This study is a prospective healthy human volunteer wear study to evaluate the safety and performance of the StatLock™ Catheter Stabilization Device and the StatLock™ stabilization device Accessory (Foam Strip) and to meet the design input requirements.
This is a healthy human wear study of a minimum of 100 study participants who will wear the StatLock™ Catheter Stabilization Device and the StatLock™ stabilization device accessory (Foam Strip). Participants will report to the research center, on Day 0 to have their skin assessed by the investigator, clinician, and/or designee. On Day 0 the participants will have the StatLock™ Catheter Stabilization Devices and the foam strip applied. There will be 4 separate StatLock™ devices being tested, which will be randomly applied to the participants on their inner (ventral) forearms. Each participant will have 2 separate devices applied, one to each arm. Those participants who have the StatLock ™ Arterial Plus, StatLock™ Dialysis II, or the StatLock IV Select , will also have the Foam Strip applied.
The participant will also wear a dressing over top of a StatLock™ compatible catheter, which will be connected to an extension set. For this study, the catheter will not be inserted into the study participant but instead will be shortened or modified and placed on the skin and secured with the StatLock™ Stabilization Device. The catheter tip will be marked with indelible ink, to assess for any catheter movement. The use of the catheters, extension set, and the dressing represents how the device would be used in a clinical setting.
Once the devices are applied the participant will have the skin assessed (using a modified Draize Scale) by the investigator, clinician, and/or designee on Day 0. The participant will wear the devices at home for 1 week and will return on Day 7 for a skin assessment, evaluation of pad and foam strip lift, and catheter movement, evaluation of pain, and removal of the devices by the investigator, clinician, and/or designee. On Day 8, there may be a phone call and/or video call with the participant to review the skin condition of the site where the device was removed from.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Healthy volunteers | There will be 4 separate StatLock™ devices being tested, which will be randomly applied to the participants on their inner (ventral) forearms. Each participant will have 2 separate devices applied, one to each arm. Those participants who have the StatLock ™ Arterial Plus, StatLock™ Dialysis II, or the StatLock IV Select, will also have the foam strip applied. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| StatLock™ Catheter Stabilization Device and the StatLock™ stabilization device accessory (Foam Strip) | Device | Each participant will have 2 separate devices applied, one to each arm, with or without a Foam Strip.The participant will also wear a dressing over top of a StatLock™ compatible catheter, which will be connected to an extension set. For this study, the catheter will not be inserted into the study participant but instead will be shortened or modified and placed on the skin and secured with the StatLock™ Stabilization Device. The use of the catheters, extension set, and the dressing represents how the device would be used in a clinical setting. |
| Measure | Description | Time Frame |
|---|---|---|
| Percent lift of the StatLock™ Catheter Stabilization Device Pad at Day 7 | Device pad lift will be assessed using a Visual Analog Scale, ranging from 0 - Fully adhered to 100 - Device absent. When the percent lift at day 7 is >50%, it is considered a failure. | Day 7 |
| Percent of Device Movement of the StatLock™ Catheter Stabilization Device at Day 7 | The percent of device movement of the catheter will be assessed using a Visual Analog Scale from 0 (no movement) to 100 (completely displaced). | Day 7 |
| Ease of Removal of the StatLock™ Catheter Stabilization Device | Ease of removal will be assessed using a 100 mm Visual Analog Scale where 0 is very easy to remove and 100 is very difficult to remove. | Day 7 |
| Percent of participants with erythema score ≥ 2 | Erythema score will be assessed using a modified Draize scale with scores ranging from 0 to 3, as follows: 0 - no visible reaction; 0.5 - Doubtful or negligible erythema reaction; 1.0 - mild or just perceptible macular erythema reaction in a speckled/follicular, patchy or confluent pattern (slight pinking); 2.0 - Moderate erythema reaction in a confluent pattern (definite redness); 3 - Strong or brisk erythema reaction that may spread beyond the test site). | Day 7 |
| Measure | Description | Time Frame |
|---|---|---|
| Percent lift of the Foam Strip (StatLock™ Stabilization Device Accessory) at Day 7 | The percent lift of the foam strip will be assessed using a Visual Analog Scale ranging from 0 (fully adhered) to 100 (device accessory absent). | Day 7 |
| Ease of Removal of the StatLock™ Stabilization Device Foam Strip |
| Measure | Description | Time Frame |
|---|---|---|
| Rate of StatLock™ Catheter Stabilization device-related adverse events | Rate of device-related adverse events. | Day 0 to Day 8 |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Potential participants will be recruited from healthy volunteer participant pools identified and/or held by the study site(s).
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Casser, MD | TKL Research, Inc. | Principal Investigator |
| Gary Grove, PhD | Dermico, LLC | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| TKL Research, Inc | Fair Lawn | New Jersey | 07410 | United States | ||
| Dermico, LLC |
Not provided
Not provided
Not provided
Not provided
|
|
The ease of removal will be assessed using a 100 mm Visual Analog Scale where 0 is very easy to remove and 100 is very difficult to remove. |
| Day 7 |
| Level of pain upon removal of the StatLock™ Catheter Stabilization Device | Pain upon removal of the device will be assessed using a 100 mm Visual Analog Scale where 0 is no pain and 100 is unbearable pain. | Day 7 |