In this clinical trial, an un-controlled, repeated measures open design with within-subject comparison will be used to evaluate the effect of the device under investigation on sound perception. This design was shown to be successful in previous studies for the evaluation of sound coding strategies.
Furthermore, a within-subject comparison decreases the variance in the results allowing for fewer subjects when the population using the investigational device is not large in general.
The primary endpoint of this clinical investigation is the difference in speech intelligibility measured in percent correct with AutoZoomControl compared to an omnidirectional microphone on Naída M hearing devices.The Naída CI M90 sound processor is a behind-the-ear (BTE) sound processor based on the Phonak Marvel hearing aid platform. It replaces the market approved Naída CI Q-Series processors. The Naída Link M90 hearing aid is a behind-the-ear (BTE) hearing aid based on the Phonak Marvel hearing aid platform. It is especially designed to be used for bimodal CI users equipped with a Naída CI M90 sound processor.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Bilateral users: two implant systems | For bilateral CI users two Naida CI M sound processors (one per ear) will be used during the study. |
| |
| Bimodal users: hearing aid contralateral | For bimodal subjects there will be one Naida CI M sound processor on the implanted ear as well as one hearing aid on the contralateral ear. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Naida CI M hearing device | Device | speech intelligibility measurement with Naida CI M hearing device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Difference in speech intelligibility in noise | The primary endpoint of this clinical investigation is the difference in speech intelligibility measured in percent correct with AutoZoomControl compared to an omnidirectional microphone on Naída M hearing devices. The French Matrix Test will be used and percentage correct will be recorded. | 2 months |
| Measure | Description | Time Frame |
|---|---|---|
| Differences in speech perception in noise | ZoomControl versus Omnidirectional microphone and AutoZoomControl versus ZoomControlon Naída M hearing devices will be compared. The French Matrix Test will be used and percentage correct will be recorded. | 2 months |
| Differences in localization abilities |
Not provided
Inclusion Criteria:
· CI users with a CII, HiRes90K (Advantage) or HiRes Ultra (3D) implant system Bilateral users: two implant systems Bimodal users: hearing aid contralateral
Exclusion Criteria:
Difficulties additional to hearing impairment that would interfere with the study procedures
Not provided
Not provided
Not provided
The intended users of the Naída M hearing system are people who suffer from profound sensorineural hearing losses up to complete deafness. The users could be recipients that are already users of an Advanced Bionics CI but also people who suffer from deafness or profound hearing loss and were not previously equipped with a hearing device. In case of contralateral acoustic hearing, the user might use a Naída CI M90 on the side with profound sensorineural hearing loss and a Naída Link M90 as a hearing aid on the contralateral side to aid the residual acoustic hearing.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Angélica Pérez-Fornos, Dr | angelica.perez-fornos@hcuge.ch | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hôpitaux Universitaires de Genève (HUG) | Geneva | 1211 | Switzerland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006319 | Hearing Loss, Sensorineural |
| ID | Term |
|---|---|
| D034381 | Hearing Loss |
| D006311 | Hearing Disorders |
| D004427 | Ear Diseases |
| D010038 | Otorhinolaryngologic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
AutoZoom control versus Omnidirectional microphone, ZoomControl versus Omnidirectional microphone and AutoZoomControl versus ZoomControlon Naída M hearing devices will be compared. The directions (0,+/-90,180 degrees) from where the sentences of the French Matrix Test are presented have to be determined. Percentage correct will be recorded. |
| 2 months |
| D012678 |
| Sensation Disorders |
| D009461 | Neurologic Manifestations |
| D009422 | Nervous System Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |