Water exchange (WE) improves adenoma detection rate (ADR) but missed polyps occur due to human limitations. Computer-aided detection (CADe) improves polyp detection and can overcome human omissions, but a limiting factor is feces and air bubbles related false alarms (FA). WE provides salvage cleansing and can potentially reduce FA. The investigators compared the additional polyp detection rate (APDR) and false alarm rate (FAR) by CADe between WE and air insufflation.
Worldwide colorectal cancer (CRC) is the second most common cancer in women and the third in men. Early detection and removal of the colon polyps (cancer precursors) reduce the incidence of CRC. However, interval colon cancers still occur within 3-5 years after colonoscopy among patients of colonoscopists with low adenoma detection rate (ADR), defined as the proportion of patients with at least one adenoma. ADR was widely variable, suggesting that some adenomas were missed. Twenty six percent of adenomas were missed during tandem examination reported in a recent meta-analysis. Missed adenomas accounted for about 58% of interval cancers. Adenomas are more likely to be missed in the right colon than in other segments because of their flat morphology and hiding behind the accentuated folds and curvatures. Innovations in colonoscopy to increase ADR and decrease adenoma miss rate (AMR) hold the potential to reduce interval cancers.
The consensus statements in a recent modified Delphi review confirmed water exchange (WE) as a standardized insertion method produced less insertion pain, better bowel cleanliness and higher ADR than gas insufflation. It is characterized by infusing water to guide insertion in an airless lumen and almost simultaneous suctioning of the infused water during insertion, aiming at near-complete removal of the infused water and debris upon cecal intubation. Although an RCT with tandem examination showed WE significantly decreased right colon adenoma miss rate (rAMR) compared with CO2 insufflation (18.0% [33/183] vs. 34.6% [62/179], P = 0.0025), a considerable percentage of polyps in the right colon were still overlooked.
In recent years, the field of machine learning and artificial intelligence has made remarkable progress, and an increasing number of publications showed improved polyp detection rate (PDR) and ADR using computer-aided detection (CADe). CADe can detect polyps overlooked by the colonoscopist due to human limitations of inattention or inexperience. However, one major drawback of current CADe systems is false alarms (FAs), or false positives (FPs). Usually triggered by bubbles and fecal debris, FAs might distract the endoscopists with potential unfavorable effect on ADR. One study reported a FP rate of up to 60%.
In an overview on applying deep learning algorithms and WE in colonoscopy to improve adenoma detection, the authors noted that WE could enhance the performance of artificial intelligence (CADe) by improving bowel cleanliness and thus the exposure of polyps. In a follow-up review, the authors reported that artificial intelligence might mitigate operator-dependent factors that limited the potential of WE, while WE might provide the platform to optimize the performance of artificial intelligence by increasing bowel cleanliness and improving visualization, Therefore, the strengths of WE and artificial intelligence may complement the weaknesses of each other to maximize adenoma detection.
One of our recently completed studies compared right colon ADR evaluated by a blinded endoscopist using either air insufflation or WE for insertion, with all the colonoscopies video recorded (NCT02737514). We developed and applied a CADe system to detect the polyps in the videos. The current report is a proof of principle study to test the hypothesis that WE could yield a significantly higher additional PDR (APDR) and reduce false alarms rate (FAR) as compared to air insufflation in the right colon.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Water exchange with computer-aided detection system | Computer-aided detection system overlaid videos with water exchange colonoscopy method |
| |
| Air insufflation with computer-aided detection system | Computer-aided detection system overlaid videos with air insufflation colonoscopy method |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Computer-aided detection system overlaid colonoscopy videos analysis | Other | Analysis of computer-aided detection system overlaid videos from colonoscopies performed with water exchange or air insufflation method. |
| Measure | Description | Time Frame |
|---|---|---|
| Polyp detection rate | To find out and compare the polyp detection rate on water exchange and air insufflation group | One month |
| Measure | Description | Time Frame |
|---|---|---|
| False positive rate of computer-aided detection system | To find out and compare the false positive rates on water exchange and air insufflation group | One month |
| False alarm rate of computer-aided detection system |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients were undergoing screen, diagnostic or surveillance colonoscopy were enrolled.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Chia Pei Tang | Dalin Tzu Chi General Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chia Pei Tang | Chiayi City | Chiayi | 62247 | Taiwan |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 33074950 | Background | Cheng CL, Kuo YL, Hsieh YH, Tang JH, Leung FW. Comparison of Right Colon Adenoma Miss Rates Between Water Exchange and Carbon Dioxide Insufflation: A Prospective Randomized Controlled Trial. J Clin Gastroenterol. 2021 Nov-Dec 01;55(10):869-875. doi: 10.1097/MCG.0000000000001454. | |
| 27988288 | Background | Hsieh YH, Tseng CW, Hu CT, Koo M, Leung FW. Prospective multicenter randomized controlled trial comparing adenoma detection rate in colonoscopy using water exchange, water immersion, and air insufflation. Gastrointest Endosc. 2017 Jul;86(1):192-201. doi: 10.1016/j.gie.2016.12.005. Epub 2016 Dec 15. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003111 | Colonic Polyps |
| ID | Term |
|---|---|
| D007417 | Intestinal Polyps |
| D011127 | Polyps |
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
To find out and compare the false alarm rates on water exchange and air
| One month |
| 33353642 | Background | Leung FW, Hsieh YH. Artificial intelligence (computer-assisted detection) is the most recent novel approach to increase adenoma detection. Gastrointest Endosc. 2021 Jan;93(1):86-88. doi: 10.1016/j.gie.2020.07.059. No abstract available. |
| 31981517 | Background | Wang P, Liu X, Berzin TM, Glissen Brown JR, Liu P, Zhou C, Lei L, Li L, Guo Z, Lei S, Xiong F, Wang H, Song Y, Pan Y, Zhou G. Effect of a deep-learning computer-aided detection system on adenoma detection during colonoscopy (CADe-DB trial): a double-blind randomised study. Lancet Gastroenterol Hepatol. 2020 Apr;5(4):343-351. doi: 10.1016/S2468-1253(19)30411-X. Epub 2020 Jan 22. |
| 32371116 | Background | Repici A, Badalamenti M, Maselli R, Correale L, Radaelli F, Rondonotti E, Ferrara E, Spadaccini M, Alkandari A, Fugazza A, Anderloni A, Galtieri PA, Pellegatta G, Carrara S, Di Leo M, Craviotto V, Lamonaca L, Lorenzetti R, Andrealli A, Antonelli G, Wallace M, Sharma P, Rosch T, Hassan C. Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial. Gastroenterology. 2020 Aug;159(2):512-520.e7. doi: 10.1053/j.gastro.2020.04.062. Epub 2020 May 1. |
| 32557490 | Background | Barua I, Vinsard DG, Jodal HC, Loberg M, Kalager M, Holme O, Misawa M, Bretthauer M, Mori Y. Artificial intelligence for polyp detection during colonoscopy: a systematic review and meta-analysis. Endoscopy. 2021 Mar;53(3):277-284. doi: 10.1055/a-1201-7165. Epub 2020 Sep 29. |
| 32598963 | Background | Hassan C, Spadaccini M, Iannone A, Maselli R, Jovani M, Chandrasekar VT, Antonelli G, Yu H, Areia M, Dinis-Ribeiro M, Bhandari P, Sharma P, Rex DK, Rosch T, Wallace M, Repici A. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc. 2021 Jan;93(1):77-85.e6. doi: 10.1016/j.gie.2020.06.059. Epub 2020 Jun 26. |
| 30814121 | Background | Wang P, Berzin TM, Glissen Brown JR, Bharadwaj S, Becq A, Xiao X, Liu P, Li L, Song Y, Zhang D, Li Y, Xu G, Tu M, Liu X. Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study. Gut. 2019 Oct;68(10):1813-1819. doi: 10.1136/gutjnl-2018-317500. Epub 2019 Feb 27. |
| 31755802 | Background | Hsieh YH, Leung FW. An overview of deep learning algorithms and water exchange in colonoscopy in improving adenoma detection. Expert Rev Gastroenterol Hepatol. 2019 Dec;13(12):1153-1160. doi: 10.1080/17474124.2019.1694903. Epub 2019 Nov 30. |
| 33069706 | Result | Cadoni S, Ishaq S, Hassan C, Falt P, Fuccio L, Siau K, Leung JW, Anderson J, Binmoeller KF, Radaelli F, Rutter MD, Sugimoto S, Muhammad H, Bhandari P, Draganov PV, de Groen P, Wang AY, Yen AW, Hamerski C, Thorlacius H, Neumann H, Ramirez F, Mulder CJJ, Albeniz E, Amato A, Arai M, Bak A, Barret M, Bayupurnama P, Cheung R, Ching HL, Cohen H, Dolwani S, Friedland S, Harada H, Hsieh YH, Hayee B, Kuwai T, Lorenzo-Zuniga V, Liggi M, Mizukami T, Mura D, Nylander D, Olafsson S, Paggi S, Pan Y, Parra-Blanco A, Ransford R, Rodriguez-Sanchez J, Senturk H, Suzuki N, Tseng CW, Uchima H, Uedo N, Leung FW. Water-assisted colonoscopy: an international modified Delphi review on definitions and practice recommendations. Gastrointest Endosc. 2021 Jun;93(6):1411-1420.e18. doi: 10.1016/j.gie.2020.10.011. Epub 2020 Oct 16. |