Traditional temporary pacing catheter insertion by intracavitary electrocardiogram (IC-ECG) monitoring which only monitoring tip polar, the negative one. The investigators modified the technique by monitoring both negative and positive polar which will be precisely locating catheter tip and indicating the direction of the catheter tip.
Extensively used temporary pacing catheter tip has two electrodes which are about 1 cm apart. Distal electrode is negative (-) and active, proximal electrode is positive (+) and indifferent.
Investigators use both distal (-) and proximal (+) electrodes which can be attached to any two of the V leads, record as V(-) and V(+). Monitoring positions of the electrodes by V(-) and V(+) could provide more information about the tip position. Comparing the QRS amplitudes between V(-) and V(+), when catheter tip enters right ventricle chamber: the case of V(-) > V(+) infers tip toward apex ventricle wall ; conversely, the case of V(-)\
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Non-floating catheter | When using non-floating catheter. |
| |
| Floating catheter | When using floating catheter. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Temporary transvenous cardiac pacing | Procedure | Transvenous temporary pacemaker insertion by modified IC-ECG monitoring. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Pacer leads location | Satisfy location is in the apex of the right ventricle. | One day. |
| Catheter-related complications | Pacing catheter related complications: tip dislocation caused pacemaker malfunction, myocardial injury, perforation, death. | One month. |
| Measure | Description | Time Frame |
|---|---|---|
| Other complications | Complications not relate to pacing catheter. | One month. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients need emergency or selective temporary pacing.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Meng Liu, MD | Contact | +8615084858606 | 183578012@qq.com | |
| Xiaotong Han, MD | Contact | +8613725870299 | 744953695@qq.com |
| Name | Affiliation | Role |
|---|---|---|
| Xiaotong Han, MD | Hunan Provincial People's Hospital | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hunan Provincial People's hospital | Recruiting | Changsha | Hunan | 410000 | China |
Any date will share if appropriate.
Two years.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001919 | Bradycardia |
| D013575 | Syncope |
| D054537 | Atrioventricular Block |
| D013610 | Tachycardia |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D014474 | Unconsciousness |
| D003244 | Consciousness Disorders |
| D019954 | Neurobehavioral Manifestations |
| D009461 | Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D006327 | Heart Block |
| D000075224 | Cardiac Conduction System Disease |
Not provided
Not provided