The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion ("glucose plateau point", primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program.
Patients with type 1 DM using CSII require bolus insulin for two purposes: first, to cover carbohydrate intake to control postprandial glucose, and second, to correct episodes of hyperglycemia. The latter function is referred to as a "correction dose" or "correction bolus". Insulin pumps have bolus calculators which calculate correction doses based on the patient's individualized BG target and insulin sensitivity factor (ISF). Rapid-acting insulin analogues delivered by pump typically require 2 to 4 hours to fully correct an acute hyperglycemic episode, and sometimes multiple correction doses are needed to normalize the blood glucose level. This can be frustrating for patients, particularly when a correction bolus is necessary in addition to a meal bolus; frequently, patients must wait for the correction bolus to take effect and delay eating until the blood glucose has begun to normalize to avoid severe postprandial hyperglycemia. There is consequently an unmet need in insulin delivery, and in particular in CSII, for an insulin which can correct a hyperglycemic episode more rapidly than is currently possible with rapid-acting insulin analogues.
Faster insulin aspart (Fiasp) is a novel formulation of insulin aspart with an accelerated time-action profile which results in twice the exposure to insulin and 74% greater insulin action within the first 30 minutes after injection compared to conventional insulin aspart. This results in twice-as-fast onset of appearance in the bloodstream (4 vs. 9 min compared to conventional insulin aspart) which has been demonstrated to reduce postprandial glucose levels in patients with type 1 DM using CSII. Theoretically, this faster insulin action would be useful in correction dosing during acute episodes of hyperglycemia to normalize the blood glucose level more rapidly than is currently possible with conventional insulin aspart (NovoLog).
Many patients with type 1 DM using CSII now also use continuous glucose monitoring (CGM) for making insulin dosing decisions. Currently the FDA has approved 2 CGM systems for nonadjunctive use in bolus insulin dose calculations. Only one of these systems, the Dexcom, reads continuously to the patient and has alarms to warn of impending episodes of hyper- or hypoglycemia, and this is the system used most commonly by patients with type 1 DM using open-loop CSII. Patients now incorporate the Dexcom trend arrow, which depicts the rate and direction of glucose change, into the correction dose calculation, and recommendations on how to incorporate CGM information into correction dose calculations have recently been updated based on an expert consensus report. However, these guidelines were created for use with rapid acting insulin analogues. How they might need to be modified for use with Fiasp (the first and only ultra-rapid insulin analogue) is not known.
The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion ("glucose plateau point", primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program.
Study hypothesis:
Compared to conventional insulin aspart, Fiasp will correct hyperglycemia (defined as arrest of rise of blood glucose, following correction bolus, ie, GPP ) faster than conventional insulin aspart in subjects with type 1 DM using CSII.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| No Intervention: Conventional Insulin Aspart (NovoLogĀ®) | No Intervention | In the aspart group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Aspart is put into their pump and delivered to their body through a small tube placed under your skin. In this NovoLogĀ®-only treatment group, the subject will take aspart with each meal while your pump also gives you a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study. | |
| Faster Insulin Aspart (FiaspĀ®) | Active Comparator | In the Fiasp group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Fiasp is put into their pump and delivered to their body through a small tube placed under their skin. In this Fiasp treatment group, the subject will take fiasp with each meal while their pump also gives them a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Faster Insulin Aspart (FiaspĀ®) | Drug | Subjects will be randomized either to use Fiasp or conventional insulin aspart in CSII. CSII settings (basal, bolus, and correction factors) will be optimized using a meal challenge for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period. |
| Measure | Description | Time Frame |
|---|---|---|
| Time to stabilization of rising blood sugar by CGM after correction bolus | Time (in minutes) to stabilization of rising blood sugar (GPP) by CGM after correction bolus during the final 2 week maintenance period. Two categories of correction dose will be analyzed: 1) those following an isolated correction dose (taken independently of a meal dose), and 2) those taken as part of a combination bolus with a meal dose. | 2 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Incidence of early hypoglycemia | Incidence of early hypoglycemia (Blood glucose < 54 mg/dl within 1 and 2 hours) following correction bolus with each insulin (Key Safety Endpoint) | 25 weeks |
| Change in Insulin Sensitivity Factor |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Wendy S Lane, MD | Contact | 8286849588 | mountaindiabetes@msn.com | |
| Melinda L Buford, RN, BSN | Contact | 8286849588 | 314 | mbuford@mdecresearch.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mountain Diabetes and Endocrine Center | Recruiting | Asheville | North Carolina | 28803 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28055230 | Background | Bode BW, Johnson JA, Hyveled L, Tamer SC, Demissie M. Improved Postprandial Glycemic Control with Faster-Acting Insulin Aspart in Patients with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion. Diabetes Technol Ther. 2017 Jan;19(1):25-33. doi: 10.1089/dia.2016.0350. Epub 2017 Jan 5. | |
| 29344577 | Background |
Not provided
Not provided
Data and statistical analysis will be available to any researcher with appropriate request
post-study, up to 5 years
email Principal Investigator
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | Jan 7, 2019 | May 29, 2020 |
Not provided
This is a 25-week open-label prospective single center 2 arm crossover trial consisting of a CSII settings (basal, bolus, and correction factors) will be optimized for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period.
Not provided
Not provided
This is an open-label crossover trial. Subjects will be randomized to treatment sequence (Fiasp then NovoLog or NovoLog then Fiasp), each for a 12-week treatment period, by CSII. Randomization sequence will be determined by computerized randomization program. All patients will receive both treatments unless they drop out. Dropouts are unlikely since the participants are all regular continuing patients of the site's clinical practice.
Not provided
|
|
Change in Insulin Sensitivity Factor, if any, required for hypoglycemia prevention using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
| 25 weeks |
| Change in Insulin On Board | Change in Insulin On Board, if any, required for prevention of late hyperglycemia using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report | 25 weeks |
| GlycoMark differences between arms | GlycoMark (1,5 anhydroglucitol, a marker of postprandial glucose excursion) during use of each insulin. | 25 weeks |
| HbA1c differences between arms | HbA1c during use of each insulin | 25 weeks |
| Percent time spent in target range, hyperglycemic range, and hypoglycemic range | Percent time spent in target range, hyperglycemic range and hypoglycemic range by Continuous Glucose Monitoring (CGM) on each insulin during the final 2 weeks of each treatment period. Target ranges include 70-180 mg/dL. Hyperglycemia ranges to be captured will include Category 1: 181-250 mg/dL and Category 2: above 250 mg/dL. Hypoglycemia ranges to be captured include Category 1: 69-54 mg/dL and Category 2: below 54 mg/dL. | 4 weeks |
| Standard deviation differences between arms | Standard deviation of mean blood glucose as determined by CGM on each insulin | 4 weeks |
| Treatment related impact measures between arms | Treatment related impact measures on each insulin using TRIM D questionnaire | 6 weeks |
| Aleppo G, Laffel LM, Ahmann AJ, Hirsch IB, Kruger DF, Peters A, Weinstock RS, Harris DR. A Practical Approach to Using Trend Arrows on the Dexcom G5 CGM System for the Management of Adults With Diabetes. J Endocr Soc. 2017 Nov 20;1(12):1445-1460. doi: 10.1210/js.2017-00388. eCollection 2017 Dec 1. |
| 28205039 | Background | Heise T, Pieber TR, Danne T, Erichsen L, Haahr H. A Pooled Analysis of Clinical Pharmacology Trials Investigating the Pharmacokinetic and Pharmacodynamic Characteristics of Fast-Acting Insulin Aspart in Adults with Type 1 Diabetes. Clin Pharmacokinet. 2017 May;56(5):551-559. doi: 10.1007/s40262-017-0514-8. |
| 28356319 | Background | Russell-Jones D, Bode BW, De Block C, Franek E, Heller SR, Mathieu C, Philis-Tsimikas A, Rose L, Woo VC, Osterskov AB, Graungaard T, Bergenstal RM. Fast-Acting Insulin Aspart Improves Glycemic Control in Basal-Bolus Treatment for Type 1 Diabetes: Results of a 26-Week Multicenter, Active-Controlled, Treat-to-Target, Randomized, Parallel-Group Trial (onset 1). Diabetes Care. 2017 Jul;40(7):943-950. doi: 10.2337/dc16-1771. Epub 2017 Mar 29. |
| 27629148 | Background | Bergenstal RM, Garg S, Weinzimer SA, Buckingham BA, Bode BW, Tamborlane WV, Kaufman FR. Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes. JAMA. 2016 Oct 4;316(13):1407-1408. doi: 10.1001/jama.2016.11708. No abstract available. |
| 30537180 | Background | Klonoff DC, Evans ML, Lane W, Kempe HP, Renard E, DeVries JH, Graungaard T, Hyseni A, Gondolf T, Battelino T. A randomized, multicentre trial evaluating the efficacy and safety of fast-acting insulin aspart in continuous subcutaneous insulin infusion in adults with type 1 diabetes (onset 5). Diabetes Obes Metab. 2019 Apr;21(4):961-967. doi: 10.1111/dom.13610. Epub 2019 Jan 13. |
| Prot_000.pdf |
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| D006943 | Hyperglycemia |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D061267 | Insulin Aspart |
| ID | Term |
|---|---|
| D061266 | Insulin, Short-Acting |
| D061385 | Insulins |
| D010187 | Pancreatic Hormones |
| D036361 | Peptide Hormones |
| D006728 | Hormones |
| D006730 | Hormones, Hormone Substitutes, and Hormone Antagonists |
| D010455 | Peptides |
| D000602 | Amino Acids, Peptides, and Proteins |
Not provided
Not provided