Pressure offloading is often considered the most crucial aspect in healing after a foot injury. The investigators have devised a novel foot offloading device (PopSole™) which will allow for customization of the area where there is foot pain, as well as allow for customizable arch support and elevation of the metatarsals. This validation study is aimed to assess improvement of pain with use, ease of use, fit and feel, compliance, and durability over a 4 week period. Validated patient reported outcome measures will be used at baseline, 2 weeks and 4 weeks.
All subjects will receive the PopSole™ offloading device at the screening/baseline visit, be asked to wear it for 4 weeks, and will be asked to return for an in-person evaluation at week 2 and a completion study visit at week 4.
Screening includes the following procedures:
Subjects will be asked to complete:
Questionnaires
Diary cards to document for the feet: pain, bruising, redness of the skin, itching, swelling, bleeding, and any concerns/issues not listed, as well as the location, date and day for each noted symptom.
Offload Device Distribution. Devices will be provided for both feet to maintain symmetry and gait stability between the two feet. One pair of devices will be given for use in shoe gear, and one pair will be given for use in a slide in the shower.
Follow up visit procedures:
Week 2
Week 4
The same procedures listed for week 2, with the addition of PopSole™ Device removal and final foot diary card collection.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PopSole™ offloading device | Experimental | This is an external insole device that fits into a shoe and is reusable for a given subject, not for one-time use. It is comparable to other off-the-shelf insoles readily available and presents minimal risk to the participant during the four weeks of study participation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PopSole™ Offloading Device | Device | Specifically, the PopSole™ Offloading Device allows the provider to pop bubbles in the device (like popping paper or plastic bubble sheeting), thereby offloading the surgical area or area of pain. This customizable approach to offloading may increase compliance as it can easily fit in a normal walking shoe and is personalized for each patient. It can also be attached to a slide for use in the shower. Currently no post-operative devices for offloading the foot can be used in the shower. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Pittsburgh Foot Survey. | Pain and function questionnaire measure. Scale for pain ranges from "Very severe" to "Had no pain". Scale for pain interference ranges from " Very much" to "not at all". Scale of functionality ranges from "unable to do" to "without any difficulty" in regards to a range of specified activities. Change is reported in mean foot reported pain score Screening/Baseline visit to 4 Week visit. Questions related to pain include items 1-5, total pain score possible is 25; higher scores indicate less pain reported. | Four Weeks |
| Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Manchester Foot and Ankle Index. | Pain and function questionnaire assessment. Three responses to a variety of pain and specified activities raging from "On most/every day(s)" which is scored as 2 to "none of the time" which is scored as 0. Summation is made on Functional (0-20 with 20 being the lowest functioning), Personal appearance (0-4 with 4 being the worst), pain (0-10 with 10 being the worst), work/leisure (0-100 with 100 being the worst impact on work/leisure). Change in mean foot pain as reported on the Manchester Foot and Ankle Index from Screening/Baseline visit to 4 Week visit. Pain subscale is questions 13-17, range is 0-10 total points, lower scores indicate less pain. | Four Weeks |
| Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Mayo Clinical Scoring System Questionnaire. | Pain and function questionnaire. Pain scale from 0 (worst) to 50 (no pain). Activity limitations, orthotic requirements, antalgic gait, neuropathy and plantar heel tenderness are all graded 10 (best) to 10 (worst). Overall summation is excellent (90-100), good (80-89), fair (70-79), poor (<70). Change in mean foot pain score on Mayo Clinical Scoring System Questionnaire from Screening/Baseline Visit to 4 Week Visit. Pain scale is the first question, 50 total points, with higher scores meaning less pain. | Four Weeks |
| Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale. |
| Measure | Description | Time Frame |
|---|---|---|
| Participants' Reported Satisfaction and/or Difficulties With the Device | As measured by subject self report, using a device satisfaction measure questionnaire. Questions are answered yes/no in all cases except comfort (1-10 with 10 being the most comfortable), and ease of use (1-10 with 10 being most easy to use). | Four Weeks |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jeffrey Gusenoff, MD | Professor of Plastic Surgery, Director of the Foot Fat Grafting Institute | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| UPMC Aesthetic Plastic Surgery Center | Pittsburgh | Pennsylvania | 15213 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27391833 | Background | Gusenoff JA, Mitchell RT, Jeong K, Wukich DK, Gusenoff BR. Autologous Fat Grafting for Pedal Fat Pad Atrophy: A Prospective Randomized Clinical Trial. Plast Reconstr Surg. 2016 Nov;138(5):1099-1108. doi: 10.1097/PRS.0000000000002667. | |
| 30204683 | Background | Minteer DM, Gusenoff BR, Gusenoff JA. Fat Grafting for Pedal Fat Pad Atrophy in a 2-Year, Prospective, Randomized, Crossover, Single-Center Clinical Trial. Plast Reconstr Surg. 2018 Dec;142(6):862e-871e. doi: 10.1097/PRS.0000000000005006. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
1 participant was a screen failure and was not found eligible to continue to intervention.
