Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Ramathibodi Hospital | OTHER |
Not provided
Not provided
Not provided
Not provided
Inguinal hernia is one of the most-common surgical conditions. Incidence is about 27% in males and 3% in females.The treatment of this condition is inguinal hernia repair operation which can be approached with several techniques; open hernia repair, laparoscopic hernia repair and robotic hernia repair. The current guidelines recommend the hernia repair operation with mesh placement either Lichtenstenstein operation or laparoscopic technique; transabdominal preperitoneal technique (TAPP) and totally extraperitoneal technique (TEP). In the laparoscopic approach, one of the complications that can occur is post-operative pain from the mesh fixator. So the self-gripping mesh becomes another option to decrease this incidence.However the adhesive property of the mesh is still challenging for many surgeons. Several techniques of self-gripping mesh placement were introduced. One of the popular techniques is bilateral vertical folding of self-gripping mesh which still causes some adhesive problems when introduced to the target area. This research's aim is to present a new technique of the self-gripping mesh placement which is more effective, more convenient, and decreases the time taken to place the mesh at the surgery site.
A randomized control trail comparing the duration of mesh placement and surgeon satisfaction of self-gripping mesh with plastic sheath and with non-plastic sheath covering mesh. Patients with groin hernia who planned for elective laparoscopically repair hernia with self-gripping mesh at Ramathibodi Hospital, Faculty of Medicine, Mahidol University will are informed of the details of research at the outpatient department before admission. 1:1 open label randomization trail was designed dividing the patients into two groups by the study number. The operation will be done with the standard laparoscopic hernia repair technique by experienced surgeons.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| plastic sheath covering | Active Comparator | plastic sheath was prepared with the standard 9 cmx15cm self-gripping mesh. Then the meshe were folded and unfolded over or under the plastic sheaths in different directions. |
|
| mesh placement without plastic sheath | No Intervention | self-gripping mesh were placed without plastic sheath. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| self-gripping mesh placement with plastic sheath in laparoscopic inguinal hernia | Other | to apply these to the mesh graft placement process. In the first step, plastic sheaths self-gripping mesh placement with plastic sheathwere prepared configuration with the standard 9cmx15cm self-gripping mesh. Then the meshes were folded and unfolded over or under the plastic sheaths. |
| Measure | Description | Time Frame |
|---|---|---|
| Duration | the duration of self-gripping mesh placement with plastic sheath | 5 min |
| Measure | Description | Time Frame |
|---|---|---|
| post operative pain: pain scores | During a preoperative visit, the patients are introduced to the concept of the visual analogue scale (VAS), which ranges from 0 = no pain to 10 = worst pain. The measure pain scores (Visual Analog Scale) in the postoperative period. | 24 hours after surgery |
| wound infection |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Chairat Supsamutchai, MD | Contact | 66) 0851156958 | pogeneral2007@hotmai.com | |
| Chumpon Wilasrusmee, MD | Contact | (66)22011527 | 245 | chumpon.wil@mahidol.ac.th |
| Name | Affiliation | Role |
|---|---|---|
| Chairat Supsamutchai, MD | Ramathibodi Hospital, Mahidol University | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chairat Supsamutchai | Recruiting | Bangkok | Bankok | 10400 | Thailand |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A randomized control trail comparing the duration of mesh placement and surgeon satisfaction of self-gripping mesh with plastic sheath and with non-plastic sheath covering mesh. Patients with groin hernia who planned for elective laparoscopically repair hernia with self-gripping mesh at Ramathibodi Hospital, Faculty of Medicine, Mahidol University will are informed of the details of research at the outpatient department before admission. 1:1 open label randomization trail was designed dividing the patients into two groups by the study number. The operation will be done with the standard laparoscopic hernia repair technique by experienced surgeons.
Not provided
Not provided
Not provided
Not provided
|
wound infection |
| 30 days |