The objective of this study is to analyse the positioning of the scapula in standing position and compared to the supine position (CT scan) in 3 dimensions (3 rotations of the scapula) using a non-radiant, portable system, combining an ultrasound probe with marker and a camera integrated into a Tablet for the three-dimensional location of the marker (probe).
This is a mono-center trial. Patients in the process of pre-operative care of a reverse shoulder arthroplasty (CT Scan already available as part of the care course in supine position) will be offered the study. A localizer ultrasound will be performed during surgical consultation or the day before the surgery in standing position (duration: 1/2 day). This consultation takes place during the course of the surgical consultation or when the patient is admitted the day before his surgical procedure.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| shoulder localizer ultrasound | Experimental | The localizer ultrasound of the shoulder is performed on an unclothed patient (at the shoulders) and comes to locate bony landmarks using the ultrasound probe as a Transcutaneous localizer. The Protocol plans to acquire different landmarks on the scapula: lower angle, coracoid, scapula spine and bilateral acromioclavicular joint (definition of the coronal plan). These acquisitions are carried out by the probe connected to a Tablet (Microsoft surface Pro 3) which allows to locate the probe and by extension of the probe the location of the points selected by ultrasound. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Scapular positioning in Standing position using Sonography | Diagnostic Test | The localizer ultrasound of the shoulder is performed in an unclothed patient (at the shoulders) and comes to locate bony landmarks using the ultrasound probe as a Transcutaneous localizer. |
| Measure | Description | Time Frame |
|---|---|---|
| Study the location of the scapula in 3 dimensions for the patient in standing position | descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference coronal plane expressed in degree. Comparison with the supine position and analysis of any differences. | Day 1 |
| Study the location of the scapula in 3 dimensions for the patient in standing position | descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference axial plane expressed in degree. Comparison with the supine position and analysis of any differences. | Day1 |
| Study the location of the scapula in 3 dimensions for the patient in standing position | descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference sagittal plane expressed in degree. Comparison with the supine position and analysis of any differences. | Day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| Evaluating the accuracy of the device using a validation bench | Validation of the device using a biomechanical bench. The rotation will be assessed in coronal plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device | Day 1 |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Hoel LETISSIER, Dr | Contact | 689313164 | +33 | hoel.letissier@chu-brest.fr |
| Name | Affiliation | Role |
|---|---|---|
| Hoel LETISSIER, Dr | University Hospital, Brest | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Brest, University Hospital | Recruiting | Brest | 29609 | France |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This is mono-center study. Patients in the process of preoperative care of a Reverse Shoulder Arthroplasty (CT Scan already available as part of the extended care course) will be offered the study. A localizer ultrasound will be performed during surgical consultation or the day before the surgical procedure in standing position (duration: 1/2 day).
Not provided
Not provided
Not provided
Not provided
| Evaluating the accuracy of the device using a validation bench | Validation of the device using a biomechanical bench. The rotation will be assessed in axial plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device | Day 1 |
| Evaluating the accuracy of the device using a validation bench | Validation of the device using a biomechanical bench. The rotation will be assessed in sagittal plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device | Day 1 |