Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Astigmatism is a common refractive error resulting from a toric-surfaced cornea which using a toric soft contact lens could be one of the therapy options. Due to the numerous possible combinations between sphere powers, cylinder powers, and cylinder axes, manufacturers of disposable soft toric contact lenses limit their toric lens range, while still aiming to cater to the majority of astigmatic patients. Due to that reason, the possibility of astigmatism patients getting a different combination of power and axis with toric soft contact lenses sold on the market will be high due to SKU limitations. This research aims to ascertain the impact of altering cylinder power and axis on visual quality and convenience in astigmatism participants using toric soft contact lens. The study was conducted at Kirana Ciptomangunkusumo Hospital, Jakarta, starting in April 2020. The study is a prospective, randomized, participant-masked, crossover clinical trial where the participants were tested for the following conditions on different days using full spherocylinder correction and under-correction by 0.25, 0.50, and 0.75 DC while maintaining spherical equivalence. Axis was also misaligned between -30° and +30°, in 10° steps. For each visit, the patient was examined visual acuity, contrast visual acuity using the Pelli-Robson, and assessed patient comfort using the VAS method.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| soft contact lens Toric | Other | soft contact lens toric with different axis and power that use in human's eye |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Visual Acuity | Visual acuity was measured using a Snellen chart at a distance of 6 meters by the researcher (DA) at Refractive Poly | when using a contact lens (0 day,7 days, 14 days) |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Contrast sensitivity | Value obtained on examination of the Pelli Robson Chart in Poly Neurooftlamology. Examination conducted by researchers (DA). | when using a contact lens (0 day,7 days, 14 days) |
| Visual Clarity |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universitas Indonesia | Jakarta Pusat | Jakarta Special Capital Region | 10430 | Indonesia |
Not provided
Not provided
Not provided
Not provided
Not provided
Values were obtained by the VAS method. Research subjects were asked to name a number from 1-10 (score 1 indicates poor clarity, 10 indicates good clarity) to assess visual clarity
| when using a contact lens (0 day,7 days, 14 days) |
| Visual Satisfaction | Values were obtained by the VAS method. The research subjects were asked to name a number from 1-10 (a score of 1 indicates dissatisfaction, 10 indicates very satisfied) | when using a contact lens (0 day,7 days, 14 days) |