Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study examines if acupuncture or TENS of P-6 and St-36 acupoints has a measurable effect on gag tolerance.
The gag reflex is a normal protective mechanism, and portion of the population has an exaggerated reflex that can present major problems in dentistry as well as endoscopy. Early studies with acupuncture have been promising, but these studies are limited as has not been a way to objectively measure the response to gag reflex. Recent work by Drs. Karibe and Goddard has determined a novel way of measuring gag reflex in healthy subjects, which makes it possible to study the effects of an intervention on gag reflex.
Acupuncture has been demonstrated to be effective for treating gag reflex, but this effect has not been objectively demonstrated using this novel method. As such, this study investigates the effect of acupuncture against placebo on gag reflex. Practically speaking, these findings are unlikely to be of high value since the availability of acupuncturists at dental offices is limited. For this reason, the investigators added a third arm to evaluate the use of a transcutaneous electrical nerve stimulator (TENS) device on the same acupuncture points as a treatment intervention to see if this is non-inferior to acupuncture. TENS is an FDA regulated treatment for the treatment of pain, and has been 510K cleared for other uses including nausea. The placebo arm uses a TENS device that has the wire severed, so that the light will continue to blink but no current will be applied.
60 total subjects will be recruited and randomized into one of these three groups: acupuncture, TENS and Sham-TENS.
Passive EKG readings will be collected using the FirstBeat Bodyguard 2, which is a 2-lead EKG device that the subject will wear during the study. This is to later evaluate vagal tone by analyzing the spectral analysis of heart rate variability.
Once this device is affixed to the front of the patient's chest, the gag reflex will be measured. The subject will then undergo the appropriate treatment (acupuncture, TENS or Sham-TENS for a total of 20 minutes, with a subsequent gag reflex measurement. The subject will then rest for at least 5 minutes at the end of the study to collect final EKG data, then given a gift card for her time.
It is the hypothesis of the investigators that the treatments will increase gag tolerance in the following stepwise manner: Sham-TENS < TENS < Acupuncture
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Acupuncture | Experimental | Sterile needles are inserted into acupuncture points P-6 and St-36 bilaterally and retained for a total of 20 minutes. Halfway through the treatment, the needles are manipulated in order to re-create the acupuncture sensation. The needles are removed after 20 minutes of treatment prior to the second gag measurement. |
|
| TENS | Experimental | Gel pads are affixed to the acupuncture points P-6 and St-36, bilaterally. The amplitude of the TENS device will be gradually increased up to a maximum setting of 8/10, with the subject asked to notify the examiner as soon as any sensation is noticed. Once a gentle buzzing sensation is noticed, the amplitude will be reduced slightly for comfort and then the device will remain for the duration of 20 minutes. The pads are then removed prior to the second gag reflex measurement. |
|
| Sham-TENS | Placebo Comparator | For the sham-TENS group, the protocol is identical to the TENS group, however the electrical wires have been severed and re-attached in the control unit. As such, the unit will flash a light but there will be no current delivered. The subject is told that no sensation is required. The amplitude will be turned up to a maximum setting of 8/10 and left there for 20 minutes, then the device turned off and pads removed. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Acupuncture | Procedure | Acupuncture of acupoints P-6 and St-36 |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Insertion length | A standard saliva ejector with a stopper made of heavy-body addition silicone impression putties is inserted into the participants' mouth at the maxillary central incisor, and gradually guided down the participant's throat along the palate. The participants are asked to inform the examiner when their maximum tolerance has been reached by pushing a button that beeps. The examiner then stopped inserting the saliva ejector, remove it, and measure the insertion distance of the saliva ejector from the maxillary central incisor using digital calipers. This distance is recorded as an index of the gag reflex. | immediately after procedure |
| Severity of gag reflex | Subjects are also be asked to report the severity of their gagging on a scale of 1-10, with 1 representing the minimum and 10 representing the maximum | immediately after procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Andrew Shubov, MD | University of California, Los Angeles | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of California, Los Angeles | Los Angeles | California | 90095 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Feb 27, 2021 | Mar 16, 2021 | 1 |
| ID | Term |
|---|---|
| D005683 | Gagging |
| ID | Term |
|---|---|
| D012817 | Signs and Symptoms, Digestive |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D015670 | Acupuncture Therapy |
| D004561 | Transcutaneous Electric Nerve Stimulation |
| ID | Term |
|---|---|
| D000529 | Complementary Therapies |
| D013812 | Therapeutics |
| D004599 | Electric Stimulation Therapy |
| D026741 | Physical Therapy Modalities |
Not provided
Not provided
Not provided
Not provided
Not provided
Masking of the participant:
The subject is randomized to one of three groups: 1: acupuncture, 2: TENS, and 3: sham-TENS. While those assigned to the acupuncture group are aware of their group assignment, groups 2 and 3 receive an identical TENS pad placement. A sham-TENS unit is used with disconnected wires to provide a blinking light without an electrical signal. Participants are advised that that the sensation of electrical tingling is not necessary.
Masking of the examiner:
The acupuncture or TENS/sham/TENS is performed by one examiner. A second examiner will enter the room to perform the gag reflex measurement, both before and after the treatment
| TENS |
| Device |
TENS of acupoints P-6 and St-36 |
|
| Sham-TENS | Device | Sham-TENS of acupoints P-6 and St-36 |
|
| D012046 | Rehabilitation |
| D000698 | Analgesia |
| D000760 | Anesthesia and Analgesia |