Pacemapping is an essential tool during ablation of idiopathic PVC and VT. Automated template matching has been shown to have a significant influence on PVC ablation procedures, but the PASO module of CARTO3 has not been studied in a randomized trial. The Aim of this study is to evaluate the additional benefit of PASO template matching on PVC ablation procedure with regard to procedural parameters and outcome when compared with conventional pace mapping. A total of 144 pts will be randomised in a 1:1 fashion to PVC ablation guided by conventional pacemapping vs PVC ablation guided by PASO pacemapping. Patients will be follow up with Holter-ECG and TTE after 3 and 12 months.
Introduction / Rationale Premature ventricular contractions (PVC) in the otherwise healthy heart are not associated with increased mortality in the absence of a short coupling interval or a compromised left ventricular function and do not require treatment if asymptomatic . Symptomatic idiopathic PVC or VT on the other hand can burden patients with recurring palpitations, dizziness, dyspnea and possibly syncope in cases of fast VT. A reversible decrease in left ventricular function as a result of a high PVC burden has been reported even in patients with no underlying cardiomyopathy . Radiofrequency Ablation (RFA) is a well-established method to treat idiopathic PVC and VT, and is associated with satisfying long-term results. Pacemapping is an essential tool during ablation of idiopathic PVC and VT. Automated template matching has been shown to have a significant influence on PVC ablation procedures, but the PASO module of CARTO3 has not been studied in a randomized trial.
Aim of the study To evaluate the additional benefit of PASO template matching on PVC ablation procedure with regard to procedural parameters and outcome when compared with conventional pace mapping.
Hypothesis PASO guidance during PVC / VT ablation has a significant impact on outcome after catheter ablation of idiopathic PVC / VT.
Study design This study is planned as a two-center trial. All patients presenting for de novo ablation of idiopathic ventricular arrhythmia will be included and randomized in a 1:1 fashion in this open-label, two-center, randomized controlled trial.
In patients randomized to the PASO / intervention group pacemapping will be guided by automated template matching of the PASO module of CARTO3.
In patients randomized to the conventional / control group conventional pacemapping will be employed.
A 3D electroanatomic geometry including activation mapping will be acquired in all patients using CARTO3. Sedation, catheters and monitoring during and after CA, will not differ from standard clinical practice and will be the same for both groups.
Follow-up after 3 and 12 months will assess PVC burden by Holter ECG, symptoms through a standardized questionnaire and LV function by TTE
Duration and study size Based on prior findings ("Impact of Automated Template Matching during PVC Ablation: Results from a Randomized Controlled Trial" Lüker et al. ESC 2014 poster presentation) 144 pts have to be randomized to detect a significant difference with respect to ablation success at follow-up (alpha 0.05, power 80%).
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| conventional pace mapping | Active Comparator | Conventional PVC pace mapping without visual guidance of PASO |
|
| PASO pace mapping | Experimental | PASO pace mapping with visualisation in CARTO3 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PASO Pacemapping | Procedure | Using the PASO pacemapping visualisation module of CARTO3 |
| |
| Measure | Description | Time Frame |
|---|---|---|
| PVC recurrence in Holter ECG | Assessment of PVC as % of total number heart beats in a 24 hours Holter ECG | 12 weeks after ablation procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Symptomatic recurrence | recurrence of PVC according to the patients symptoms | between 3 and 12 months after ablation |
| LV ejection fraction assessment (%) | Change in LV ejection fraction after ablation (%) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospital Cologne | Recruiting | Cologne | 50937 | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D018879 | Ventricular Premature Complexes |
| D009202 | Cardiomyopathies |
| D006333 | Heart Failure |
| D017180 | Tachycardia, Ventricular |
| ID | Term |
|---|---|
| D005117 | Cardiac Complexes, Premature |
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
1:1 simple randomisation
Not provided
Not provided
Patients will be masked to treatment arm. Investigator performing statistical analysis and adjudicating outcomes will be masked to treatment arm
| Conventional Pacemapping |
| Procedure |
without visualisation in 3D mapping |
|
| between 3 months and 12 months after ablation |
| Procedure duration | Procedure duration (min) | From groin puncture to sheath removal |
| Prcedural fluoroscopy parameters | Fluoroscopy dose (Gy x cm2) and time (min) | From groin puncture to sheath removal |
| Procedural ablation parameters | Number of RF lesions (n) and acute ablation success (cessation of PVC) | From groin puncture to sheath removal |
| D000075224 | Cardiac Conduction System Disease |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D013610 | Tachycardia |