As the number of implanted cardiovascular implanted electronic devices (CIEDs) increases, the incidence of their complications also grows. Pocket hematoma is an important complication of CIED implantation, which has been reported in 2.9-9.5% of CIEDs patients. Pocket hematoma can cause significant pain and interfere with proper wound healing, and it also increased the risk of infection and may prolong length of stay.
Pocket compression is usually applied to compress bleeding vessels and reduce bleeding after implantation. A conventional compression method is to place a sandbag over the pocket, and then using adhesive tape to fix the sandbag. Due to adhesive tape is elastic and the tape may be pulled by patients' activity, sandbag easily migrated from the site. Therefore, nurse must readjust the position of sandbag, or even remove the adhesive tape and perform re-compress. Furthermore, adhesive tape can cause skin erosion. All of which not only result in patients' discomfort and dissatisfaction, but also increase the burden on nurses and wastes resources.
We designed a pocket compression fixation belt. We assumed that using this fixation belt can ensure the compression effect while avoiding sand bag displacement, reducing skin erosion and decrease the workload of care.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pocket compression fixation belt | Experimental | Pocket compression belt is used to compress the bleeding vessels and reduce bleeding after implantation. |
|
| Sand bag compression | Active Comparator | Sand bag compression is used to compress the bleeding vessels and reduce bleeding after implantation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| pocket compression fixation belt | Device | Pocket compression fixation belt to is used to compress the postoperative wounds of CIEDS patients, and its effect of preventing hematoma is evaluated. |
| Measure | Description | Time Frame |
|---|---|---|
| The incidence and grade of pocket hematoma | The incidence and grade of pocket hematoma between the control and experimental group were compared | 48 hours post implantation of ICEDs. |
| Measure | Description | Time Frame |
|---|---|---|
| Operation time and positional adjustment of the sandbag | Operation time refer to the consuming minutes that perform compression procedure for each patient, including the total time to fix the salt bag and remove the salt bag twice during intermittent compression. | Accumulate the time used to place and adjust the salt bag within 48 hours for each patient. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Jingwen Hu, Master | Contact | 008618991232872 | jingwenhu@163.com |
| Name | Affiliation | Role |
|---|---|---|
| Jingwen Hu, Master | First Affiliated Hospital Xi'an Jiaotong University | Study Chair |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23265327 | Background | Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO, Tracy CM, Epstein AE, Darbar D, DiMarco JP, Dunbar SB, Estes NA 3rd, Ferguson TB Jr, Hammill SC, Karasik PE, Link MS, Marine JE, Schoenfeld MH, Shanker AJ, Silka MJ, Stevenson LW, Stevenson WG, Varosy PD; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines; Heart Rhythm Society. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2013 Jan 22;61(3):e6-75. doi: 10.1016/j.jacc.2012.11.007. Epub 2012 Dec 19. No abstract available. | |
| 23801827 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Background |
| European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA); Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013 Aug;15(8):1070-118. doi: 10.1093/europace/eut206. Epub 2013 Jun 24. No abstract available. |
| 28919379 | Background | Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, Cha YM, Clancy J, Deharo JC, Ellenbogen KA, Exner D, Hussein AA, Kennergren C, Krahn A, Lee R, Love CJ, Madden RA, Mazzetti HA, Moore JC, Parsonnet J, Patton KK, Rozner MA, Selzman KA, Shoda M, Srivathsan K, Strathmore NF, Swerdlow CD, Tompkins C, Wazni O. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017 Dec;14(12):e503-e551. doi: 10.1016/j.hrthm.2017.09.001. Epub 2017 Sep 15. No abstract available. |
| 28903470 | Background | Raatikainen MJP, Arnar DO, Merkely B, Nielsen JC, Hindricks G, Heidbuchel H, Camm J. A Decade of Information on the Use of Cardiac Implantable Electronic Devices and Interventional Electrophysiological Procedures in the European Society of Cardiology Countries: 2017 Report from the European Heart Rhythm Association. Europace. 2017 Aug 1;19(suppl_2):ii1-ii90. doi: 10.1093/europace/eux258. |
| 25855676 | Background | Sridhar AR, Yarlagadda V, Yeruva MR, Kanmanthareddy A, Vallakati A, Dawn B, Lakkireddy D. Impact of haematoma after pacemaker and CRT device implantation on hospitalization costs, length of stay, and mortality: a population-based study. Europace. 2015 Oct;17(10):1548-54. doi: 10.1093/europace/euv075. Epub 2015 Apr 7. |
| 23407627 | Background | Palmisano P, Accogli M, Zaccaria M, Luzzi G, Nacci F, Anaclerio M, Favale S. Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy. Europace. 2013 Apr;15(4):531-40. doi: 10.1093/europace/eus337. Epub 2013 Feb 13. |
| 21365264 | Background | Sohail MR, Hussain S, Le KY, Dib C, Lohse CM, Friedman PA, Hayes DL, Uslan DZ, Wilson WR, Steckelberg JM, Baddour LM; Mayo Cardiovascular Infections Study Group. Risk factors associated with early- versus late-onset implantable cardioverter-defibrillator infections. J Interv Card Electrophysiol. 2011 Aug;31(2):171-83. doi: 10.1007/s10840-010-9537-x. Epub 2011 Mar 2. |
| 28543543 | Background | Koh Y, Bingham NE, Law N, Le D, Mariani JA. Cardiac implantable electronic device hematomas: Risk factors and effect of prophylactic pressure bandaging. Pacing Clin Electrophysiol. 2017 Jul;40(7):857-867. doi: 10.1111/pace.13106. Epub 2017 Jun 14. |
| 20048212 | Background | Baddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB, Masoudi FA, Okum EJ, Wilson WR, Beerman LB, Bolger AF, Estes NA 3rd, Gewitz M, Newburger JW, Schron EB, Taubert KA; American Heart Association Rheumatic Fever, Endocarditis, and Kawasaki Disease Committee; Council on Cardiovascular Disease in Young; Council on Cardiovascular Surgery and Anesthesia; Council on Cardiovascular Nursing; Council on Clinical Cardiology; Interdisciplinary Council on Quality of Care; American Heart Association. Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association. Circulation. 2010 Jan 26;121(3):458-77. doi: 10.1161/CIRCULATIONAHA.109.192665. Epub 2010 Jan 4. |
| 33675448 | Derived | Hu J, Zheng J, Liu X, Li G, Xiao X. Effect of a pocket compression device on hematomas, skin reactions, and comfort in patients receiving a cardiovascular implantable electronic device: a randomized controlled trial. J Interv Card Electrophysiol. 2022 Mar;63(2):275-281. doi: 10.1007/s10840-021-00973-5. Epub 2021 Mar 6. |