Peripheral venous catheterisation is a multi-daily practice in a paediatric ward.
In our pediatrics department, nurses have observed for several years now the appearance of pressure sore-like skin lesions at the junction of the peripheral venous catheter with the extension tube. A ward habit has spontaneously developed of applying a compress under this junction. The objective is to minimize physical or emotional aggression as well as pain. Pain that is denied or not identified and not relieved is memorized by the child, which can have consequences on the perception of pain and the subsequent acceptance of care.
To date, through their reading and research, investigators have been able to find articles mentioning the risks of pressure ulcers in children related to medical devices. However, few elements are developed concerning catheter-related pressure ulcers, especially on this specific technique for preventing injuries at the catheter-extension tube junction. Investigators have not found any recommendations on this subject.
Thus, the aim of this study is to compare two peripheral venous catheter fixation devices, with compress and without compress, and to analyse the frequency of pressure ulcer occurrence and the intensity of this lesion.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| peripheral venous catheter with compress | Experimental | Insertion of a peripheral venous catheter with a compress inserted below the catheter-extension tube junction |
|
| peripheral venous catheter without compress | Active Comparator | Insertion of a peripheral venous catheter without any compress inserted below the catheter-extension tube junction. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| peripheral venous catheter with compress under the catheter-extension tube junction | Other | Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. Under the catheter-extension tube junction will be inserted a sterile non-woven compress, cut sterilely (3.5x1.5 cm). The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
| Measure | Description | Time Frame |
|---|---|---|
| Pressure Ulcer of Grade >=1 on the National Pressure Ulcer Advisory Panel (NPUAP) Scale | Occurrence of a pressure ulcer of grade ≥1 according to the NPUAP scale at the catheter extension junction. A higher grade on this scale indicates a worse patient outcome. The assessment will be performed in a blinded manner by a childcare assistant (CDA) from the department. | at catheter removal |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| stephanie Chaillot | CHD VENDEE | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHD Vendee | La Roche-sur-Yon | 85000 | France |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Peripheral Venous Catheter With Compress | Insertion of a peripheral venous catheter with a compress inserted below the catheter-extension tube junction peripheral venous catheter with compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. Under the catheter-extension tube junction will be inserted a sterile non-woven compress, cut sterilely (3.5x1.5 cm). The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Oct 3, 2023 |
Not provided
Not provided
Not provided
Not provided
The childcare assistant in charge of primary outcome assessment should not having taken care of the child before. In addition, the catheter-extension tube junction, with or without compress,will be secured by placing a crepe bandage. The nurse will call him to assess the primary outcome after the catheter ( and compress and crepe bandage) will have been removed.
|
| peripheral venous catheter without compress under the catheter-extension tube junction | Other | Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. No compresses will be inserted under the catheter-extension tube junction.The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
|
| FG001 | Peripheral Venous Catheter Without Compress | Insertion of a peripheral venous catheter without any compress inserted below the catheter-extension tube junction. peripheral venous catheter without compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. No compresses will be inserted under the catheter-extension tube junction.The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
| COMPLETED |
|
| NOT COMPLETED |
|
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Peripheral Venous Catheter With Compress | Insertion of a peripheral venous catheter with a compress inserted below the catheter-extension tube junction peripheral venous catheter with compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. Under the catheter-extension tube junction will be inserted a sterile non-woven compress, cut sterilely (3.5x1.5 cm). The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
| BG001 | Peripheral Venous Catheter Without Compress | Insertion of a peripheral venous catheter without any compress inserted below the catheter-extension tube junction. peripheral venous catheter without compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. No compresses will be inserted under the catheter-extension tube junction.The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). |
| BG002 | Total | Total of all reporting groups |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Median | Inter-Quartile Range | years |
| |||||||||||||||
| Sex: Female, Male | One observation as a missing data about gender | Count of Participants | Participants | No |
| ||||||||||||||
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
| |||||||||||||||
| Region of Enrollment | Number | participants |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Pressure Ulcer of Grade >=1 on the National Pressure Ulcer Advisory Panel (NPUAP) Scale | Occurrence of a pressure ulcer of grade ≥1 according to the NPUAP scale at the catheter extension junction. A higher grade on this scale indicates a worse patient outcome. The assessment will be performed in a blinded manner by a childcare assistant (CDA) from the department. | Posted | Count of Participants | Participants | at catheter removal |
|
|
|
Death, serious adverse events and other (non serious adverse events) were not assessed for the study
Death, serious adverse events and other (non serious adverse events) were not assessed for the study
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Peripheral Venous Catheter With Compress | Insertion of a peripheral venous catheter with a compress inserted below the catheter-extension tube junction peripheral venous catheter with compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. Under the catheter-extension tube junction will be inserted a sterile non-woven compress, cut sterilely (3.5x1.5 cm). The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). | 0 | 0 | 0 | 0 | 0 | 0 |
| EG001 | Peripheral Venous Catheter Without Compress | Insertion of a peripheral venous catheter without any compress inserted below the catheter-extension tube junction. peripheral venous catheter without compress under the catheter-extension tube junction: Placement of a BD Insyte® type catheter of 20 to 24 Gauge calibre on a peripheral vein located in the crease of the elbow or top of the hand or scalp or top of the foot. The catheter is placed while respecting the detersion and disinfection of the skin with the appropriate products and according to the procedure in force in the department. Once the venous return has been checked, a 10 cm extension with a BECTON-DIC® 3-way valve will be connected, which is previously purged with 0.9% Sodium Chloride. No compresses will be inserted under the catheter-extension tube junction.The assembly will be held in place by a transparent sterile semi-permeable adhesive dressing such as Tegaderm® (5x7 cm). This area will be secured by placing a crepe bandage (crepe bandage 4 m x7 cm). | 0 | 0 | 0 | 0 | 0 | 0 |
Not provided
Not provided
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Stéphanie BREHU | CHD Vendée | 06 88 39 85 17 | +33 | stephanie.brehu@ght85.fr |
| Dec 4, 2025 |
| Prot_SAP_000.pdf |
| ID | Term |
|---|---|
| D003668 | Pressure Ulcer |
| ID | Term |
|---|---|
| D012883 | Skin Ulcer |
| D012871 | Skin Diseases |
| D017437 | Skin and Connective Tissue Diseases |
Not provided