Modes of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and specifically the proportion of airborne transmission in this infection is unknown. In the aeroCOVID study, a highly efficient bioaerosol and droplet sampling dummy is used to emulate a susceptible healthcare worker (HCW) and to perform patient proximity sampling. The dummy will measure the dummy-inhaled dose of SARS-CoV-2 in two particle size fractions in a standardized interaction with hospitalized coronavirus disease 2019 (COVID-19) patients. All measurements are performed in a masked and unmasked dummy setup in parallel, in order to gain further information on the protection of type II masks against the respective particle size exposure.
Modes of interpersonal transmission in SARS-CoV-2 are to date only incompletely understood and require further investigation in order to define best preventive measures. Although a dichotomization of inhaled particles by particle size is an oversimplification and a large particle size does not exclude shortterm airborne behavior, the suspension time of virus containing particles and the probability of particles to accumulate in room air is primarily defined by particle size distribution. Particles with a size below 10 µm have a high probability of accumulation due to their mean suspension time of minutes to hours.
The study aims to measure the total amount of virus copies per particle size fraction inhaled by a highly efficient sampling dummy emulating a susceptible HCW in a standardized interaction with hospitalized COVID-19 patients. As a secondary endpoint, the proportion of culturable virus in each setup is measured as well.
Sampling is done in using two parallel bioaerosol and droplet sampling dummies - one type II masked and one with an unmasked dummy head as inlet - in order to gain additional information on the protective effect of type II surgical masks in a real-life exhaled particle size distribution in hospitalized COVID patients. The sampling dummy consists of a real size face relief connected to an 60° inlet cone, a cyclone for collection of particles >10 µm and a laminar flow water-based condensation bioaerosol collector for particle collection below 10 µm particle size.
After patient proximity sampling, a nasopharyngeal swab for SARS-CoV-2 polymerase chain reaction (PCR) assay is performed. Relevant indoor climate parameters like temperature, humidity and carbon dioxide (CO2) as well as room characteristics as air change rate are recorded as well.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Total amount of dummy-inhaled virus copies per 30 minutes sampling per size fraction (>10 µm, <10 µm) | 30 minutes sampling |
| Measure | Description | Time Frame |
|---|---|---|
| Viability of dummy-inhaled viable virus per size fraction (>10 µm, and <10 µm) | 30 minutes sampling | |
| Reduction of dummy-inhaled virus copies per 30 minutes sampling in a type II-masked setup, as compared to unmasked, per size fraction (>10 µm, <10 µm) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
The study is performed with hospitalized COVID-19 patients at Inselspital, Bern University hospital. The study site hospital is a tertiary university hospital treating COVID-19 patients on normal hospital wards as well as in the intensive care unit.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Philipp Jent, MD | University of Bern | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospital Bern | Bern | Switzerland |
Not provided
Not provided
Not provided
Not provided
Nasopharyngeal swab
| 30 minutes sampling |