The aim of this study was to evaluate clinically and radiographically the splinted short implants' and single short implants' stability and bone condition before and after loading, in atrophic posterior mandibular alveolar ridges.
A prospective study was conducted on 16 Patients with missing posterior molars. Group A: 8 patients had 2 short implants placed in atrophic posterior mandibular alveolar ridge. Group B: 8 patients had a single short implant placed in atrophic posterior mandibular alveolar ridge.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Two short implants | Experimental | DENTIUM superline implant fixture is characterized by sandblasted with large grits and acid etched surface treatment (S.L.A). SLA surface allows good bone-implant contact with good clinical performance, maintaining crestal bone margin. Short Implants of 7.0 mm length and 4.5 mm diameter are to be used. The Short Implants are characterized by 1.5mm supra-bony smooth collar, and 5.5mm infra-bony surface treated double threaded titanium. |
|
| Single short implant | Active Comparator | DENTIUM superline implant fixture is characterized by sandblasted with large grits and acid etched surface treatment (S.L.A). SLA surface allows good bone-implant contact with good clinical performance, maintaining crestal bone margin. Short Implants of 7.0 mm length and 4.5 mm diameter are to be used. The Short Implants are characterized by 1.5mm supra-bony smooth collar, and 5.5mm infra-bony surface treated double threaded titanium. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Double short implant | Other | Patients receives 2 short implants to restore missing posterior teeth, loaded with splinted screw retained crowns. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Implant Stability | Implant stability was measured using Implant Stability Quotient (ISQ), a scale from 1 to 100. The ISQ scale has a non-linear correlation to micro-mobility. High stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability. | Immediately after the operation |
| Implant Stability | Implant stability was measured using Implant Stability Quotient (ISQ), a scale from 1 to 100. The ISQ scale has a non-linear correlation to micro-mobility. High stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability. | 3 months |
| Implant Stability | Implant stability was measured using Implant Stability Quotient (ISQ), a scale from 1 to 100. The ISQ scale has a non-linear correlation to micro-mobility. High stability means >70 ISQ, between 60-69 is medium stability and < 60 ISQ is considered as low stability. | 6 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of Dentistry, Alexandria University | Alexandria | 21527 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 10337319 | Background | Glantz PO, Nilner K. Biomechanical aspects of prosthetic implant-borne reconstructions. Periodontol 2000. 1998 Jun;17:119-24. doi: 10.1111/j.1600-0757.1998.tb00129.x. No abstract available. | |
| 16137095 | Background | Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S104-10. doi: 10.1111/j.1708-8208.2005.tb00082.x. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D016301 | Alveolar Bone Loss |
| ID | Term |
|---|---|
| D001862 | Bone Resorption |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
| D055093 | Periodontal Atrophy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Single short implant | Other | Patients receives single short implants, loaded with single screw retained crowns. |
|
| 5225747 | Background | Tallgren A. The reduction in face height of edentulous and partially edentulous subjects during long-term denture wear. A longitudinal roentgenographic cephalometric study. Acta Odontol Scand. 1966 Sep;24(2):195-239. doi: 10.3109/00016356609026127. No abstract available. |
| 22220770 | Background | Nevins M, Al Hezaimi K, Schupbach P, Karimbux N, Kim DM. Vertical ridge augmentation using an equine bone and collagen block infused with recombinant human platelet-derived growth factor-BB: a randomized single-masked histologic study in non-human primates. J Periodontol. 2012 Jul;83(7):878-84. doi: 10.1902/jop.2012.110478. Epub 2012 Jan 5. |
| 19885448 | Background | Chiapasco M, Casentini P, Zaniboni M. Bone augmentation procedures in implant dentistry. Int J Oral Maxillofac Implants. 2009;24 Suppl:237-59. |
| 16519186 | Background | das Neves FD, Fones D, Bernardes SR, do Prado CJ, Neto AJ. Short implants--an analysis of longitudinal studies. Int J Oral Maxillofac Implants. 2006 Jan-Feb;21(1):86-93. |
| 20977606 | Background | Neldam CA, Pinholt EM. State of the art of short dental implants: a systematic review of the literature. Clin Implant Dent Relat Res. 2012 Aug;14(4):622-32. doi: 10.1111/j.1708-8208.2010.00303.x. Epub 2010 Oct 26. |
| 25418606 | Background | Thoma DS, Haas R, Tutak M, Garcia A, Schincaglia GP, Hammerle CH. Randomized controlled multicentre study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures. Part 1: demographics and patient-reported outcomes at 1 year of loading. J Clin Periodontol. 2015 Jan;42(1):72-80. doi: 10.1111/jcpe.12323. Epub 2014 Dec 26. |
| 26804969 | Background | Lemos CA, Ferro-Alves ML, Okamoto R, Mendonca MR, Pellizzer EP. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis. J Dent. 2016 Apr;47:8-17. doi: 10.1016/j.jdent.2016.01.005. Epub 2016 Jan 19. |
| 16937587 | Background | Misch CE, Steignga J, Barboza E, Misch-Dietsh F, Cianciola LJ, Kazor C. Short dental implants in posterior partial edentulism: a multicenter retrospective 6-year case series study. J Periodontol. 2006 Aug;77(8):1340-7. doi: 10.1902/jop.2006.050402. |
| 21196883 | Background | Menchero-Cantalejo E, Barona-Dorado C, Cantero-Alvarez M, Fernandez-Caliz F, Martinez-Gonzalez JM. Meta-analysis on the survival of short implants. Med Oral Patol Oral Cir Bucal. 2011 Jul 1;16(4):e546-51. doi: 10.4317/medoral.16.e546. |
| 1811063 | Background | Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol. 1991;17(2):126-31. |
| D010510 |
| Periodontal Diseases |
| D009059 | Mouth Diseases |