Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
An observational clinical trial in a single centre. The objective of this study was to determine the efficacy of mandibular advancement device (MAD) therapy on snoring intensity, frequency, and oxygen desaturation periods in mild-moderate obstructive sleep apnea (OSA) patients with snoring problems. Totally, 18 mild-moderate OSA patients (8 females and 10 males) with subjective snoring complaint were selected. Each patient's diagnostic polysomnographic analysis (PSG) was accepted as initial PSG values. Each patient was subjected simple pulse oximeter (SPO) and smartphone sleep application (SSA) at 3 different nights at home. Diagnostic mean values of oxygen desaturation index (obtained by using SPO), snoring intensity score (obtained by using SSA), and snoring percentage (obtained by using SSA) were recorded. Non-titratable-customized MAD with 60-75% of maximal mandibular protrusion were fabricated. The patients were instructed to wear their MAD every night. SPO and SSA measurement were repeated at the 1st, 4th, 12th, and 24th week of the treatment process. At the 24th week of treatment, The PSG were repeated and all PSG, SPO, and SSA values were compared with initial diagnostic values.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Mild-moderate OSA patients for MAD treatment | Patients are classified as mild Obstructive Sleep Apnea (OSA) if they have between 5-15 Apnea-Hypopnea Index, moderate if they have between 15-30, and severe if they have >30, as measured by Polysomnography (Epstein LJ, Kristo D, Strollo PJ, et al. 2009). The principal treatment methodology for OSA patients is positive airway pressure. In patients with mild to moderate OSA, oral appliances such as mandibular advancement devices (MAD) is alternately indicated (Ramar K, Dort LC, Katz SG, et al. 2015) The American Academy of Dental Sleep Medicine (Ramar K, Dort LC, Katz SG, et al. 2015) recommended titratable-customized MADs for patient comfort and the ability to permit modifications in the amount of mandibular protrusion for treatment efficacy. However, Aarab et al (Aarab G, Lobbezoo F, Hamburger HL, Naeije M. 2010) demonstrated similar therapeutic efficiency of non-titratable-customized MADs in the treatment of OSA |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Non-titratable-customized mandibular advancement device | Device | The most comfortable protruded mandibular position situated between 60-75% of MMPV was determined according to patient response with 6mm of the vertical interocclusal dimension between maxillary and mandibular central incisors and registered. The upper and lower acrylic resin splints were secured to each other in the posterior region with auto polymerizing acrylic resin and NTC-MADs were obtained. The patients were instructed to wear their non-titratable-customized mandibular advancement device every night. |
| Measure | Description | Time Frame |
|---|---|---|
| Change from Baseline Apnea-Hypopnea Index (AHI) at 6 months | AHI was defined as total number of apnea or hypopnea events which lasts for at least ten seconds per hour during full nigth polysomnography (PSG) and accepted to be the main physiological sleep parameter in the present study. The AHI values were used for the evaluation of the severity of OSA and the MAD's treatment success in OSA patients | at baseline and in 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Oxygen-desaturation index (ODI) | ODI was used to evaluate the desaturation fluctuations during full night PSG. ODI is defined as 3-4% decrease in oxygen saturation per hour. | at baseline and in 6 months |
| Snoring index (SI) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Mild-moderate obstructive sleep apnea patients were referred Department of Prosthodontics, Gülhane Faculty of Dentistry for oral appliance treatment
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Bulent Piskin, Prof. | Technology of Dental Prosthodontics, Kapadokya University, Turkey | Study Chair |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26094920 | Result | Ramar K, Dort LC, Katz SG, Lettieri CJ, Harrod CG, Thomas SM, Chervin RD. Clinical Practice Guideline for the Treatment of Obstructive Sleep Apnea and Snoring with Oral Appliance Therapy: An Update for 2015. J Clin Sleep Med. 2015 Jul 15;11(7):773-827. doi: 10.5664/jcsm.4858. | |
| 19536571 | Result | Aarab G, Lobbezoo F, Hamburger HL, Naeije M. Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea. Clin Oral Investig. 2010 Jun;14(3):339-45. doi: 10.1007/s00784-009-0298-9. Epub 2009 Jun 18. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020181 | Sleep Apnea, Obstructive |
| D012913 | Snoring |
| ID | Term |
|---|---|
| D012891 | Sleep Apnea Syndromes |
| D001049 | Apnea |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
SI was used to evaluate snoring events per hour during PSG
| at baseline and in 6 months |
| Simple pulse oximeter (SPO)/ODI | SPO/ODI was used to evaluate the desaturation fluctuations during sleep in-home environment by using simple pulse oximeter device | at baseline and 1, 4, 12, and 24 week of MAD treatment |
| Smartphone sleep application (SSA)/snoring intensity score (SIS) | SSA/SIS was used to evaluate snoring intensity that was calculated by SSA during sleep in-home environment. No information exists about how to calibrate the SSA to calculate SIS | at baseline and 1, 4, 12, and 24 week of MAD treatment |
| SSA/snoring percentage (SP) | SSA/SP was the ratio of total snoring time to total sleep time that was calculated by SSA during sleep in-home environment. No information exists about how to calibrate the SSA to calculate SP. | at baseline and 1, 4, 12, and 24 week of MAD treatment |
| 23016888 | Result | Zhou J, Liu YH. A randomised titrated crossover study comparing two oral appliances in the treatment for mild to moderate obstructive sleep apnoea/hypopnoea syndrome. J Oral Rehabil. 2012 Dec;39(12):914-22. doi: 10.1111/joor.12006. Epub 2012 Sep 27. |
| 20222022 | Result | Fiz JA, Jane R, Sola-Soler J, Abad J, Garcia MA, Morera J. Continuous analysis and monitoring of snores and their relationship to the apnea-hypopnea index. Laryngoscope. 2010 Apr;120(4):854-62. doi: 10.1002/lary.20815. |
| 28422345 | Result | Umemoto G, Toyoshima H, Yamaguchi Y, Aoyagi N, Yoshimura C, Funakoshi K. Therapeutic Efficacy of Twin-Block and Fixed Oral Appliances in Patients with Obstructive Sleep Apnea Syndrome. J Prosthodont. 2019 Feb;28(2):e830-e836. doi: 10.1111/jopr.12619. Epub 2017 Apr 19. |
| 27380034 | Result | Isacsson G, Fodor C, Sturebrand M. Obstructive sleep apnea treated with custom-made bibloc and monobloc oral appliances: a retrospective comparative study. Sleep Breath. 2017 Mar;21(1):93-100. doi: 10.1007/s11325-016-1377-1. Epub 2016 Jul 5. |
| 17251319 | Result | Jobin V, Mayer P, Bellemare F. Predictive value of automated oxygen saturation analysis for the diagnosis and treatment of obstructive sleep apnoea in a home-based setting. Thorax. 2007 May;62(5):422-7. doi: 10.1136/thx.2006.061234. Epub 2007 Jan 24. |
| 27026417 | Result | Ernst G, Bosio M, Salvado A, Dibur E, Nigro C, Borsini E. Difference between apnea-hypopnea index (AHI) and oxygen desaturation index (ODI): proportional increase associated with degree of obesity. Sleep Breath. 2016 Dec;20(4):1175-1183. doi: 10.1007/s11325-016-1330-3. Epub 2016 Mar 30. |
| 26333720 | Result | Camacho M, Robertson M, Abdullatif J, Certal V, Kram YA, Ruoff CM, Brietzke SE, Capasso R. Smartphone apps for snoring. J Laryngol Otol. 2015 Oct;129(10):974-9. doi: 10.1017/S0022215115001978. Epub 2015 Sep 3. |
| 24888483 | Result | Stippig A, Hubers U, Emerich M. Apps in sleep medicine. Sleep Breath. 2015 Mar;19(1):411-7. doi: 10.1007/s11325-014-1009-6. Epub 2014 Jun 3. |
| 14569523 | Result | Walker-Engstrom ML, Ringqvist I, Vestling O, Wilhelmsson B, Tegelberg A. A prospective randomized study comparing two different degrees of mandibular advancement with a dental appliance in treatment of severe obstructive sleep apnea. Sleep Breath. 2003 Sep;7(3):119-30. doi: 10.1007/s11325-003-0119-3. |
| 19451462 | Result | Lee CH, Mo JH, Choi IJ, Lee HJ, Seo BS, Kim DY, Yun PY, Yoon IY, Won Lee H, Kim JW. The mandibular advancement device and patient selection in the treatment of obstructive sleep apnea. Arch Otolaryngol Head Neck Surg. 2009 May;135(5):439-44. doi: 10.1001/archoto.2009.31. |
| 18482111 | Result | Petri N, Svanholt P, Solow B, Wildschiodtz G, Winkel P. Mandibular advancement appliance for obstructive sleep apnoea: results of a randomised placebo controlled trial using parallel group design. J Sleep Res. 2008 Jun;17(2):221-9. doi: 10.1111/j.1365-2869.2008.00645.x. |
| 27397661 | Result | Nerfeldt P, Friberg D. Effectiveness of Oral Appliances in Obstructive Sleep Apnea with Respiratory Arousals. J Clin Sleep Med. 2016 Aug 15;12(8):1159-65. doi: 10.5664/jcsm.6058. |
| D020919 |
| Sleep Disorders, Intrinsic |
| D020920 | Dyssomnias |
| D012893 | Sleep Wake Disorders |
| D009422 | Nervous System Diseases |
| D012135 | Respiratory Sounds |
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |