The aim of this study is to explore the acceptability and feasibility of a novel medical device system for remote monitoring of breath and heart sounds (replicating remotely, and in an easy-to-use garment, that which a clinician would do with their stethoscope to listen to a patient's chest, by evaluating sounds captured through a wearable device (Senti)). As a first-in-man study, the investigators will investigate the safety of the Senti device, the usability and acceptability of the device; and ensure technical and practical feasibility of the device in a real-world clinical setting.
10 patients will be recruited (the study participants) in two tranches (6 and 4) who are being discharged from A&E into the care of the community respiratory team. These patients will wear the Senti device. The first tranche will use the device over a single session lasting 20 minutes only. The second tranche (which will include patients from tranche one, and which will only proceed if no adverse events are detected in tranche one), participants will wear the device at their discretion (particularly encouraged to wear overnight) over the course of 5 days. The investigators will survey the study participants to answer three key questions:
What is the feasibility of the Senti data-capture device?
Is this device usable in clinical practice?
What are the requirements to train patients to use the device?
The investigators will also consider:
Does the device function technically and practically, in real-world clinical scenarios?
What are the key expected and unexpected safety issues related to using the device (with a particular emphasis on whether the device is likely to cause pressure sores).
These questions will establish the feasibility of using the Senti data capture device as part of a novel medical device system for the autonomous evaluation and monitoring of bioacoustic signals.
TITLE: Remote Evaluation and Monitoring of Acoustic Pathophysiological parameters with external sensor technology.
DESIGN: First-In-Man and Feasibility study of the Senti Version 1 Device.
AIMS: To explore the acceptability and feasibility of a novel medical device for the remote monitoring and evaluation of acoustic pathophysiological parameters. - To investigate usability and acceptability of the Senti data capture device, and to ensure technical and practical functionality of the device in a real-world clinical scenario.
PRIMARY OUTCOMES: Device feasibility SECONDARY OUTCOMES: Length of time with the device in situ. The ease with which patients can apply the device.
POPULATION ELIGIBILITY: Patients being discharged home with community respiratory team support, after attending A&E.
DURATION: 3 Months. (Recruitment period: 2 months. Analysis and reporting: 1 month).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Senti Arm | Experimental | In stage 1 of this study (6 patients), the patient will apply the device and complete the initial patient survey; questions are around usability, comfort (including feelings of pressure), and acceptability. The Investigator will record the time taken to apply the device. A brief 30 seconds of chest sounds will be recorded from each of the nine sensors on the device in three different settings: standing up, lying down, walking around. In stage 2 of this study (10 patients; 6 of whom would be re-recruited from the first stage), the participant will use the device at home over five days. The Investigator will assess the participant daily for any signs of pressure sores or complications from using the device (including topical allergic reactions). The participant will complete a daily survey. The participant is encouraged to remove the device and apply it at their discretion. The participant can opt-out of wearing the device at any stage. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Senti V1.0 Device | Device | This device class I, CE marked garment, with a similar form to a T-Shirt, embedded with ten sensor modules encased in silicone; the device comes with a charging stand in the form of a clothes hanger. Depending on the outcome of this feasibility study, the device may, in the future, form part of a class IIb medical device system, when accompanied by cloud-based software to listen to both current and historically recorded breath sounds for each Senti patient. The Senti Version One device will be labelled clearly to indicate the device version, on the inside of the garment, conforming to the MDR. The garment itself will be made from textile composite, including cotton, elastase, micromodel, spandex, and polyester. All other components (including electronic and other plastic components) will be entirely encased in medical-grade silicone. |
| Measure | Description | Time Frame |
|---|---|---|
| Patient-rated device acceptability | Patient questionnaire "on a scale of 1 ("I would not approve at all") to 5 ("I would greatly approve and would like this to become standard practice"), to what extent would you approve of this device being used to enable clinicians to assess your heart and lung sounds as part of a telephone consultation?" | 1 month |
| Patient-rated device comfort | Patient questionnaire "on a scale of 1 ("Very difficult to use") to 5 ("Very easy to use"), how easy to use is the device?" | 1 month |
| Patient-rated device ease of use | Patient questionnaire "on a scale of 1 ("Too uncomfortable to use for more than an hours or so") to 5 ("As comfortable as a T-Shirt"), how comfortable is the device?" | 1 month |
| Expert-rated device data quality | An appropriately qualified person (with clinical experience of auscultation) to rate quality of data captured by the device, as compared subjectively against the quality that they typically expect from standard auscultation, on a scale of 1 ("Much poorer data quality [than standard auscultation]") to 3 ("equivocal data quality") to 5 ("Much higher data quality"). | 1 month |
| Adverse events and adverse device events. | The number of participants experiencing adverse events, both arising from use of the device or otherwise, will be reported. Adverse events will be categorised as unexpected or expected, serious or otherwise, device-related or un-related. | 1 month |
| Measure | Description | Time Frame |
|---|---|---|
| Length of time spent with the device on the patient. | Length of time over which a patient has used the device, as measured using a structured, binned multiple-choice survey. This is a custom-made scale titled "In the past 24 hours, for how many hours have you worn the Senti device?" with a minimum value of 0 hours and a maximum value of 24 hours. 8 options which include a range of times are available for selection. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Philip Alton, Mb ChB | Contact | +447724129546 | phil.alton@senti.care |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Senti Tech | Liverpool | Merseyside | L1 0AX | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| ID | Term |
|---|---|
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
A pilot stage, exploratory, First-In-Human and traditional feasibility, interventional study of the Senti V1.0 device (CE marked, Class I device), involving 10 patients attending A&E, who are being discharged into the care of the community respiratory team. 5 devices will be used, to cover a range of sizes from extra-small to extra-large.
Not provided
Not provided
Not provided
Not provided
|
| 1 month |
| Length of time taken for the patient to apply the device | Length of time taken for the patient to put the device on, as measured by an investigator with a stop watch. | 1 month |
| Time spent to train patients to use the device. | Length of time taken to train patients to use the device, as measured by an investigator with a stop watch. | 1 month |
| Pressure sore EPUAP grade | For those patients who develop pressure sores, the pressure sore will be graded using the European Pressure Ulcer Advisory Panel grading system from a grade of grade 1 through to grade 4, including unclassified gradings and moisture lesions. (Patients will be graded as "No pressure sores" if there are no pressure sores noted on examination). | Through study completion, once per day. |