Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Total knee arthroplasty (TKA) is one of the success stories of modern surgery, providing high patient satisfaction outcomes. Total knee prostheses are generally composed by a femoral component articulating on a polyethylene insert and a tibial tray.
Recently there has been particular attention on the component material; traditionally femoral components are made of cobalt alloys while tibial baseplates are made, in the great majority of cases, of metallic materials, but also polyethylene versions are available. There has been a degree of acceptance in some countries that metal related pathology may exist as demonstrated by the Australian Arthroplasty register where metal hypersensitivity was reported as the fifth most common cause for revision hip arthroplasty 2012 report, making up for 5.9% of all revisions. The wording was subsequently changed from "metal sensitivity" to "metal related pathology" in the 2014 report with 0.5% of all revision total hip arthroplasties (THA) associated with this term. The same change in terminology was used for TKA with metal sensitivity as a cause for revision in 1.3% of revisions in 2012 and in 2014, 1.8% of revision TKAs attributed to "metal related pathology" . The overall revision rate was 3.45% after 10 years in 396.472 TKAs, suggesting a revision rate of 0.06-0.32% secondary to metal or cement allergies. Up to today there is no question that metallic implants may generate wear debris that cause local reactions. This local reaction is not dose related nor predictable and therefore not purely due to the toxic effect of the debris but possibly due to an immunological host process. Hypersensitivity to metal undoubtedly exists but it cannot be stated at the moment to be an allergic reaction. To prevent issues arising due to metal related pathology, alternative solutions to conventional chrome cobalt material have been proposed, for example ceramic component or implant coating. In particular, TiNbN coating has been proposed by most companies thanks to its excellent biological properties. Preclinical studies have showed a high scratch resistance and low coefficient of friction, more resistance to fretting corrosion, reduction of wear, lower ion release rates and low fatigue cycle, as described in the review of Hove. Clinically, cohort of studies of TiN-coated implants showed an overall survival exceeding 90% with a follow-up of 15 to 77 months and good clinical outcomes. No reports of adverse effects related to TiN coating of CoCrMo knee implants have been showed. There are few studies that compared TiN-coated implants with the same uncoated version. Thienpont, comparing TiN-coated and uncoated CoCrMo implants, showed similar clinical and radiological outcomes at short-term follow up in both patients groups .
Overall we can conclude that in literature no adverse events have been reported concerning the TiNbN coating and in particular it has been showed that the coating doesn't not affect the performance of the device if compared with the same uncoated version.
The aim of this study is to evaluate the long term clinical and radiological performance of GMK Sphere total knee component, coated version.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Ion released group | First 30 patients will be assessed for metalic ion released by blood sample. the patients will be monitored until 10 years follow-up for long term performance of the device |
| |
| Other group | The remaining 125 patients will be not assessed for metalic ion released; they will be monitored until 10 years follow-up for long term performance of the device |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| blood sample | Diagnostic Test | preoperative and at 6 months and 1 year follow-up after the surgery the patients will take a blood sample |
|
| Measure | Description | Time Frame |
|---|---|---|
| Long term performance | Device survival will be assessed by Kaplan Maier curve | 10 years |
| Measure | Description | Time Frame |
|---|---|---|
| Clinical performance | Clinical performance will be assessed through the NEW KSS score collected during preoperative and follow-up visits. The score is divided in subscale: objective (0-75), Symptoms (0-25), Satisfaction (0-40), Expectation (0-15), Functional Activities (0-30), high scores indicating good outcomes. | 6 months, 1, 5 and 10 years after surgery |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Sample size calculation has been performed according to one proportion test comparing expected survival at 10 year of 96.3%[5] with the bench mark value defined by ODEP Panel for a total knee arthroplasty at 10 yrs of 90%. With a significance level of 5% and a power of 80%, 141 patients are necessary to show a non-inferiority test. Considering a lost to follow-up rate of 10%, 155 patients will be recruited.
B. Bordini, C. Ancarani, and D. A. Fitch, "Long-term survivorship of a medial-pivot total knee system compared with other cemented designs in an arthroplasty registry," Journal of orthopaedic surgery and research, vol. 11, no. 1, p. 44, 2016
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Franco Parente, Dr | Contact | +390248785210 | franco.parente@grupposandonato.it |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| IRCCS Istituto Ortopedico Galeazzi di Milano Sede di via Monreale18 (Istituto Clinico San Siro) | Recruiting | Milan | MI | 20148 | Italy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001800 | Blood Specimen Collection |
| ID | Term |
|---|---|
| D013048 | Specimen Handling |
| D019411 | Clinical Laboratory Techniques |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
| Radiological performance | standard x-ray exam performed preoperatively and postoperatively before discharge from hospital and during follow-up visits | (1, 5 and 10 years after surgery |
| Retropatellar pain | Kujala score collected during preoperative visit and follow-up visit. Each scale ranges from 0 to 100 with high scores indicating good outcomes. | 6 months and 1, 5 and 10 years after surgery |
| Ion release rate | blood level of ions Co, Cr and Ni in a subgroup of 30 patients | preoperative, 6 months and 1 year visits |
| Activity level after surgery | UCLA Activity score collected during preoperative visit and follow-up visit. 1-10 scale with 1 less active, to 10 more active. | 6 months and 1year after surgery |
| Rate of complications | collection of all adverse events occurred | up to 10 years after surgery |
| D011677 | Punctures |
| D013514 | Surgical Procedures, Operative |
| D008919 | Investigative Techniques |