Time to defibrillation is the most important predictor of survival in cardiac arrest. Traditional emergency medical system response is often to slow. The aim of this study is to investigate the feasibility of drone systems that delivers Automated External Defibrillators (AED) to the scene of suspected Out-of-Hospital Cardiac Arrests (OHCA).
This study will test the feasibility of real-life flights with drones carrying automated external defibrillators (AEDs) to out-of-hospital cardiac arrest (OHCA) as a complement to standard care i.e EMS
We will test the feasibility of dispatching an out of sight AED-drone system to real-life OHCA in parallel with standard EMS dispatch. The study period is 5 months between May to September 2020. The study area will be covered by three individual drone systems covering some 80,000 inhabitants within the controlled airspace of Säve airport in Göteborg Sweden. Each drone system will have a flight range of six km.
The first month of the study period will be used as run-in period and the drone systems are dispatched for beyond visual line of sight (BVLOS) flights in a simulated fashion and optimized to decrease delays and to log pre-specified system variables, adherence to protocol, time delays, technological functionality, weather conditions, conflict in the airspace.
During the following 4 months June-September 2020, drones will dispatched to real-life suspected OHCA during daytime 08:00-22:00.
An EMS communication radio-unit is placed at the drone control center. In case of a suspected OHCA in the service area and will be alerted by the dispatch centre (SOS alarm) when a suspected OHCA is recognized during the 112-call.
Development of the technology is made by Everdrone AB Göteborg and SOS Alarm AB (national dispatch organisation) and parallel applications for certificates for the individual aircraft and permits for beyond visual line of sight flights (BVLOS-flights) was granted by the Swedish Transportation board on 27 April 2020.
The drone system is operated only during daytime 08:00-22:00 when the Airport Air traffic control is open. Likewise deployment of the drone will not be made if there is a conflict in the airspace with manned aircrafts. Rainy weather or winds exceeding 8 m/s prohibits flights as well.
Feasibility is evaluated and measured from the following aspects:
Proportions are measured out of cases where technological functionality prohibited mission completion a) no take-off b) aborted missions. (%)
Adverse advents (AE) and serious adverse events (SAE) in relation to AED-drone mission /use will be logged continuously. An adverse event may be caused by drone crash or risc of injury or death due to conflict in airspace or technological impairment.
An AE is considered serious if it:
Events that are related to the patient in cardiac arrest and would be expected in patients undergoing attempted resuscitation should NOT be reported. These include:
All events categorised as serious must be reported to the study administration within 24 hours of becoming aware of the event.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Delivery of automated external defibrillators using drones | Experimental | Three drone systems are setup to be deployed in suspected OHCA cases as a complement to EMS. This is a single-arm intervention evaluating feasibility in:
|
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Automated flying Drone carrying an Automated external defibrillator (AED) | Device | Totally n=3 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over 4 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation. |
| Measure | Description | Time Frame |
|---|---|---|
| Proportion of suspected OHCA cases (%) where the AED-drone was dispatched and accurately completed mission. | All cases of OHCA within the three service areas where the dispatch centre alerts the drone-operator and the drone takes-off. Accurate completion of mission equals deliver an AED onsite on the ground within 50 meters from OHCA location. AEDs shall be accessible to the bystander through T-CPR instructions given by the dispatcher. | Up to 4 months |
| Measure | Description | Time Frame |
|---|---|---|
| Proportion of suspected OHCA with AED-drone arrival prior to ambulance | Comparisons on proportion of units arriving first to the scene for ambulance vs AED-drone, percentages. | Up to 4 months |
| Time difference of drone arrival as compared to ambulance |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Andreas Claesson, PhD | Centre for resuscitation science, Karolinska Institutet | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Göteborg AED-drone service areas | Gothenburg | Sweden |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34438449 | Derived | Schierbeck S, Hollenberg J, Nord A, Svensson L, Nordberg P, Ringh M, Forsberg S, Lundgren P, Axelsson C, Claesson A. Automated external defibrillators delivered by drones to patients with suspected out-of-hospital cardiac arrest. Eur Heart J. 2022 Apr 14;43(15):1478-1487. doi: 10.1093/eurheartj/ehab498. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D058687 | Out-of-Hospital Cardiac Arrest |
| ID | Term |
|---|---|
| D006323 | Heart Arrest |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Totally n=3 AED-drones are deployed as a complement to standard care (EMS) in all cases of suspected OHCA occurring within service areas
Not provided
Not provided
Not provided
Not provided
|
Time delay from dispatch to arrival (delivered AED on ground), minutes, seconds.
| Up to 4 months |
| Proportion/numbers of attached drone delivered AEDs prior the arrival of EMS (%). | A bystander retrieves the AED as instructed in T-CPR protocol by the dispatcher and attaches it to the patient before ambulance arrival. Percentages. | Up to 4 months |