Objetive: to assess the efficacy of the occipito-atlas-axis cervical manipulation technique to correct ocular divergence in subjects with exophoria.
Design: quantitative, experimental, longitudinal and prospective study.
Subjects: subjects over 18 years of age, with exophorias, without heterotropies and who do not present a contraindication to cervical manipulation.
Methods:Subjects with this ocular mobility dysfunction are going to be evaluated objectively with the Alternate Cover Test. The ocular deviation will be measured at 40 cm and at 4 meters. The individuals who were part of the experimental group underwent the OAA manipulation technique, and to those who were part of the control group a placebo maneuver. Two measurements were taken from this moment, one immediately after the execution of the technique and another one week later.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| cervical manipulation | Experimental | The objective of this technique is to restore joint mobility between the joints of the occipital, first (atlas) and second cervical vertebra (axis). It is a technique performed in rotation on a vertical axis that passes through the odontoid process of the axis, without placing flexion or extension, and with very slight sidebending; it is done bilaterally. |
|
| Cranial Listening | Active Comparator | Cranial palpation maneuver |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| O-A-A | Procedure | patient is supine, and the therapist stands on the side to be manipulated. The cranial hand of the therapist globally grasps the patient's skull and turns the patient's neck on that same side. The caudal hand is placed on the patient's face. The technique is performed by an impulse in pure rotation on the side that the cervical region is rotated, with a helical movement. |
| Measure | Description | Time Frame |
|---|---|---|
| exophoria with cover test at 40 cm | The exophoria will be evaluated in prismatic diopter. Using the cover alternate test, therapist will measure with a prism ruler the diopters that the subject requires to balance eye movement and that the eye does not move from the outside to the inside when looking at an object at 40 cm. | Changes from baseline to moment after intervention |
| exophoria with cover test al 4 m | The exophoria will be evaluated in prismatic diopter. Using the cover alternate test, therapist will measure with a prism ruler the diopters that the subject requires to balance eye movement and that the eye does not move from the outside to the inside when looking at an object at 4 meters. | Changes from baseline to moment after intervention |
| Measure | Description | Time Frame |
|---|---|---|
| exophoria with cover test at 40 cm (2) | The exophoria will be evaluated in prismatic diopter. Using the cover alternate test, therapist will measure with a prism ruler the diopters that the subject requires to balance eye movement and that the eye does not move from the outside to the inside when looking at an object at 40 cm. | Changes from baseline to 1 week after intervention |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Lourdes M Fernández-SeguÃn, PhD | University of Seville | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Lourdes M Fernández-SeguÃn | Seville | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 37347984 | Derived | Fernandez-Seguin LM, Peinado-Asensio M, Diaz-Mancha JA, Cortes-Vega MD, Heredia-Rizo AM. Short-Term Effect of Spinal Manipulation on the Magnitude of Exophoria in Adults Who Are Asymptomatic: A Randomized Controlled Trial. Phys Ther. 2023 Aug 1;103(8):pzad069. doi: 10.1093/ptj/pzad069. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D005099 | Exotropia |
| D015835 | Ocular Motility Disorders |
| D013285 | Strabismus |
| ID | Term |
|---|---|
| D003389 | Cranial Nerve Diseases |
| D009422 | Nervous System Diseases |
| D005128 | Eye Diseases |
| D002493 | Central Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| cranial listening | Procedure | The patient is in the supine position, and the therapist sitting at the head of the patient. The therapist places his hands on the head of the patient, the thumbs touch each other, without touching the vault cranial. A perception of the cranial rhythm is carried out passively. |
|
| exophoria with cover test al 4 m (2) | The exophoria will be evaluated in prismatic diopter. Using the cover alternate test, therapist will measure with a prism ruler the diopters that the subject requires to balance eye movement and that the eye does not move from the outside to the inside when looking at an object at 4 meters. | Changes from baseline to 1 week after intervention |