The main purpose of this study is to compare the effectiveness of various non-invasive elastography techniques at determining liver stiffness measures in human subjects. Specifically, the investigators are comparing MRE and FibroScan to Vibroelastography (VE, Liver Incytes System). These techniques are used to measure stiffness in the liver.
The Liver Incytes system allows for full visualization of the liver with the low cost and portability of ultrasound. It is an adjustable multi-frequency technique, which can show large areas of the organ as volumetric elasticity maps. The device uses the Shear Wave Absolute Vibro-Elastography (S-WAVE) method.
The primary objective of the study is to determine the relationship between the elasticity results from Liver Incytes and those of MR Elastography. In addition to stiffness measurements, the relationship between the Liver Incytes attenuation measurements and MR-PDFF will also be evaluated.
As secondary objectives, the ability of Liver Incytes to correctly stage patients using MRE as the standard (unless biopsy is available), looking specifically at the ability to measure mild and advanced fibrosis.
In additional to performance objectives, the safety, tolerability and usability of the device will be assessed.
This is a prospective, open label, validation study of the Liver Incytes system in comparison to MR results (as gold standard) in patients with liver disease or suspected liver disease. Approximately 100 subjects may be enrolled in this study which will take place at clinical centers across Canada and the United States. Study participants should be distributed primarily across the 4 stages of fibrosis, with secondary consideration of the three stages of steatosis.
The study is comprised of: Screening Period (up to 28 days) and Data Collection Period. There are no safety follow-up visits in this study.
The total duration of study participation will vary from approximately 2 weeks to approximately 8 weeks.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Open-label | Experimental | Volunteers who have agreed to participate in the study will have their liver scanned using the FibroScan, VE (Liver Incytes System) and MRE techniques. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Liver Incytes System | Device | The Liver Incytes System uses the Shear Wave Absolute Vibro-Elastrography (S-WAVE) method. The imaging procedure of the Liver Incytes system is similar to a traditional ultrasound scanning procedure or FibroScan, in which the patient is asked to lie supine on an examination bed, with the operator seated next to them. A vibration source is placed under the patient, between the patient and the bed to induce shear waves in the liver. Ultrasound imaging through the patient ribs is used to track the displacements of these waves. Through tracking of the displacements, the shear wave velocity and tissue stiffness can be calculated. The use of volumetric multi-frequency imaging increases the amount of liver scanned |
| Measure | Description | Time Frame |
|---|---|---|
| Elasticity measurements comparison between Liver Incytes MR Elastography | Elasticity measurements (kPa) from the Liver Incytes system and the MR system will be compared to determined whether the reported stiffness of the tissue (mean and 95% confidence intervals) are equivalent by concordance correlation coefficient and 95% confidence intervals. | 12 months |
| Determination of Liver Incytes' discriminatory ability of liver stiffness as measured by fibrosis staging | Liver Incytes liver stiffness values will be compared to values obtained using MRE to determine the cutoff values for the Liver Incytes System for each level of fibrosis staging. For each stage of fibrosis as defined by MRE, Area Under the Receiver Operating Curve (AUROC) for Liver Incytes elasticity will be calculated and the cutoff maximizing the sensitivity and specificity will be determined. | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Attenuation measurements comparison between the Liver incytes System and MRI Proton Density Fat Fraction | Attenuation measurements (dB/m) from the Liver Incytes System and MRI proton density fat fraction will be compared to determine whether they are equivalent by concordance correlation coefficient and 95% confidence intervals | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Identification of cases in which FibroScan may overestimate or underestimate liver stiffness | The elasticity (kPa) output from Liver Incytes, FibroScan, and MRE/PDFF will be used to identify and compare the cases in which the measurements do not match. Descriptive statistics regarding the populations in which the FibroScan systematically over or underestimates compared to MRE/MRI PDFF and the corresponding results from Liver Incytes |
