, using a 64-channel waveguard™ original electrode cap with electrodes in accordance with the international 10 ~ 20 Montage system. electroencephalography was sampled with a frequency of 1kHz using an eego™ amplifier. Electrode impedences of the selected channels were kept below 5 kΩ before recording. | 30 minutes |
| Electroencephalography power in theta band | The eego™ mylab system (ANT Neuro, Germany) was applied to record the raw electroencephalography signal, using a 64-channel waveguard™ original electrode cap with electrodes in accordance with the international 10 ~ 20 Montage system. electroencephalography was sampled with a frequency of 1kHz using an eego™ amplifier. Electrode impedences of the selected channels were kept below 5 kΩ before recording. | 60 minutes |
| Electroencephalography power in theta band | The eego™ mylab system (ANT Neuro, Germany) was applied to record the raw electroencephalography signal, using a 64-channel waveguard™ original electrode cap with electrodes in accordance with the international 10 ~ 20 Montage system. electroencephalography was sampled with a frequency of 1kHz using an eego™ amplifier. Electrode impedences of the selected channels were kept below 5 kΩ before recording. | 90 minutes |
| D001519 | Behavior |