Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this clinical investigation is to assess the safety and performance of the SonoClear Acoustic Coupling Fluid (ACF). The performance will be assessed by analysis of the contrast-to-noise ratio (CNR) and assessment of image quality by using the Surgeon Image Rating (SIR) Scale.
This is a prospective, multi-centre single-arm study where the performance of SonoClear ACF relative to routinely used acoustic coupling fluid is investigated by each patient being their own control. Patients with the diagnosis of HGG and LGG at up to 10 sites will be included. Additionally, safety data are collected at 30 days and 6 months post-procedure.
Ultrasound images will be obtained at different timepoints during the operation. First timepoint being after craniotomy (no fluids involved). Second timepoint being when some tumour is left in the bottom of the deeper part of the resection cavity (approximately 80% of tumour removed), and third timepoint being when the surgeon deems resection of the tumour to be completed. At the second and third timepoint ultrasound acquisition will be performed twice at each timepoint. Once with routinely used saline / Ringer's solution and once with SonoClear ACF.
There are two performance related primary endpoints, based on core lab assessments:
This SIR is designed to explore whether SonoClear ACF, having shown to provide better quantitative image quality in the CNR analysis, allows surgeons to detect this improved image quality. Eventually this improved image quality should result in better decision-making during surgery about margins of excision and residual tumour resection.
Primary Safety Endpoint
The primary safety hypothesis is to prove the primary safety event rate is less than 10%. The primary safety event is defined as any core lab determined major MRI finding when post-operative MRI is compared to pre-operative MRI that was found by the DMC to be serious and probably or definitely related to the study device OR any DMC determined serious adverse event that is probably or definitely related to the study device that occurs within 30 days of the procedure. Success is demonstrated by observing 0 of these events out of 37 subjects exposed to SonoClear ACF. This is equivalent to a two-sided p-value less 0.05 for the alternative hypothesis that the primary safety event rate in subjects undergoing tumor resection using ACF is less than 10%.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SonoClear acoustic coupling fluid (ACF) mimicking brain tissue | Experimental | SonoClear |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| SonoClear ACF | Device | The SonoClear ACF is intended to be used as an acoustic coupling fluid during ultrasound imaging in brain surgery of human beings |
|
| Measure | Description | Time Frame |
|---|---|---|
| Contrast-to-Noise Ratio (CNR) to quantify the reduction in noise | To show that ultrasound images obtained when using SonoClear ACF are less influenced by image artefacts compared to images obtained when using routinely used saline solution measuring the contrast-to-noise ratio (CNR) in the images. | During ultrasound guided brain tumour resection |
| Surgeons Image Rating (SIR) to assess the image quality | Quality assessment of the images is done by the core-lab in a blinded manner using the Surgeon Image Rating (SIR) scale, a 1-10 rating scale to score the quality of the image according to 3 questions at different time points during the operation. First timepoint being after craniotomy (no fluids involved). The second time point is when some tumour is left in the bottom of the deeper part of the resection cavity (approximately 80% of tumour removed), and the third time point being when the surgeon deems resection of the tumour to be completed. | During ultrasound guided brain tumour resection |
| Adverse events up to 30 days post procedure | The primary safety hypothesis is to prove the primary safety event rate is less than 10%. A primary safety event is defined as any core lab determined major MRI finding when post-operative MRI is compared to pre-operative MRI that was found by the DMC to be serious and probably or definitely related to the study device OR any DMC determined serious adverse event that is probably or definitely related to the study device that occurs within 30 days of the procedure. Success is demonstrated by observing 0 of these events out of 37 subjects exposed to SonoClear ACF. This is equivalent to a two-sided p-value less 0.05 for the alternative hypothesis that the primary safety event rate in subjects undergoing tumor resection using ACF is less than 10%. | safety data are collected up to 30 days post procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universitätsklinikum Ulm | Günzburg | 89312 | Germany | |||
| Philipps-Universität Marburg |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001932 | Brain Neoplasms |
| D005910 | Glioma |
| D005909 | Glioblastoma |
| ID | Term |
|---|---|
| D016543 | Central Nervous System Neoplasms |
| D009423 | Nervous System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
Not provided
Not provided
A prospective, multi-centre single arm study
Not provided
Not provided
The following measures have been taken to minimize or avoid bias:
Due to the nature of brain surgery and the diversity of the tumours, it is seen as a strength to the trial that the patient can act as its own control even though the images can never be 100% the same in the separate image acquisition. This is especially true for 2D US images, whereas with a 3D US image it is more likely to obtain the same position for sequential image acquisition.
Not provided
| Marburg |
| 35037 |
| Germany |
| Instituto Neurologico "C. Besta" | Milan | 20133 | Italy |
| University Hospital Bratislava | Bratislava | 83305 | Slovakia |
| D001927 |
| Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D018302 | Neoplasms, Neuroepithelial |
| D017599 | Neuroectodermal Tumors |
| D009373 | Neoplasms, Germ Cell and Embryonal |
| D009370 | Neoplasms by Histologic Type |
| D009375 | Neoplasms, Glandular and Epithelial |
| D009380 | Neoplasms, Nerve Tissue |
| D001254 | Astrocytoma |