Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Simulation of pursed-lips breathing by defined stenoses in pulmonary function diagnostics to quantify the effect of the pursed-lips breathing
Since many years it is recommended for COPD patients to reduce the crossdiameter of the lips in order to improve the exhalation by means of so-called pursed-lips breathing (PLB). But the effects have never been studied quantitatively. In this study, the PLB effect is simulated during lung function diagnostics, using different sized resistors inserted into the routine mouthpiece of the flow sensor to resemble the effective airway resistances of a PLB maneuver. This prospective, randomized study includes 20 healthy subjects and 50 COPD patients, who will perform lung function testing with 4 different sized resistors.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Healthy | Experimental | Lung-healthy subjects, randomized lung function testing |
|
| Patient 1 | Experimental | COPD patients, randomized lung function testing |
|
| Patient 2 | Experimental | COPD patients, randomized lung function testing |
|
| Patient 3 | Experimental | COPD patients, randomized lung function testing |
|
| Patient 4 | Experimental | COPD patients, randomized lung function testing |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Baseline | Other | Lung function testing with MasterScreen™ Body, CareFusion Germany GmbH |
|
| Measure | Description | Time Frame |
|---|---|---|
| Lung function parameter FEV1 | Measuring of lung function parameters with different resistors to simulate PLB unit: L, measured with der MasterScreen™ Body, CareFusion | up to 1 hour |
| Measure | Description | Time Frame |
|---|---|---|
| PEF - expiratory Peak Flow | unit: L, measured with der MasterScreen™ Body, CareFusion | up to 1 hour |
| RV%TLC | unit: %, measured with der MasterScreen™ Body, CareFusion |
Not provided
Inclusion Criteria:
Patients:
Healthy:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Märkische Kliniken GmbH, Klinikum Lüdenscheid | Lüdenscheid | North Rhine-Westphalia | 58515 | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D029424 | Pulmonary Disease, Chronic Obstructive |
| ID | Term |
|---|---|
| D008173 | Lung Diseases, Obstructive |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
| D002908 | Chronic Disease |
Not provided
Not provided
| ID | Term |
|---|---|
| C074807 | BaseLine dental cement |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| MESH-Resistor 5 | Other | Lung funtion testing with MasterScreen™ Body, CareFusion Germany GmbH, Mouthpiece with mesh-resistor (5hPa/L) to create laminar airflow |
|
|
| MESH-Resistor 10 | Other | Lung funtion testing with MasterScreen™ Body, CareFusion Germany GmbH, Mouthpiece with mesh-resistor (10hPa/L) to create laminar airflow |
|
|
| Perforated Resistor 7 | Other | Lung function testing with MasterScreen™ Body, CareFusion Germany GmbH, Mouthpiece with perforated resistor (inside diameter 7mm) to create a turbulent airflow |
|
|
| Perforated Resistor 11 | Other | Lung function testing with MasterScreen™ Body, CareFusion Germany GmbH, Mouthpiece with perforated resistor (inside diameter 11mm) to create a turbulent airflow |
|
|
| up to 1 hour |
| D020969 |
| Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |