Evaluation of a novel mobile application designed to estimate blood pressure (systolic-diastolic and mean arterial pressure) based on collected optical signals on patient's finger treated in intensive care unit patients
The purpose of the study is to compare the blood pressure values measured by a novel mobile phone application ( camera of the smartphone will be obstructed by the patient's right index) and the values measured by reference method used (the radial arterial line)
All patients admitted in the intensive care unit at Erasme Hospital Brussels, Belgium will be recruited and if they have an arterial line for at least two days
The OptiBP Application is a mobile application installed on a mobile phone which is a non-invasive data-logger intended to acquire physiological data from patients. By applying the patient's finger on a smartphone's camera, a movie is generated and transformed into values of diastolic, mean and systolic blood pressure.
Three measures will be taken (spaced by one minute) with both methods each hour for 5 hours and this will be done for 2 days.
The patient's blood pressure will be measured in parallel with the mobile application and with the reference equipment (arterial line).
Then, the values obtained by the two methods will be compared to confirm the reliability of the data obtained with the novel mobile application.
The goal is therefore to compare blood pressure values as obtained by the analysis of the data recorded by the OptiBP Mobile Application, against simultaneous measurements provided by the arterial line (gold standard)
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| OPti BP measurements | Device | measurement of blood pressure with the new smartphone App ( OPTIBP) |
| Measure | Description | Time Frame |
|---|---|---|
| Comparison of blood pressure between the new smartphone App and the radial arterial line | Comparative blood pressure measurement with the investigational device and the invasive reference method (arterial line). | 48 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Usability assessment | Identification of possible use error in the manipulation of the device and in the performance of the measure | at 48 hour |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
All intensive care unit patients with an arterial catheter for at least 48 hours
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Alexandre JOOSTEN, MD PhD | ERASME | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ERASME | Brussels | 1070 | Belgium |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35971072 | Derived | Desebbe O, Anas C, Alexander B, Kouz K, Knebel JF, Schoettker P, Creteur J, Vincent JL, Joosten A. Evaluation of a novel optical smartphone blood pressure application: a method comparison study against invasive arterial blood pressure monitoring in intensive care unit patients. BMC Anesthesiol. 2022 Aug 15;22(1):259. doi: 10.1186/s12871-022-01797-0. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D007022 | Hypotension |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided