Fractures of the proximal interphalangeal joints continue to pose significant management challenges. Thus the aim of our study is to compare two dynamic finger joint distractors (Litos® and Ligamentotaxor®) in respect to the radiological standard follow-up examination and functional assessments.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| LITOS | Patients who received a LITOS dynamic distraction system after 31.12.2017 |
| |
| Ligamentotaxor | Patients who received a Ligamentotaxor dynamic distraction system after 31.12.2017 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| LITOS | Device | Patients who received a LITOS dynamic distraction system after 31.12.2017 |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Disabilities of Arm, Shoulder and Hand (DASH) score | Disabilities as measured by the DASH scale; No Difficulty (1), Mild Difficulty (2), Moderate Difficulty (3), Severe Difficulty (4), Unable (5) | 3 months after explantation |
| Measure | Description | Time Frame |
|---|---|---|
| Visual analogue scale (VAS) pain | From 0mm (no pain) to 100mm (maximum pain imaginable) | 3 months after explantation |
| Functional assessment: Goniometry | ROM of each joint of the injured fingert with a goniometer. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
- additional fractures or disabilities of the hand
Not provided
Not provided
People who have sustained a proximal interphalangeal fracture treated with external dynamic fixator
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Markus Bock, MD | Contact | 00493081810201 | m.bock@waldfriede.de | |
| Matthias Url, MD | Contact | 00493081810201 | m.url@waldfriede.de |
| Name | Affiliation | Role |
|---|---|---|
| Markus Bock, MD | Waldfriede Hospital | Principal Investigator |
| Martin Lautenbach, MD | Waldfriede Hospital | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Waldfriede Hospital | Recruiting | Berlin | 14163 | Germany |
Not provided
Not provided
Not provided
Not provided
| Ligamentotaxor |
| Device |
Patients who received a Ligamentotaxor dynamic distraction system after 31.12.2017 |
|
| 3 months after explantation |