10 participants were recruited to a 1 month cohort, and 10 participants to a 3 month cohort.
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | PopSole™ Offloading Device | This is an external insole device that fits into a shoe and is reusable for a given subject, not for one-time use. It is comparable to other off-the-shelf insoles readily available and presents minimal risk to the participant during the four weeks of study participation. PopSole™ Offloading Device: Specifically, the PopSole™ Offloading Device allows the provider to pop bubbles in the device (like popping paper or plastic bubble sheeting), thereby offloading the surgical area or area of pain. This customizable approach to offloading may increase compliance as it can easily fit in a normal walking shoe and is personalized for each patient. It can also be attached to a slide for use in the shower. Currently no post-operative devices for offloading the foot can be used in the shower. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | PopSole™ Offloading Device | This is an external insole device that fits into a shoe and is reusable for a given subject, not for one-time use. It is comparable to other off-the-shelf insoles readily available and presents minimal risk to the participant during the four weeks of study participation. PopSole™ Offloading Device: Specifically, the PopSole™ Offloading Device allows the provider to pop bubbles in the device (like popping paper or plastic bubble sheeting), thereby offloading the surgical area or area of pain. This customizable approach to offloading may increase compliance as it can easily fit in a normal walking shoe and is personalized for each patient. It can also be attached to a slide for use in the shower. Currently no post-operative devices for offloading the foot can be used in the shower. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Categorical | Count of Participants |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Pittsburgh Foot Survey. | Pain and function questionnaire measure. Scale for pain ranges from "Very severe" to "Had no pain". Scale for pain interference ranges from " Very much" to "not at all". Scale of functionality ranges from "unable to do" to "without any difficulty" in regards to a range of specified activities. Change is reported in mean foot reported pain score Screening/Baseline visit to 4 Week visit. Questions related to pain include items 1-5, total pain score possible is 25; higher scores indicate less pain reported. | 19 participants received the study device, 15 completed a 4 week visit. | Posted | Mean | 95% Confidence Interval | Score on a scale | Four Weeks |
|
Adverse events were assessed at each timepoint, over a period of 1 month for the first cohort, and over a period of 3 months for the second cohort.
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | PopSole™ Offloading Device | This is an external insole device that fits into a shoe and is reusable for a given subject, not for one-time use. It is comparable to other off-the-shelf insoles readily available and presents minimal risk to the participant during the four weeks of study participation. PopSole™ Offloading Device: Specifically, the PopSole™ Offloading Device allows the provider to pop bubbles in the device (like popping paper or plastic bubble sheeting), thereby offloading the surgical area or area of pain. This customizable approach to offloading may increase compliance as it can easily fit in a normal walking shoe and is personalized for each patient. It can also be attached to a slide for use in the shower. Currently no post-operative devices for offloading the foot can be used in the shower. |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| pain at left metatarsal on left foot | General disorders | Systematic Assessment | Subject reported moderate pain to investigators, determined to be unrelated to Popsole device, resolved without sequelae within 2 days of onset. |
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Jeffrey Gusenoff, MD | University of Pittsburgh | (412) 641-3960 | gusenoffja@upmc.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Dec 10, 2021 | Sep 21, 2022 | Prot_SAP_001.pdf |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D036981 | Fasciitis, Plantar |
| ID | Term |
|---|---|
| D005208 | Fasciitis |
| D009140 | Musculoskeletal Diseases |
| D005534 | Foot Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
This survey assesses pain (40 points possible, comprises pain subtotal), function (50 points possible, comprises function subtotal; which includes activity limitations, maximum walking distance, difficulty with walking surfaces, gait abnormality, sagittal motion, hindfoot motion and ankle/hindfoot stability, and alignment (10 possible points, comprises alignment subtotal). A total score is calculated out of 100, with higher scores indicating greater impairment. There are also calculated subtotals specific to pain, function and alignment. Change in mean foot pain score on AOFAS from Screening/Baseline Visit to 4 Week Visit. Pain scale is 40 total points, with higher scores meaning less pain. |
| Four Weeks |
| Device Durability | Documentation of the number of participants who wore a single device for first 4 weeks of the participant's study participation. | Four weeks. |
| Participant Compliance With Device | Documentation of the number of participants who did not wear a single device for the full 4 weeks of the participant's study participation. | Four Weeks |
| 26592234 | Background | Swinnen E, Kerckhofs E. Compliance of patients wearing an orthotic device or orthopedic shoes: A systematic review. J Bodyw Mov Ther. 2015 Oct;19(4):759-70. doi: 10.1016/j.jbmt.2015.06.008. Epub 2015 Jul 2. |
| 30254428 | Background | Jarl G. Methodological considerations of investigating adherence to using offloading devices among people with diabetes. Patient Prefer Adherence. 2018 Sep 12;12:1767-1775. doi: 10.2147/PPA.S175738. eCollection 2018. |
| 23321218 | Background | Waaijman R, Keukenkamp R, de Haart M, Polomski WP, Nollet F, Bus SA. Adherence to wearing prescription custom-made footwear in patients with diabetes at high risk for plantar foot ulceration. Diabetes Care. 2013 Jun;36(6):1613-8. doi: 10.2337/dc12-1330. Epub 2013 Jan 15. |
| 28320425 | Background | Polat G, Karademir G, Akalan E, Asik M, Erdil M. Patient compliance with touchdown weight bearing after microfracture treatment of talar osteochondral lesions. J Orthop Surg Res. 2017 Mar 20;12(1):46. doi: 10.1186/s13018-017-0548-5. |
| 24356801 | Background | Arts ML, de Haart M, Bus SA, Bakker JP, Hacking HG, Nollet F. Perceived usability and use of custom-made footwear in diabetic patients at high risk for foot ulceration. J Rehabil Med. 2014 Apr;46(4):357-62. doi: 10.2340/16501977-1272. |
| 19217785 | Background | Bus SA, van Deursen RW, Kanade RV, Wissink M, Manning EA, van Baal JG, Harding KG. Plantar pressure relief in the diabetic foot using forefoot offloading shoes. Gait Posture. 2009 Jun;29(4):618-22. doi: 10.1016/j.gaitpost.2009.01.003. Epub 2009 Feb 13. |
| 20961763 | Background | Wunnemann M, Klein D, Rosenbaum D. Effects of the Twin Shoe (Darco) to compensate height differences in normal gait. Gait Posture. 2011 Jan;33(1):61-5. doi: 10.1016/j.gaitpost.2010.09.025. Epub 2010 Oct 20. |
| 16300949 | Background | Myers KA, Long JT, Klein JP, Wertsch JJ, Janisse D, Harris GF. Biomechanical implications of the negative heel rocker sole shoe: gait kinematics and kinetics. Gait Posture. 2006 Nov;24(3):323-30. doi: 10.1016/j.gaitpost.2005.10.006. Epub 2005 Nov 21. |
| 28421239 | Background | Braun BJ, Veith NT, Rollmann M, Orth M, Fritz T, Herath SC, Holstein JH, Pohlemann T. Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole. Int Orthop. 2017 Aug;41(8):1507-1512. doi: 10.1007/s00264-017-3481-7. Epub 2017 Apr 19. |
| 28985487 | Background | Bus SA, Maas JC, Otterman NM. Lower-extremity dynamics of walking in neuropathic diabetic patients who wear a forefoot-offloading shoe. Clin Biomech (Bristol). 2017 Dec;50:21-26. doi: 10.1016/j.clinbiomech.2017.10.003. Epub 2017 Oct 2. |
| 25614503 | Background | Robinson C, Major MJ, Kuffel C, Hines K, Cole P. Orthotic management of the neuropathic foot: an interdisciplinary care perspective. Prosthet Orthot Int. 2015 Feb;39(1):73-81. doi: 10.1177/0309364614545422. |
| 28804593 | Background | Jarl G, Tranberg R. An innovative sealed shoe to off-load and heal diabetic forefoot ulcers - a feasibility study. Diabet Foot Ankle. 2017 Jul 25;8(1):1348178. doi: 10.1080/2000625X.2017.1348178. eCollection 2017. |
| 26654736 | Background | de Oliveira AL, Moore Z. Treatment of the diabetic foot by offloading: a systematic review. J Wound Care. 2015 Dec;24(12):560, 562-70. doi: 10.12968/jowc.2015.24.12.560. |
| 27556758 | Background | Bus SA. The Role of Pressure Offloading on Diabetic Foot Ulcer Healing and Prevention of Recurrence. Plast Reconstr Surg. 2016 Sep;138(3 Suppl):179S-187S. doi: 10.1097/PRS.0000000000002686. |
| 18316713 | Background | Janisse DJ, Janisse E. Shoe modification and the use of orthoses in the treatment of foot and ankle pathology. J Am Acad Orthop Surg. 2008 Mar;16(3):152-8. doi: 10.5435/00124635-200803000-00006. |
| 30007274 | Background | Farber SE, Minteer D, Gusenoff BR, Gusenoff JA. The Influence of Fat Grafting on Skin Quality in Cosmetic Foot Grafting: A Randomized, Cross-Over Clinical Trial. Aesthet Surg J. 2019 Mar 14;39(4):405-412. doi: 10.1093/asj/sjy168. |
| 34840921 | Result | Lubarsky R, Gusenoff B, Gusenoff JA. Prospective Cohort Validation Study of a Novel Foot Offloading Device. Plast Reconstr Surg Glob Open. 2021 Nov 24;9(11):e3950. doi: 10.1097/GOX.0000000000003950. eCollection 2021 Nov. |
| University Required, Research Covid Shut Down |
|
| Participants |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Number of participants who received PopSole device at baseline | Count of Participants | Participants |
|
|
|
|
| Primary | Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Manchester Foot and Ankle Index. | Pain and function questionnaire assessment. Three responses to a variety of pain and specified activities raging from "On most/every day(s)" which is scored as 2 to "none of the time" which is scored as 0. Summation is made on Functional (0-20 with 20 being the lowest functioning), Personal appearance (0-4 with 4 being the worst), pain (0-10 with 10 being the worst), work/leisure (0-100 with 100 being the worst impact on work/leisure). Change in mean foot pain as reported on the Manchester Foot and Ankle Index from Screening/Baseline visit to 4 Week visit. Pain subscale is questions 13-17, range is 0-10 total points, lower scores indicate less pain. | 19 participants received the study device, 15 completed a 4 week visit. | Posted | Mean | 95% Confidence Interval | Score on a scale. | Four Weeks |
|
|
|
|
| Primary | Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the Mayo Clinical Scoring System Questionnaire. | Pain and function questionnaire. Pain scale from 0 (worst) to 50 (no pain). Activity limitations, orthotic requirements, antalgic gait, neuropathy and plantar heel tenderness are all graded 10 (best) to 10 (worst). Overall summation is excellent (90-100), good (80-89), fair (70-79), poor (<70). Change in mean foot pain score on Mayo Clinical Scoring System Questionnaire from Screening/Baseline Visit to 4 Week Visit. Pain scale is the first question, 50 total points, with higher scores meaning less pain. | 19 participants received the study device. 15 completed a 4 Week visit. | Posted | Mean | 95% Confidence Interval | score on a scale | Four Weeks |
|
|
|
|
| Primary | Change in Foot Pain From Screening/Baseline Visit to 4 Week Visit as Reported on the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale. | This survey assesses pain (40 points possible, comprises pain subtotal), function (50 points possible, comprises function subtotal; which includes activity limitations, maximum walking distance, difficulty with walking surfaces, gait abnormality, sagittal motion, hindfoot motion and ankle/hindfoot stability, and alignment (10 possible points, comprises alignment subtotal). A total score is calculated out of 100, with higher scores indicating greater impairment. There are also calculated subtotals specific to pain, function and alignment. Change in mean foot pain score on AOFAS from Screening/Baseline Visit to 4 Week Visit. Pain scale is 40 total points, with higher scores meaning less pain. | 19 participants received the study device. 15 completed a 4 Week visit. | Posted | Mean | 95% Confidence Interval | score on a scale | Four Weeks |
|
|
|
|
| Primary | Device Durability | Documentation of the number of participants who wore a single device for first 4 weeks of the participant's study participation. | 19 participants received the study device at baseline. 1 participant withdrew prior to the four week, 2 participants were withdrawn from the study due to the University of Pittsburgh's ordered research shutdown due to Covid, and one participant missed the four week visit. | Posted | Count of Participants | Participants | Four weeks. |
|
|
|
| Primary | Participant Compliance With Device | Documentation of the number of participants who did not wear a single device for the full 4 weeks of the participant's study participation. | 19 participants received the study device at baseline. 1 participant withdrew prior to the four week, 2 participants were withdrawn from the study due to the University of Pittsburgh's ordered research shutdown due to Covid, and one participant missed the four week visit. | Posted | Count of Participants | Participants | Four Weeks |
|
|
|
| Secondary | Participants' Reported Satisfaction and/or Difficulties With the Device | As measured by subject self report, using a device satisfaction measure questionnaire. Questions are answered yes/no in all cases except comfort (1-10 with 10 being the most comfortable), and ease of use (1-10 with 10 being most easy to use). | Participants reported comfort with the PopSole Device on a 1-10 scale, 1= very uncomfortable and 10=very comfortable. Participants reported on the ease of using the PopSole Device on 1-10 scale, 1=very difficult and 10=very easy. 20 total points possible, higher score indicates increased satisfaction. | Posted | Mean | Standard Deviation | score on a scale | Four Weeks |
|
|
|
|
| 0 |
| 20 |
| 0 |
| 20 |
| 1 |
| 20 |
|
Not provided
Not provided