the study aimed to evaluate the diagnostic performance of cardiac output (CO) change after the use of trinitrine in the diagnosis of heart failure patients with acute dyspnea.
Acute heart failure (AHF) is a frequent condition in emergency department and is responsible of high number of admissions, complications, and deaths.
despite advances in diagnostic techniques, AHF diagnosis still be challenging .
Measurement of cardiac output (CO) is used to evaluate global cardiac function and changes in CO may be used to identify a change in the hemodynamic status of patient.
the gold standard of measuring CO is thermodilution catheterization, however it is an invasive technique with high risks.
Impedance cardiography (ICG) is a noninvasive method for measuring CO. it is performed by applying small electrical current to the chest through electrodes placed on the neck and sides.
the pulsatile flow of blood causes fluctuations in the current, and the device calculates CO from the impedance waveform.
In practice, the investigators connect the device "BIOPAC" by using four electrodes which the investigators place on the base of the neck (posterior face) and on the base of the thorax (posterior face).
The ECG recording is taken simultaneously with two other electrodes placed at the right upper limb and left lower limb.
In addition to detecting the electric current and the ECG, heart sounds are recorded using a sensor that is placed at the mitral site.
Each patient is initially placed in a semi-sitting position at 30° for 5 minutes and then CO is measured (baseline CO). NTG (0.6 mg) is then given to the patient sublingually and CO measurement was repeated. CO is calculated by averaging three measurements at one minute intervals at baseline and after NTG administration. DeltaCO was defined as the percent of change of baseline CO after NTG test.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| reference group | Experimental | patients presenting to the emergency department with acute onset dyspnea are assessed for acute heart failure using the bio impedance technology (BIOPAC system) to measure the cardiac output in different clinical situations. FIRST: the cardiac output (CO) is measured at the reference position. Inbetween each step the patient was put in the reference position during 5 minutes. |
|
| TRINITRINE | Experimental | 0.6 mg of nitroglycerin was given to the patient sublingual and we measure the cardiac output by BIOPAC system(0.6 mg of Nitroglycerin was administered sublingually and CO was evaluated. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Reference position patient is put in a 30 degree supine position during 5 minutes | Diagnostic Test | Each patient is initially placed in a semi-sitting position at 30° for 5 minutes and then CO is measured (baseline CO) |
| Measure | Description | Time Frame |
|---|---|---|
| Cardiac output variation measured by ICG before and after nitroglycerin in acute dyspneic patients between the AHF and non AHF groups | the diagnostic performance is evaluated by calculating the CO in ml/min by bio-impedance technique and compare the values between patients with and without AHF and between baseline. | 24 hours |
| roc curve | Receiver operating characteristic (ROC) curves for predicting HF were constructed and area under curve (AUC) was measured for the deltaCO. | 24 |
| Sensitivity, specificity, positive and negative predictive values, and likelihood ratios of positive and negative results were calculated using the optimal cutoff value of deltaCO. | Sensitivity, specificity, positive and negative predictive values, and likelihood ratios of positive and negative results were calculated using the optimal cutoff value of deltaCO. | 24 hours |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| nouira semir, MD | University of Monastir | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Emergency department of fattouma bourguiba university hospital | Monastir | 5020 | Tunisia |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| D004417 | Dyspnea |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| nitroglucerin | Diagnostic Test | 0.6 mg of Nitroglycerin was administered by sublingual root and CO was evaluated. |
|
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |