This clinical study will involve performing a series of medical imaging procedures of the abdomen using both ultrasound and MRI modalities in subjects at risk for or already diagnosed with Nonalcoholic Fatty Liver Disease (NAFLD). The primary objective of this clinical study is to evaluate the clinical feasibility of an investigational ultrasound technique for quantifying liver fat by comparing specific ultrasound-derived biomarkers with the liver fat percentage obtained from MRI Proton Density Fat Fraction (MRI-PDFF) measurements. All subjects enrolled in this study will undergo two investigational abdominal ultrasound examinations using the Philips EPIQ Ultrasound System and one MRI PDFF examination according to the clinical standard of care.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Investigational Ultrasound Imaging for Liver Fat Quantification | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Investigational Liver Fat Quantification Software | Device | All subjects enrolled in this study will undergo two abdominal ultrasound examinations using the investigational Liver Fat Quantification feature on the Philips EPIQ Ultrasound System. In addition, all subjects will also undergo one MRI-PDFF examination according to the clinical standard of care. |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements Hepatorenal Index (HRI) of Ultrasound Biomarkers for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. The difference between the two operators was calculated at the subject level by averaging multiple measurements. To assess the correlation between measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. A higher HRI value indicates greater liver fat accumulation, which reflects a worse outcome, while a lower HRI suggests less hepatic fat and a better outcome. | Intra-procedural (1 day) |
| Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements of Acoustic Attenuation (dB/cm/MHZ) Ultrasound Biomarker for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. To assess the correlation between subject averaged measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. Correlation of each ultrasound biomarker with the liver fat percentage reported from MRI-PDFF is assessed independently to evaluate individual biomarker performance. A higher attenuation value indicates worse liver condition, while a lower attenuation value suggests better liver status. | Intra-procedural (1 day) |
| Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements of Tissue Stiffness (kPa) Ultrasound Biomarker for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. To assess the correlation between subject averaged measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. This measured the MRI PDFF fat fraction used as the standard to evaluate the Tissue stiffness (kPa) measurements. Correlation of each ultrasound biomarker with the liver fat percentage reported from MRI-PDFF is assessed independently to evaluate individual biomarker performance. |
| Measure | Description | Time Frame |
|---|---|---|
| To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker "Hepatorenal Index (HRI)" | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. A higher HRI value indicates greater liver fat accumulation, which reflects a worse outcome, while a lower HRI suggests less hepatic fat and a better outcome. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Anthony E. Samir, MD | Massachusetts General Hospital | Principal Investigator |
| Stephan Anderson, MD | Boston Medical Center | Principal Investigator |
| Richard G Barr, MD, PhD | Radiology Consultants, Inc | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Massachusetts General Hospital | Boston | Massachusetts | 02114 | United States | ||
| Boston Medical Center |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Investigational Ultrasound Imaging for Liver Fat Quantification | Investigational Liver Fat Quantification Software: All subjects enrolled in this study will undergo two abdominal ultrasound examinations using the investigational Liver Fat Quantification feature on the Philips EPIQ Ultrasound System. In addition, all subjects will also undergo one MRI-PDFF examination according to the clinical standard of care. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
60 participants used for Baseline Characteristics
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Investigational Ultrasound Imaging for Liver Fat Quantification | Investigational Liver Fat Quantification Software: All subjects enrolled in this study will undergo two abdominal ultrasound examinations using the investigational Liver Fat Quantification feature on the Philips EPIQ Ultrasound System. In addition, all subjects will also undergo one MRI-PDFF examination according to the clinical standard of care. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements Hepatorenal Index (HRI) of Ultrasound Biomarkers for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. The difference between the two operators was calculated at the subject level by averaging multiple measurements. To assess the correlation between measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. A higher HRI value indicates greater liver fat accumulation, which reflects a worse outcome, while a lower HRI suggests less hepatic fat and a better outcome. | Each enrolled subject underwent up to two ultrasound scans conducted by two different operators, resulting in a total of 119 non missing scans reviewed for this study. The primary outcome measure, the Hepatorenal Index, was calculated based on these scans. The hepatorenal index measurement from each ultrasound scan was reviewed. | Posted | Mean | Standard Deviation | Hepatorenal Index | Intra-procedural (1 day) | ultrasounds scans | ultrasounds scans |
|
8 weeks
There are no significant Anticipated Adverse Events and Anticipated Adverse Device Effects associated with this clinical study because the investigational procedure is limited to noninvasive diagnostic ultrasound imaging of the abdomen using the investigational LFQ software.
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Investigational Ultrasound Imaging for Liver Fat Quantification | Investigational Liver Fat Quantification Software: All subjects enrolled in this study will undergo two abdominal ultrasound examinations using the investigational Liver Fat Quantification feature on the Philips EPIQ Ultrasound System. In addition, all subjects will also undergo one MRI-PDFF examination according to the clinical standard of care. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Rob Johnson | Philips Ultrasound LLC. | 42527572756 | rob.johnson_1@philips.com |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | May 31, 2019 | Oct 8, 2024 | Prot_SAP_001.pdf |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D065626 | Non-alcoholic Fatty Liver Disease |
| D008107 | Liver Diseases |
| D004066 | Digestive System Diseases |
| ID | Term |
|---|---|
| D005234 | Fatty Liver |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Intra-procedural (1 day) |
| Intra-procedural (1 day) |
| To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker "Hepatorenal Index (HRI)" | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | Intra-procedural (1 day) |
| To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker Acoustic Attenuation (dB/cm/MHZ) | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | Intra-procedural (1 day) |
| To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker Tissue Stiffness (kPa) | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | Intra-procedural (1 day) |
| To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker Acoustic Attenuation (dB/cm/MHZ) | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. | Intra-procedural (1 day) |
| To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker Tissue Stiffness (kPa) | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. | Intra-procedural (1 day) |
| Boston |
| Massachusetts |
| 02118 |
| United States |
| Radiology Consultants, Inc | Boardman | Ohio | 44512 | United States |
| Participants |
|
| Age, Continuous | Mean | Standard Deviation | years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Title |
|---|
| Description |
|---|
| OG000 | Investigational Ultrasound Imaging for Liver Fat Quantification | Investigational Liver Fat Quantification Software: All subjects enrolled in this study will undergo two abdominal ultrasound examinations using the investigational Liver Fat Quantification feature on the Philips EPIQ Ultrasound System. In addition, all subjects will also undergo one MRI-PDFF examination according to the clinical standard of care. |
|
|
|
| Primary | Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements of Acoustic Attenuation (dB/cm/MHZ) Ultrasound Biomarker for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. To assess the correlation between subject averaged measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. Correlation of each ultrasound biomarker with the liver fat percentage reported from MRI-PDFF is assessed independently to evaluate individual biomarker performance. A higher attenuation value indicates worse liver condition, while a lower attenuation value suggests better liver status. | Each enrolled subject underwent up to two ultrasound scans conducted by two different operators, resulting in a total of 120 scans reviewed for this study. The primary outcome measure, the Acoustic Attenuation (dB/cm/MHZ), was evaluated based on these scans. | Posted | Mean | Standard Deviation | dB/cm/MHZ | Intra-procedural (1 day) | Ultrasound scans | Ultrasound scans |
|
|
|
|
| Primary | Correlation of the Liver Fat Percentage Reported From MRI-PDFF With Measurements of Tissue Stiffness (kPa) Ultrasound Biomarker for Liver Fat. | For each biomarker per subject, multiple quantitative measurements were acquired on the same day by two different operators. To assess the correlation between subject averaged measurements derived from the investigational LFQ feature and the 'clinical' MRI-PDFF fat fraction obtained from the subject's medical record. This measured the MRI PDFF fat fraction used as the standard to evaluate the Tissue stiffness (kPa) measurements. Correlation of each ultrasound biomarker with the liver fat percentage reported from MRI-PDFF is assessed independently to evaluate individual biomarker performance. | Each enrolled subject underwent up to two ultrasound scans conducted by two different operators, resulting in a total of 120 scans reviewed for this study. The primary outcome measure, the Tissue Stiffness, was evaluated based on these scans. | Posted | Mean | Standard Deviation | kPa | Intra-procedural (1 day) | Ultrasound scans | Ultrasound scans |
|
|
|
|
| Secondary | To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker "Hepatorenal Index (HRI)" | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. A higher HRI value indicates greater liver fat accumulation, which reflects a worse outcome, while a lower HRI suggests less hepatic fat and a better outcome. | The analysis included 119 ultrasound scans, performed by two different operators, from 60 enrolled participants. One participant scan was excluded due to missing Hepatorenal Index (HRI) data. The hepatorenal index measurement was calculated from each ultrasound scan and the difference between the two operators was reviewed. | Posted | Mean | Standard Deviation | Hepatorenal Index | Intra-procedural (1 day) | ultrasound scans | ultrasound scans |
|
|
|
|
| Secondary | To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker "Hepatorenal Index (HRI)" | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | To quantify the number of overall subjects with at least one unacceptable image quality | Posted | Count of Participants | Participants | Intra-procedural (1 day) |
|
|
|
|
| Secondary | To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker Acoustic Attenuation (dB/cm/MHZ) | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | 60 participants enrolled were included in the analysis. | Posted | Count of Participants | Participants | Intra-procedural (1 day) |
|
|
|
|
| Secondary | To Evaluate the LFQ Data Acquisition Failure Rate for Investigating Biomarker Tissue Stiffness (kPa) | To evaluate the LFQ data acquisition failure rate, the proportion of subjects who have at least one unacceptable image quality due to inadequate acoustic scanning windows, motion artifacts, or other technical limitations | 60 participants enrolled were included in the analysis. | Posted | Count of Participants | Participants | Intra-procedural (1 day) |
|
|
|
|
| Secondary | To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker Acoustic Attenuation (dB/cm/MHZ) | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. | The analysis included 120 ultrasound scans, performed by two different operators, from 60 enrolled participants. The Acoustic attenuation (dB/cm/MHZ) calculated from each ultrasound scan and the difference between the two operators was reviewed. | Posted | Mean | Standard Deviation | dB/cm/MHZ | Intra-procedural (1 day) | ultrasound scans | ultrasound scans |
|
|
|
|
| Secondary | To Evaluate the Same-day Inter-operator Variability for Investigating Biomarker Tissue Stiffness (kPa) | To assess the difference in quantitative ultrasound biomarker measurements which acquired from the same subject on the same day by two different operators who have undergone standardized training for LFQ data acquisition. The difference between the two operators was calculated at the subject level by averaging multiple measurements. | The analysis included 120 ultrasound scans, performed by two different operators, from 60 enrolled participants. The Tissue stiffness (kPa) was calculated from each ultrasound scan and the difference between the two operators was reviewed. | Posted | Mean | Standard Deviation | Tissue stiffness (kPa) | Intra-procedural (1 day) | ultrasound scans | ultrasound scans |
|
|
|
|
| 0 |
| 60 |
| 0 |
| 60 |
| 0 |
| 60 |
Not provided
Not provided
To assess the correlation between quantitative ultrasound biomarker "Acoustic attenuation " derived from the investigational LFQ feature and the clinical MRI-PDFF fat fraction obtained from the subject's medical record. |
| Pearson correlation coefficient |
| 0.7331 |
| 2-Sided |
| Other |
Pearson correlation coefficient was calculated based on the subject averages of multiple measurements. |
| To assess the correlation between quantitative ultrasound biomarker "Acoustic attenuation " derived from the investigational LFQ feature and the clinical MRI-PDFF fat fraction obtained from the subject's medical record. | Correlation estimated from a mixed model | 0.7066 | 2-Sided | Other | To account for within subject variance in repeated measures by two different operators, a method with MIXED model for repeated measurements was used to estimate the correlation between two techniques with repeated measures. An unstructured covariance matrix was used. |
To assess the correlation between quantitative ultrasound biomarker "Tissue stiffness" derived from the investigational LFQ feature and the clinical MRI-PDFF fat fraction obtained from the subject's medical record. |
| Pearson correlation coefficient |
| -0.0622 |
| 2-Sided |
| Other |
Pearson correlation coefficient was calculated based on the subject averages of multiple measurements. |
| To assess the correlation between quantitative ultrasound biomarker "Tissue stiffness" derived from the investigational LFQ feature and the clinical MRI-PDFF fat fraction obtained from the subject's medical record. | Correlation estimated from a mixed model | -0.0574 | 2-Sided | Other | To account for within subject variance in repeated measures by two different operators, a method with MIXED model for repeated measurements was used to estimate the correlation between two techniques with repeated measures. An unstructured covariance matrix was used. |