Sleep Apnea Syndrome (SAS) is a common pathology affecting between 4 and 8% of the general population. It aggravates morbidity and cardio-metabolic mortality and is responsible for accidents related to vigilance disorders. It is estimated that 80%% of SAS cases are not diagnosed and therefore not treated. It is however impracticable to propose a diagnostic test of polygraphy (PG) or polysomnography (PSG) to every patient because of the cost and insufficient availability of these exams. It would therefore be useful to carry out a screening test before directing the patient to a complete test.
Several simplified polygraph systems with 2 or 3 channels have been proposed (nasal cannula, oximetry, heart rate) but they generally record only one night and remain intrusive enough to perturb the sleep.
The Withings HWA09 is a wrist-worn watch, which allows screening of SAS from four signals: movement, heart rate, breathing rate and blood oxygen saturation (SpO2). The objective of the present study is to validate the diagnostic performance of the Withings HWA09 for the detection of SAS compared to PSG.
Subjects are patients having a prescription for a one-night polysomnographic consultation in order to diagnose potential sleep disorders. The investigator will collect the consent before including any patient in this study. The study last one night per patient, during which saturation signal recordings and the sleep apnea detection will be made by the HWA09 watch, in comparison to the polysomnography.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients referred for an overnight in-lab PSG | Simultaneous assessment of SAS with Withings HWA09 Device and overnight PSG |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| HWA09 Measurement | Diagnostic Test | Simultaneous recording of Withings HWA09 Device and PSG devices for the reference. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and Specificity of Withings HWA09 at AHI threshold value of 5/h in PSG | Sensitivity and specificity for SAS detection by Withings HWA09 compared to PSG at apnea-hypopnea index (AHI) threshold value of 5/h in PSG. | 1 year |
| Sensitivity and Specificity of Withings HWA09 at AHI threshold value of 15/h in PSG | Sensitivity and specificity for SAS detection by Withings HWA09 compared to PSG at AHI threshold value of 15/h in PSG. | 1 year |
| Sensitivity and Specificity of Withings HWA09 at AHI threshold value of 30/h in PSG | Sensitivity and specificity for SAS detection by Withings HWA09 compared to PSG at AHI threshold value of 30/h in PSG. | 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Sensitivity and Specificity of the desaturation detected by Withings HWA09 | Sensitivity and specificity of the desaturation detection by Withings HWA09 compared to an oximeter with the Oxygen Desaturation Index (ODI) | 1 year |
| Accuracy of Withings HWA09 to estimate total sleep time (TST) given by PSG |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients referred for an in-lab polysomnography
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gabriel Roisman | Antoine Béclère Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| St Pierre Hospital | Brussels | 1000 | Belgium | |||
| Antoine Béclère Hospital |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D012891 | Sleep Apnea Syndromes |
| ID | Term |
|---|---|
| D001049 | Apnea |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D020919 | Sleep Disorders, Intrinsic |
Not provided
Not provided
Not provided
Not provided
Not provided
Bias and mean absolute error (MAE) |
| 1 year |
| Impact of the proportion of apnea events on the performance of Withings HWA09 | Bias and MAE for apnea index (AI) estimated by Withings HWA09 compared to PSG results | 1 year |
| Impact of the proportion of hypopnea events on the performance of Withings HWA09 | Bias and MAE for hypopnea index (HI) estimated by Withings HWA09 compared to PSG results | 1 year |
| Influence of the position of the sleeper (supine vs prone/lateral decubitus position) on the error of the AHI predicted by Withings HWA09 compared with PSG | Average difference of AHI between Withings HWA09 and the PSG in each position | 1 year |
| Reliability of Withings HWA09 | Rate of unusable of lost nights | 1 year |
| Clamart |
| Île-de-France Region |
| 92140 |
| France |
| D020920 |
| Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |