Measurement algorithm control and optimization with subsequent performance evaluation of Sanmina biosensors in monitoring of glucose, heart rate (HR), and SpO2 in patients with type 1 and type 2 diabetes during a standardized meal experiment.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Optimization and control 1 | Experimental | The first study part/arm includes 12 patients and will be used for optimization and control of the measurement algorithms of the Sanmina biosensors. |
|
| Optimization and control 2 | Experimental | The second study part/arm includes 12 patients and will be used for optimization and control of the measurement algorithms of the Sanmina biosensors. |
|
| Precision and accuracy | Other | During the third study part with enrolment of 36 patients, the precision and accuracy of the final Sanmina biosensor algorithm will be demonstrated. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sanmina Biosensor | Device | non-invasive blood glucose measurement using the Sanmina Biosensor referenced with the invasive reference blood glucose device YSI 2400 Plus. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Performance and accuracy of glucose levels | performance and accuracy of the Sanmina biosensors (wearable and finger clip) in monitoring glucose levels (mg/dL) during a standardized meal experiment. Measurements (during the meal experiment) of the Sanmina biosensor will be compared to the capillary blood glucose reference method YSI STAT 2300 (glucose, in mg/dL). | approx. 240 minutes |
| Performance and accuracy of pO2 | performance and accuracy of the Sanmina biosensors (wearable and finger clip) in monitoring pO2 (%) during a standardized meal experiment. PO2-measurements (during the meal experiment) of the Sanmina biosensor will be compared to the patient monitor (%). | approx. 240 minutes |
| Performance and accuracy of heart rate | performance and accuracy of the Sanmina biosensors (wearable and finger clip) in monitoring heart rate (pulse/min) during a standardized meal experiment. Heart rate measurements (during the meal experiment) of the Sanmina biosensor will be compared to the patient monitor heart rate(pulse/min). | approx. 240 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Pfuetzner Science & Health Institute GmbH | Mainz | Rhineland-Palatinate | 55128 | Germany |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The first 2 study parts include 12 patients each. In the third study part 36 patients will be enrolled. Study part 1 and 2 will be used for optimization and control of the measurement algorithms of the Sanmina biosensors. During the third study part with enrolment of 36 patients, the precision and accuracy of the final Sanmina biosensor algorithm will be demonstrated.