Cardiac resynchronization therapy (CRT), or atrial-synchronized biventricular (BiV) pacing, is an FDA-approved device therapy option for heart failure (HF) patients with reduced left ventricular ejection fraction and electrical dyssynchrony. A traditional CRT device has pacing leads implanted within the right atrium (RA), the right ventricle (RV), and within a coronary vein overlying the lateral or posterior left ventricle (LV). Within the past decade, various multi-center randomized controlled trials have reported improved quality of life, aerobic exercise capacity, LV systolic function and structure, as well as decreased hospitalization rates and mortality among patients with HF. Despite improvements in CRT technology with multipoint pacing, quadripolar leads, and adaptive pacing algorithms, approximately 30% of patients do not clinically benefit and are considered non-responders. This study looks to optimize CRT device programming in patients considered non-responders to CRTusing information obtained from standard ECG machines, and to assess acute and chronic effects of CRT optimization using cardiac magnetic resonance imaging (CMR).
This is a prospective, randomized study designed to evaluate if CRT device optimization, guided by electrocardiography, improves cardiac function and clinical outcomes among patients considered non-responders to CRT. All patients will have electrocardiographic assessment of electrical dyssynchrony at a range of device settings using standard ECG machines. All patients will then have a baseline CMR study at baseline CRT programming, underlying rhythm, and optimal settings derived from the electrocardiographic assessment to assess acute effects of CRT optimization on mechanical synchrony, LV regional wall motion, and LV structure/ function. To assess chronic effects of CRT optimization, patients will be randomized in a 1:1 ratio after baseline CMR to either the active comparator arm (baseline CRT programming), or the experimental arm (CRT device programmed to optimal settings derived from the electrocardiographic assessment). Patients will be blinded to randomization. After 6 month, all patients will return for follow up CMR study to assess chronic effects. After follow up CMR imaging, the active comparator group will crossover to the experimental group. After 12 months, all patients will return for follow up echocardiogram to further evaluate the chronic effects of CRT optimization.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Baseline CRT programming | Active Comparator | The comparator arm patients will remain at baseline CRT programming for the first 6 months, and then will crossover to the experimental arm and CRT device will be programmed to optimal settings derived from the electrocardiographic assessment for the following 6 months. |
|
| Electrocardiography-guided optimal CRT programming | Experimental | The experimental arm patients will have CRT device programmed based on the electrocardiographic assessment for 12 months. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Programming of CRT device settings | Device | Reprogramming of CRT device to maximize the benefit derived from the electrocardiographic assessment. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Acute changes in left ventricular mechanical synchrony in study population | Acute changes, measured by cardiac magnetic resonance imaging, in left ventricular mechanical synchrony at underlying rhythm, baseline CRT programming, and optimal programming derived from electrocardiographic assessment in all patients. | During Baseline Assessment |
| Acute changes in left ventricular regional wall motion in study population | Acute changes, measured by cardiac magnetic resonance imaging, in left ventricular wall motion at underlying rhythm, baseline CRT programming, and optimal programming derived from electrocardiographic assessment in all patients. | During Baseline Assessment |
| Acute changes in left ventricular end-diastolic volume in study population | Acute changes, measured by cardiac magnetic resonance imaging, in left ventricular end-diastolic volume at underlying rhythm, baseline CRT programming, and optimal programming derived from electrocardiographic assessment in all patients. | During Baseline Assessment |
| Acute changes in left ventricular end-systolic volume in study population | Acute changes, measured by cardiac magnetic resonance imaging, in left ventricular end-systolic volume at underlying rhythm, baseline CRT programming, and optimal programming derived from electrocardiographic assessment in all patients. | During Baseline Assessment |
| Chronic changes in left ventricular mechanical synchrony | Chronic changes, measured by cardiac magnetic resonance imaging and echocardiography, in left ventricular mechanical synchrony between the experimental and active comparator group. | Baseline to 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Change in 6 Minute Hall Walk (6MHW) | Comparison between experimental arm and active comparator arm in 6MHW | Baseline to 12 months |
| Change in Kansis City Cardiomyopathy Questionnaire (KCCQ) | Comparison between experimental arm and active comparator arm in KCCQ. Scores are scaled 0-100. Higher scores indicate better outcomes. |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation in electrical dyssynchrony and left ventricular function in study population | Changes in electrical dyssynchrony, measured by electrocardiography, and correlation to change in left ventricular function, measured by cardiac magnetic resonance and echocardiographic imaging, in all patients. | Baseline to 12 months |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Alan J Bank, MD | Allina Heath System | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Minneapolis Heart Institute - Abbott Northwestern Hospital (MHI West) | Minneapolis | Minnesota | 55407 | United States | ||
We do not plan to share IPD with other external researchers.
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | May 28, 2021 | Mar 2, 2026 | Prot_000.pdf |
Not provided
| ID | Term |
|---|---|
| D054143 | Heart Failure, Systolic |
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Parallel (with 6 month crossover) 1:1 randomization - active comparator and experimental arm (note: at 6 month, the active comparator arm will crossover to the experimental arm)
Not provided
Not provided
Patients blinded to which group they are randomized and how their CRT device is programmed during the study. Individuals (readers) who perform cardiac magnetic resonance and echocardiographic imaging measurements blinded to patient randomization and CRT programming.
| Chronic changes in left ventricular regional wall motion | Chronic changes, measured by cardiac magnetic resonance imaging and echocardiography, in left ventricular regional wall motion between the experimental and active comparator group. | Baseline to 12 months |
| Chronic changes in left ventricular end-diastolic volume | Chronic changes, measured by cardiac magnetic resonance imaging and echocardiography, in left ventricular end-diastolic volume between the experimental and active comparator group. | Baseline to 12 months |
| Chronic changes in left ventricular end-systolic volume | Chronic changes, measured by cardiac magnetic resonance and echocardiographic imaging, in left ventricular end-systolic volume between the experimental and active comparator group. | Baseline to 12 months |
| Baseline to 12 months |
| United Heart & Vascular Clinic - Nasseff Specialty Center (MHI East) |
| Saint Paul |
| Minnesota |
| 55102 |
| United States |