Inclusion Criteria:
Previous liver biopsy consistent with NAFLD OR
Evidence of hepatic steatosis on non-invasive assessment by one or more of the following criteria:
Exclusion Criteria:
Active viral hepatitis
a. Patients with cured HCV (those with history of treatment and have Sustained Viral Response for 12 weeks (SVR12)) or controlled HBV with no viral detected for more than 6 months are eligible
Decompensated cirrhosis (history of ascites, encephalopathy, or variceal bleeding)
ALT or AST > 5 x ULN on historical blood work within the past 3 months
BMI greater than 40 kg/m2 (or using cutoff based on MRI)
Other known causes of chronic liver disease
Individuals with history of persistent ethanol abuse (alcohol consumption > 20g etoh/day for women, > 40 g etoh/day for men)
Individuals with surgically removed gallbladder
Pregnant or planning to become pregnant while enrolled in this study
Other conditions which would exclude patients from entering an MRI
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Beth Israel Deaconess Medical Centre | Boston | Massachusetts | 02215 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Comparison between Liver Incytes' and FibroScan's fibrosis staging capabilities |
Compare the discriminatory ability of Liver Incytes' and FibroScan's elasticity (kPa) measurements in determining different stages of fibrosis using MRE as gold standard. For each stage of fibrosis, a Receiver Operating Curve will be constructed using the corresponding FibroScan measurements, and the Area Under the Receiver Operating Curve (AUROC) will be compared to the result from Liver Incytes. |
| 12 months |
| Comparison between Liver Incytes' and FibroScan's steatosis staging capabilities | Compare the discriminatory ability of Liver Incytes' and FibroScan's attenuation measurements (dB/m) in determining different stages of steatosis using MRE as gold standard. For each stage of steatosis, a Receiver Operating Curve will be constructed using the corresponding FibroScan measurements, and the Area Under the Receiver Operating Curve (AUROC) will be compared to the result from Liver Incytes. | 12 months |
| Incidence of and Device Deficiencies | The frequency of device deficiencies and failures will be described based on events reported | 12 months |
| Incidence of Adverse Events | Descriptive statistics including frequency and severity of all reported adverse events. | 12 Months |
| 12 months |
| Identification of cases in which FibroScan may overestimate or underestimate fat content | The attenuation (dB/m) output from Liver Incytes, FibroScan, and MRE/PDFF will be used to identify and compare the cases in which the measurements do not match. Descriptive statistics regarding the populations in which the FibroScan systematically over or underestimates compared to MRE/MRI PDFF and the corresponding results from Liver Incytes | 12 months |
| Liver Incytes System User Experience Survey | Descriptive statistics such as N, proportion, mean, median, SD, and range will be calculated for the composite score of the User Experience Survey, based on the modified System Usability Scale (mSUS). Descriptive statistics such as N, proportion, mean, median, SD, and range will be calculated for each question in the User Experience Survey and Liver Incytes Session Questionnaire. The modified SUS yields a single number representing a composite measure of the overall usability of the system being studied. It is composed of 10 questions, 5 positive in nature, and 5 negative. The score ranges from 0 to 6 and higher scores may mean a better or worse outcome depending on whether the question is positive or negative. | 12 months |
| Liver Incytes System Inter-user Elasticity Variability | For subjects who participate in the optional additional visit, inter-user device variability, if applicable, will be assessed by comparing reported elasticity (kPa). Variance for each measurement will be calculated. | 12 months |
| Liver Incytes System Inter-user Attenuation Variability | For subjects who participate in the optional additional visit, inter-user device variability, if applicable, will be assessed by comparing reported attenuation (dB/m). Variance for each measurement will be calculated. | 12 months |
| Liver Incytes System Intra-Subject Variability | For subjects who participate in the optional additional visit, intra-subject variability will be assessed by comparing reported elasticity (kPa). Variance for each measurement will be calculated. | 12 months |
| ID | Term |
|---|---|
| D065626 | Non-alcoholic Fatty Liver Disease |
| D008103 | Liver Cirrhosis |
| D005234 | Fatty Liver |
| ID | Term |
|---|---|
| D008107 | Liver Diseases |
| D004066 | Digestive System Diseases |
| D005355 | Fibrosis |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided