The Early neo2 registry will study up to 500 patients treated with the updated Boston Acurate neo2 TAVI prosthesis at various European hospitals. The data is gathered from routine healthcare and there are no study-mandated additional procedures. The main endpoint is a combined efficiency and safety endpoint after 30 days. Imaging data (echocardiography, computed tomography and aortography) will be analysed centrally by a core lab.
Background and rationale The Boston Scientific Acurate neo2 TAVI prosthesis was launched commercially in Europe in September 2020 as a successor to the original Acurate neo prosthesis. Modifications include an added sealing skirt. The original Acurate neo failed to reach non-inferiority to other TAVI prostheses in two randomized trials. There is a need to gather initial safety and efficacy data from this next generation prosthesis, as there is no larger dataset presented after the CE-mark study of the Acurate neo2.
Project objectives To gather initial safety and efficacy data in the initial up to 500 consecutive patients treated with the Acurate neo2 in various European sites.
Karolinska will be the coordinating center for data collection.
Methods Data will be collected in an anonymous form and sent to Karolinska for compilation and statistics. Data collection will continue until 500 patients are reached (April, 2021).
Statistics Standard descriptive statistics will be used for the main results. For the comparison to SCOPE data (with the original Acurate neo prosthesis) on postoperative aortic insufficiency, standard statistical methods will used (Fishers exact test for categorical variables, and t-test for continuous measurements such as amount of regurgitation by videodensitometry).
Core lab studies The core lab analyses will be performed at CORRIB in Galway (Prof. Serruys et al).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Boston Scientific Acurate neo2 TAVR device | Device | The newest generation of the Acurate neo2 TAVR device, launched in Europe in 2020. |
| Measure | Description | Time Frame |
|---|---|---|
| MACE | any of
| 30 days |
| Measure | Description | Time Frame |
|---|---|---|
| Rate of Postoperative aortic insufficiency more than mild by transthoracic echo | Core-lab analysis of the postoperative transthoracic echo for aortic insufficiency: percentage of patients with more than mild insufficiency | Within 7 days of procedure |
| Rate of Postoperative aortic insufficiency more than mild by aortography |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
The first 500 consecutive patients treated with the Acurate neo2 from up to 15 European sites which have started using the Acurate neo2.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Andreas Rück, MD PhD | Karolinska University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Rigshospitalet | Copenhagen | Denmark | ||||
| Kerckhoff Klinik |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001024 | Aortic Valve Stenosis |
| ID | Term |
|---|---|
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Core-lab analysis of the aortogram in the end of the procedure for quantification of aortic insufficiency (videodensitometry): rate of patients with more than mild insuffiency |
| Same day as procedure |
| Postoperative aortic valve gradients | Aortic prosthesis mean gradient (mmHg) on postoperative transthoracic echocardiogram | Within 7 days of procedure |
| Rate of major acute procedural complications | Intraprocedural complications such as valve embolization, need for second valve, anular rupture | Same day as procedure |
| Procedural contrast use | The average amount of contrast in ml per procedure | Same day as procedure |
| Bad Nauheim |
| Germany |
| Lund University Hospital | Lund | Sweden |
| Karolinska University Hospital | Stockholm | Sweden |
| D014694 |
| Ventricular Outflow Obstruction |