The investigators propose evaluating the feasibility of using the novel cone beam computed tomography (CBCT)-guided Ethos system to deliver expedited, adaptive Quad shot radiation for the purpose of palliative radiation of patients with advanced head and neck cancers or patients with a history of any malignancy experiencing current head and neck lesions. Quad shot radiation was selected as the palliative regimen of choice given its low toxicity profile, well published efficacy in palliation, frequent usage in the US for palliation of head and neck cancers, and safety in the setting of re-irradiation. The use of the Ethos platform to perform online adaptive radiation planning and delivery remains novel and untested. The Ethos system would be used to consolidate CT simulation, replanning, and treatment for Quad shot patients receiving treatment with the benefit of reduced patient travel and a reduction in the unwanted delay between Quad shot cycles. The goal of this pilot study will be to evaluate the feasibility of the Ethos system to eliminate the need for a CT simulation for cycles 2 and 3 of Quad shot radiation.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Quad shot radiation | Experimental | -Radiotherapy will consist of Quad shot radiation delivered on the Ethos ring gantry kV-CBCT combined with linear accelerator system to a dose of 14 Gy in four, twice-daily fractions of 3.5 Gy delivered at least 6 hours apart over two days for a possible total of 3 cycles delivered in 3 to 4 intervals for a cumulative dose of of 42 Gy in 12 fractions. Cycle 2 and 3 of treatment is not mandated per protocol but may be given at the discretion of the treating physician. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ring gantry kV-CBCT combined with linear accelerator (Halcyon) | Device | -Varian Medical Systems is the manufacturer |
|
| Measure | Description | Time Frame |
|---|---|---|
| Feasibility as measured by the successful completion of Quad shot radiation using CBCT instead of routine CT simulation in 80% of attempted simulated patients | Completion of treatment by all patients enrolled (estimated to be 3 years and 12 weeks) |
| Measure | Description | Time Frame |
|---|---|---|
| Average time (days) required from initial consult to completion of radiation therapy for patient travel and visits to the department | Approximately 12 weeks | |
| Percentage of patients from whom repeat CT simulation was eliminated | Completion of treatment by all patients enrolled (estimated to be 3 years and 12 weeks) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
-Pregnant and/or breastfeeding. Women of childbearing potential must have a negative pregnancy test within 14 days of study entry. If pregnancy test is not clinically indicated as determined by treating physician or protocol PI, documentation of this exception is sufficient in lieu of pregnancy test.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Wade Thorstad, M.D. | Washington University School of Medicine | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Washington University School of Medicine | St Louis | Missouri | 63110 | United States |
Not provided
| Label | URL |
|---|---|
| Alvin J. Siteman Cancer Center at Barnes-Jewish Hospital and Washington University School of Medicine | View source |
Not provided
The investigators will provide a summary of basic outcomes and clinical results within one year.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006258 | Head and Neck Neoplasms |
| ID | Term |
|---|---|
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
Not provided
Not provided
| ID | Term |
|---|---|
| D010315 | Particle Accelerators |
| ID | Term |
|---|---|
| D055618 | Radiation Equipment and Supplies |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Quad shot radiation | Radiation | Treatment of each cycle should ideally take place on two consecutive days. Allowing for holidays, weekends, and other scheduling issues or unexpected delays, treatment may be completed within five calendar days. |
|