Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The Intelligent Cardiopulmonary Rehabilitation System (ICRS) was developed to automatically control the resistance of pedaling in combination with the conventional stationary bike by monitoring the user's heart rate for clinical use. To test its feasibility, 8 healthy participants were recruited to complete 12 sessions (3 times per week for 4 weeks) of indoor cycling on the stationary bicycle with ICRS. Subjects were received cardiopulmonary exercise testing (CPET) before and after the biking sessions.The 60-80% of heart rate reserve (HRR) of each participant was determined according to their first CPET results. The algorithm of ICRS was designed to enable the bicycle to adjust its training intensity in accordance with the subject's 60-80% HRR which was detected by wearing a wristband heart rate monitor during cycling. With ICRS, the participants' heart rates during training were expected to fall in the 60-80% HRR, increasing their cardiopulmonary fitness after 12 sessions of indoor cycling.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Indoor cycling training | 8 subjects were asked to complete indoor cycling training, 3 times a week for 4 weeks. Each session of training consisted of 30-minute stationary biking (5 minutes of warm-up, 20 minutes of training and 5 minutes of cooldown). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ICRS | Device | The ICRS enables a stationary bike to automatically adjust the pedaling resistance (i.e. training intensity) according to the subject's heart rate. The training intensity is determined by monitoring whether the subject is able to maintain a 50-70 cycles/min cadence with 60-80% HRR. Subjects heart rate was detected by a wearable device for heart rate, synching with the stationary bike. |
| Measure | Description | Time Frame |
|---|---|---|
| Peak oxygen consumption (VO2-peak) | Oxygen consumption (VO2- peak) were measured during our cardiopulmonary test (with a incremental biking and a gas analyzer). The workload was increased at a ramp rate of 5-10 W/min. A cadence at 50~70 rpm was to be maintained. | 4 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Peak workload | The peak workload is measured during a the cardiopulmonary exercise test with a ramped stationary biking. | 4 weeks |
| Compliance of training during the training sessions | The percentage of time that a subject's heart rate falls in his or her estimated 60-80% HRR over the 12 sessions of training. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Healthy subjects
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Wan Fan Hospital | Taipei | Taiwan |
Not provided
Not provided
Not provided
Not provided
|
| 4 weeks |
| Averaged workload during the training sessions | The averaged workload (watt) that a subject paddled on the stationary bike over the 12 sessions of training. | 4 weeks |