Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
There is no difference of the photic phenomena in the two groups.
The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power.
The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power.
We used the 'TrialSize' package of the R software. Here are the parameters defined for the sample size calculation:
Equivalence limit: 0.10 In order to show no difference between these two groups, 26 patients by groups are needed. With a drop-out of 15%, we obtain 62 patients (31 patients by group) to recruit in order to obtain 52 valuable patients.
This total number of subjects with such requirement is 26 patients in each group.
Group 1 will be made of 26 patients with corneal astigmatism higher than 1.0D in both eyes and lower than 2.5D and will be implanted with the POD 26P AY FT and Group 2 will be made of 26 patients with corneal astigmatism lower than 1.0D in both eyes.
Interim analysis after the 12th patient of each group will have completed the last follow-up will be achieved to confirm the equivalence with the equivalence limit of 0.15.
The POD platform in 26 % (non toric version) is available since 2008 in the monofocal version and since 2012 in the toric one (POD 6P AY T, Ankoris®, PhysIOL).The so-called POD design is characterised by two symmetrical bifid haptics with opened loops that provide four points of support to ensure IOL stability in the capsular bag. The dual C-loop profile shortens the loops, thus improving the pliability of the implant during its injection through a micro-incision. These shortened loops should permit a clockwise or anticlockwise rotary motion and should facilitate the comfortable fitting of the implant orientation after unfolding without elastic-restoring torque. The double C-loop POD design offers 4 support points for the implant within the capsule and ensures its stability. The V-shape of the upper and lower haptics together with the flexibility of the implant allow the loop separation angle to be adjusted and ensure the most accurate adaptation to the capsular bag size. A finite element structural analysis of the implant showed that the elasticity at the distal part of the loop prevents the constraints from being transmitted onto the optical portion of the implant. The trifocal optic is associated to the POD platform and is made of 26 % raw material.
The rotational stability of this non toric version has been clinically investigated on 117 consecutive eyes 1 week, 3 weeks, 3 and 12 months after implantation. The absolute rotation of the lens averaged 2.5 ± 2.6°. The position of the center of the implant relative to the pupillary center expressed by a vector was 0.01 mm at 70°.
The investigational product (POD 26P AY FT) is CE labeled since January 2014. Main IOL features are:
The control product (POD 26P AY F) is CE labeled since 2010. Main IOL features are:
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| POD 26P AY FT | 26 patients with corneal astigmatism higher than 1.0D in both eyes and lower than 2.5D and will be implanted with the POD 26P AY FT |
| |
| POD 26P AY F | 26 patients with corneal astigmatism lower than 1.0D in both eyes will be implanted with the POD 26P AY F |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| POD 26P AY FT | Device | Routine cataract surgery |
| |
| POD 26P AY F |
| Measure | Description | Time Frame |
|---|---|---|
| Determine the equivalence of the glare | The primary endpoint is to show statistically equivalent outcomes on glare at the 3 months follow up visit. A significance level of p = 0.05 will be considered statistically significant. | 3 Months |
| Measure | Description | Time Frame |
|---|---|---|
| Measurement of far, intermediate and near visual acuity | The secondary objective is to measure far, intermediate and near visual acuity of the POD AY 26P FT with respect to the POD AY 26P F. | 6 Months |
| Refraction |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
The study population consists of patients undergoing routine cataract surgery. The study participants receive a bilateral implantation of trifocal intraocular lenses. Depending on the preoperative corneal astigmatism, the patients receive either non-toric trifocal IOLs (POD F) or toric trifocal IOLs (POD FT) in both eyes.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Francisco Poyales Galan, PhD | CEIC Hospital Clinical San Carlos | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital ClÃnico San Carlos | Madrid | 28040 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23352708 | Background | Chassain C, Pagnoulle C, Gobin L, Rozema J. [Evaluation of a new intraocular lens platform: centration and rotational stability]. J Fr Ophtalmol. 2013 Apr;36(4):336-42. doi: 10.1016/j.jfo.2012.04.012. Epub 2013 Jan 24. French. | |
| 23522584 | Result | Visser N, Bauer NJ, Nuijts RM. Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg. 2013 Apr;39(4):624-37. doi: 10.1016/j.jcrs.2013.02.020. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
Routine cataract surgery |
|
The secondary objective is to measure the refraction of the POD AY 26P FT with respect to the POD AY 26P F.
| 6 Months |
| Centration | The secondary objective is to measure the centration of the POD AY 26P FT with respect to the POD AY 26P F. | 6 Months |
| Rotational stability | The secondary objective is to measure the rotational stability of the POD AY 26P FT with respect to the POD AY 26P F. | 6 Months |
| Equivalence of the visual acuity and the contrast sensitivity | The secondary objective is to determine the equivalence of the visual acuity of the POD AY 26P FT with respect to the POD AY 26P F. | 6 Months |
| Equivalence of the visual acuity and the contrast sensitivity | The secondary objective is to determine the contrast sensitivity at far of the POD AY 26P FT with respect to the POD AY 26P F. | 6 Months |
| 23332253 | Result | de Vries NE, Nuijts RM. Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects. J Cataract Refract Surg. 2013 Feb;39(2):268-78. doi: 10.1016/j.jcrs.2012.12.002. |
| 23688874 | Result | Wolffsohn JS, Jinabhai AN, Kingsnorth A, Sheppard AL, Naroo SA, Shah S, Buckhurst P, Hall LA, Young G. Exploring the optimum step size for defocus curves. J Cataract Refract Surg. 2013 Jun;39(6):873-80. doi: 10.1016/j.jcrs.2013.01.031. |
| 23332118 | Result | Sheppard AL, Shah S, Bhatt U, Bhogal G, Wolffsohn JS. Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens. J Cataract Refract Surg. 2013 Mar;39(3):343-9. doi: 10.1016/j.jcrs.2012.09.017. Epub 2013 Jan 16. |
| 22969289 | Result | Cochener B, Vryghem J, Rozot P, Lesieur G, Heireman S, Blanckaert JA, Van Acker E, Ghekiere S. Visual and refractive outcomes after implantation of a fully diffractive trifocal lens. Clin Ophthalmol. 2012;6:1421-7. doi: 10.2147/OPTH.S32343. Epub 2012 Sep 3. |
| 22425363 | Result | Roensch MA, Charton JW, Blomquist PH, Aggarwal NK, McCulley JP. Resident experience with toric and multifocal intraocular lenses in a public county hospital system. J Cataract Refract Surg. 2012 May;38(5):793-8. doi: 10.1016/j.jcrs.2011.11.043. Epub 2012 Mar 15. |
| 21940140 | Result | Visser N, Nuijts RM, de Vries NE, Bauer NJ. Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation. J Cataract Refract Surg. 2011 Nov;37(11):2034-42. doi: 10.1016/j.jcrs.2011.05.041. Epub 2011 Sep 22. |
| 24075158 | Result | Bellucci R, Bauer NJ, Daya SM, Visser N, Santin G, Cargnoni M, Nuijts RM; Lisa Toric Study Group. Visual acuity and refraction with a diffractive multifocal toric intraocular lens. J Cataract Refract Surg. 2013 Oct;39(10):1507-18. doi: 10.1016/j.jcrs.2013.04.036. |
| 24355720 | Result | Alfonso JF, Knorz M, Fernandez-Vega L, Rincon JL, Suarez E, Titke C, Kohnen T. Clinical outcomes after bilateral implantation of an apodized +3.0 D toric diffractive multifocal intraocular lens. J Cataract Refract Surg. 2014 Jan;40(1):51-9. doi: 10.1016/j.jcrs.2013.06.026. |
| 23680631 | Result | Ferreira TB, Marques EF, Rodrigues A, Montes-Mico R. Visual and optical outcomes of a diffractive multifocal toric intraocular lens. J Cataract Refract Surg. 2013 Jul;39(7):1029-35. doi: 10.1016/j.jcrs.2013.02.037. Epub 2013 May 13. |
| 24203808 | Result | Knorz MC, Rincon JL, Suarez E, Alfonso JF, Fernandez-Vega L, Titke C, Kohnen T, Tucker S. Subjective outcomes after bilateral implantation of an apodized diffractive +3.0 D multifocal toric IOL in a prospective clinical study. J Refract Surg. 2013 Nov;29(11):762-7. doi: 10.3928/1081597X-20131021-06. |