Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| 2020-A02834-35 | Other Identifier | ID-RCB |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| URC-CIC Paris Descartes Necker Cochin | OTHER |
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia
Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia and impaired lung vasculature. Fetal lung growth may be stimulated by fetal endoscopic tracheal occlusion (FETO). In severe CDH, FETO may improve survival. In the moderate cases, the prematurity induced by the plug-unplug strategy limits the benefit from the lung growth induced by tracheal occlusion.
One of the main drawbacks of FETO is the need for in-utero reversal of tracheal occlusion by the balloon, as the current procedure involves re-establishment of patent airways either electively at 34 weeks' gestation or earlier if required, ideally at least 24 h before birth. Unfortunately, removal of the balloon is a difficult, invasive, and risky procedure. Furthermore, it requires a specialist team to be able to reverse the occlusion at all times. As a result, it is recommended that the patient stays close to a FETO center during the whole duration of the occlusion, which may limit the acceptability of FETO.
The Smart-TO balloon allows an easy, remotely controlled, and non-invasive reversal occlusion, so it allows to overcome issues related to the airway reestablishment. The technology solution is based on a magnetic valve that opens under the influence of the peripheral magnetic field around a magnetic resonance (MR) scanner. The opening of the valve induces the deflation of the balloon, which is then washed out by the fluid coming out from the lungs.
The purpose of this study is to make the proof of concept and to evaluate the safety of fetoscopic endoluminal tracheal occlusion (FETO) using Smart-TO device in fetuses with congenital diaphragmatic hernia and moderate to severe pulmonary hypoplasia. Secondary objectives include evaluation of prematurity, preterm premature rupture of membranes, lung growth, and survival at discharge in case of FETO with Smart-TO balloon.
FETO with Smart-TO balloon will be performed between 27 and 31wks + 6 days depending on the severity of pulmonary hypoplasia, according to the same technique that is used with the balloon usually used for FETO procedure. The unplug procedure will be performed between 34 and 34wks + 6 days or earlier if required. The patient will be asked to make a peripheral course around the MR scanner in order to open the magnetic valve and induce the deflation of the balloon. Ultrasound scan will be performed before and after the unplug procedure, in order to check the balloon did not deflate spontaneously at the time of the unplug, and to check the balloon deflates thanks to the magnetic fringe field of the MR scan. Expelling of the Smart-TO balloon outside the airways will be check at birth by a thorax X-ray.
Patients will be monitored during the whole duration of the study so serious unexpected or adverse reactions can be recorded.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervention | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FETO with Smart-TO balloon | Procedure | Fetal endoscopic tracheal occlusion using the Smart-TO balloon Unplug procedure by peripheral course around the MR scanner |
|
| Measure | Description | Time Frame |
|---|---|---|
| Deflation of the Smart-TO balloon after exposure to the fringe field of the MRI | No visualization of the balloon at ultrasound scan | Between 34 and 34+6 amenorrhea weeks |
| Expelling of the Smart-TO balloon outside the airways | Thorax X-ray of the neonate | At birth |
| Measure | Description | Time Frame |
|---|---|---|
| Serious unexpected or adverse reactions | Adverse reactions monitoring during the whole study duration | From date of inclusion until discharge date from hospitalization of newborn, up 15 months |
| Spontaneous deflation of the balloon |
Not provided
Inclusion Criteria:
Severe pulmonary hypoplasia defined as observed on expected 'lung-to-head ration' (O/E LHR) <25% irrespective of the liver position as measured between 27wks and 29wks + 6 days Or Moderate pulmonary hypoplasia defined as O/E LHR 25-34.9% (liver up or down) or O/E LHR 35-44.9% with liver up as measured between 30wks and 31wks + 6 days
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Anne-Gael CORDIER, MD, PhD | Assistance Publique - HĂŽpitaux de Paris | Study Chair |
| Nicolas SANANES, MD, PhD | University Hospital, Strasbourg, France | Study Chair |
| Alexandra BENACHI, MD, PhD | AH-HP | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| HÎpital BéclÚre | Clamart | 92140 | France | |||
| HĂŽpital BicĂȘtre |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 42335922 | Derived | Russo FM, Sananes N, Letourneau A, Devlieger R, Megier C, Lewi L, Huyn VTN, Aertsen M, Dumery G, Deprest J, Benachi A; SMART-TO consortium. Non-invasive removal of the Smart tracheal occlusion device for fetal congenital diaphragmatic hernia: a single-arm, open-label, phase 1 study. Lancet. 2026 Jun 23:S0140-6736(26)00664-1. doi: 10.1016/S0140-6736(26)00664-1. Online ahead of print. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D065630 | Hernias, Diaphragmatic, Congenital |
| ID | Term |
|---|---|
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D006548 | Hernia, Diaphragmatic |
| D000082122 | Internal Hernia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Ultrasound scan
| Between the FETO (27amenorrhea weeks) and the unplug procedure (34 amenorrhea weeks) |
| Prematurity | Gestational age at birth | At birth |
| Preterm premature rupture of the membranes (PPROM) | Event of PPROM and gestational age at PPROM | from date of inclusion until delivery, up to 37 amenorrhea weeks |
| Fetal lung growth | O/E LHR measurement | Before the unplug procedure |
| Survival at discharge | Neonate survival | From date of inclusion until discharge date from hospitalization of newborn, up to 6 months |
| Survival at 6 months of age | Neonate survival | 6 months after birth |
| Oxygen dependence | 6 months after birth |
| Le Kremlin-BicĂȘtre |
| 94270 |
| France |
| D006547 | Hernia |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |