The purpose of this prospective randomized controlled study is to evaluate the risk of asymptomatic cerebral embolism during catheter ablation of atrial fibrillation (AF) with AI-HPSD strategy versus standard radiofrequency ablation settings, with the diagnosis of asymptomatic cerebral embolism is determined by brain high-resolution diffusion-weighted magnetic resonance imaging technique.
Radiofrequency catheter ablation is increasingly performed in patients with paroxysmal and persistent atrial fibrillation (AF) in recent decade. However, catheter ablation of AF is associated with the occurrence of procedure-related thromboembolic events, especially the risk of asymptomatic cerebral embolism detected by brain high-resolution diffusion-weighted magnetic resonance imaging (hDWI). Meanwhile, ablation index guided high-power short-duration (AI-HPSD) strategy with the advanced SmartTouch SurroundFlow (STSF) catheter is an increasingly used technique for catheter ablation of AF, which is proposed to be associated with relatively wider and superficial lesions, less risk of esophageal injury, and shorter procedure time plus higher rate of first-pass pulmonary vein isolation. Moreover, the advanced STSF catheter in AI-HPSD strategy features with the Surround Flow entire tip irrigation system, which is a wide-spread distribution of the irrigating solution (56 irrigation holes), resulting in homogenous cooling and protection from thrombus formation and reduced incidence of steam pops. Thus, comparing with the standard radiofrequency ablation technique using the SmartTouch (ST) catheter, the AI-HPSD strategy may associate with much lower risk of periprocedural asymptomatic cerebral embolism, with the application of advanced STSF catheter and shorter procedure time. Therefore, this study is designed as a prospective randomized controlled study to evaluate the risk of asymptomatic cerebral embolism during catheter ablation of AF with AI-HPSD strategy versus standard radiofrequency ablation settings, with the diagnosis of asymptomatic cerebral embolism is determined by brain hDWI.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Ablation Index Guided High-Power Short-Duration Group | Experimental | For patients assigned to undergo AF ablation with ablation index guided high-power short-duration strategy, point-by-point circumferential pulmonary vein ablation will be performed using the advanced STSF catheter under ablation index guided high power short duration strategy (Radiofrequency energy is set up at a power of 50 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 20 mL/min; Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium). |
|
| Standard Radiofrequency Ablation Group | Active Comparator | For patients assigned to undergo AF ablation with standard radiofrequency ablation group, point-by-point circumferential pulmonary vein ablation will be performed using the ST catheter under standard radiofrequency ablation settings (Radiofrequency energy is set up at a power of 30 to 35 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 17 to 30 mL/min. Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ablation Index Guided High-Power Short-Duration Strategy | Procedure | Point-by-point circumferential pulmonary vein ablation will be performed using the advanced STSF catheter under ablation index guided high power short duration strategy (Radiofrequency energy is set up at a power of 50 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 20 mL/min; Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium). |
| Measure | Description | Time Frame |
|---|---|---|
| The incidence of new asymptomatic cerebral embolic lesions determined by hDWI. | The brain hDWI should be performed within 3 days prior to the ablation procedure to investigate previous cerebral lesions and reevaluated within 24-72 hours post ablation to determine the occurrence of new asymptomatic cerebral embolic lesions. The acute cerebral embolic lesion is typically defined as a new focal hyper-intense area detected on the diffusion-weighted sequence, and a hyper-intense signal intensity in the fluid-attenuated inversion recovery sequence, and meantime confirmed by apparent diffusion coefficient mapping as corresponding area of restricted diffusion to rule out a shine-through artifact. | Within 3 days prior to the ablation;24-72 hours after AF catheter ablation procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Cognitive functional status evaluated using the Montreal Cognitive Assessment (MoCA) test. | The Montreal Cognitive Assessment (MoCA) is known as a brief cognitive screening tool with a high sensitivity and specificity for detecting a mild cognitive impairment. All enrolled patients undergo a prospective assessment of their cognitive function using the MoCA test at 1 day before and 24-72 hours and 3 months after the catheter ablation procedure. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| The Second Affilliated Hospital of Chongqing Medical University | Chongqing | Chongqing Municipality | 400010 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30848001 | Background | Schmidt B, Szeplaki G, Merkely B, Kautzner J, van Driel V, Bourier F, Kuniss M, Bulava A, Nolker G, Khan M, Lewalter T, Klein N, Wenzel B, Chun JK, Shah D. Silent cerebral lesions and cognitive function after pulmonary vein isolation with an irrigated gold-tip catheter: REDUCE-TE Pilot study. J Cardiovasc Electrophysiol. 2019 Jun;30(6):877-885. doi: 10.1111/jce.13902. Epub 2019 Mar 25. | |
| 31937118 |
| Label | URL |
|---|---|
| Publications regarding the results of this Reduce-It Study. | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study is a single center prospective single-blinded randomized controlled trial. Enrolled AF patients planning clinically-indicated catheter ablation is randomly assigned with 1:1 ratio to undergo catheter ablation with ablation index guided high-power short-duration strategy or the standard radiofrequency ablation technique. Besides the evaluation at baseline, all the participants will be followed up at 24-72 hours, 1 month and 3 months post ablation.
Not provided
Not provided
Not provided
|
| Standard Radiofrequency Ablation Technique | Procedure | Point-by-point circumferential pulmonary vein ablation will be performed using the ST catheter under standard radiofrequency ablation settings (Radiofrequency energy is set up at a power of 30 to 35 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 17 to 30 mL/min. Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium). |
|
| On the 1 day before and 24-72 hours and 3 months after the catheter ablation procedure. |
| Overall complication rate during catheter ablation and up to 3 months follow up. | Overall complication rate after catheter ablation of AF. | 3 months after the catheter ablation procedure. |
| Background |
| Yu Y, Wang X, Li X, Zhou X, Liao S, Yang W, Yu J, Zhang F, Ju W, Chen H, Yang G, Li M, Gu K, Tang L, Xu Y, Chan JY, Kojodjojo P, Cao K, Fan J, Yang B, Chen M. Higher Incidence of Asymptomatic Cerebral Emboli After Atrial Fibrillation Ablation Found With High-Resolution Diffusion-Weighted Magnetic Resonance Imaging. Circ Arrhythm Electrophysiol. 2020 Jan;13(1):e007548. doi: 10.1161/CIRCEP.119.007548. Epub 2020 Jan 14. |
| 28340141 | Background | Providencia R, Albenque JP, Boveda S. The unfinished issue of ischaemic stroke and embolic events during catheter ablation of atrial fibrillation. Europace. 2017 May 1;19(5):881. doi: 10.1093/europace/euw027. No abstract available. |
| 26948985 | Background | Yamane T. Silent Cerebral Embolism After Catheter Ablation for Atrial Fibrillation - Unresolved Issue or Too Much Concern? Circ J. 2016;80(4):814-5. doi: 10.1253/circj.CJ-16-0186. Epub 2016 Mar 7. No abstract available. |
| 32147899 | Background | Kyriakopoulou M, Wielandts JY, Strisciuglio T, El Haddad M, Pooter J, Almorad A, Hilfiker G, Phlips T, Unger P, Lycke M, Vandekerckhove Y, Tavernier R, Duytschaever M, Knecht S. Evaluation of higher power delivery during RF pulmonary vein isolation using optimized and contiguous lesions. J Cardiovasc Electrophysiol. 2020 May;31(5):1091-1098. doi: 10.1111/jce.14438. Epub 2020 Mar 18. |
| 31713704 | Background | Castrejon-Castrejon S, Martinez Cossiani M, Ortega Molina M, Escobar C, Froilan Torres C, Gonzalo Bada N, Diaz de la Torre M, Suarez Parga JM, Lopez Sendon JL, Merino JL. Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study. J Interv Card Electrophysiol. 2020 Jan;57(1):57-65. doi: 10.1007/s10840-019-00645-5. Epub 2019 Nov 12. |
| 31600006 | Background | Okamatsu H, Koyama J, Sakai Y, Negishi K, Hayashi K, Tsurugi T, Tanaka Y, Nakao K, Sakamoto T, Okumura K. High-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation. J Cardiovasc Electrophysiol. 2019 Dec;30(12):2751-2758. doi: 10.1111/jce.14223. Epub 2019 Oct 21. |
| 31588620 | Background | Chen S, Schmidt B, Bordignon S, Urbanek L, Tohoku S, Bologna F, Angelkov L, Garvanski I, Tsianakas N, Konstantinou A, Trolese L, Weise F, Perrotta L, Chun KRJ. Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study. J Cardiovasc Electrophysiol. 2019 Dec;30(12):2724-2731. doi: 10.1111/jce.14219. Epub 2019 Oct 13. |
| 37996906 | Derived | Chen WJ, Gan CX, Cai YW, Liu YY, Xiao PL, Zou LL, Xiong QS, Qin F, Tao XX, Li R, Du HA, Liu ZZ, Yin YH, Ling ZY. Impact of high-power short-duration atrial fibrillation ablation technique on the incidence of silent cerebral embolism: a prospective randomized controlled study. BMC Med. 2023 Nov 23;21(1):461. doi: 10.1186/s12916-023-03180-3. |
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided