During percutaneous cardiovascular intervention, temporary cardiac stimulation may be required. Usually this stimulation is generated via a temporary pacing catheter. In order to reduce the complexity of the procedure, a new stimulation strategy has been developed: the "Direct Wire Pacing technique".In this approach, the cardiac stimulation is provided via the guidewire connected to an external pacemaker.
Previous study demonstrated the superiority of the new technique compared to the former. However this technique is likely to generate electrical pain, risk of bleeding for the patient and risk of blood exposure accident for the operators. This is why the medical device ELECTRODUCER SLEEVE has been developed. This device integrates a pacing function to the introducer and the guidewire used. The "Direct Wire Pacing technique" is simplified, secured and more reproducible.
During percutaneous cardiovascular interventions such as Transcatheter Heart Valve or coronary intervention, temporary cardiac stimulation may be required. Usually this stimulation is generated via a temporary pacing catheter in the right ventricle. This procedure requires an additional venous access and the insertion of the stimulation catheter, which are both likely to generate complications. In order to reduce the complexity and increase the safety of the procedure, a new stimulation strategy has been developed: the "Direct Wire Pacing technique". In this approach, the specific venous access and the implantation of a stimulation catheter are avoided. The cardiac stimulation is provided via the guidewire inserted into the left ventricle or into the coronary arteries. This guidewire is connected to an external Pacemaker using an alligator clamp (Cathode). The Pacemaker anode is also connected using a clamp attached to a needle piercing the subcutaneous tissue, obtaining a closed electrical circuit. This technique was validated during previous studies in the TAVI context through two registries and one randomized controlled trial. This study demonstrated the superiority of the new technique by showing a reduction of the procedural duration, radiation exposure and costs; with similar efficacy and safety. However the subcutaneous needle insertion is likely to generate electrical pain, risk of bleeding for the patient and risk of blood exposure accident for the operators. This subcutaneous anode increases the stimulation threshold (mA) which can cause stimulation failures. Moreover, several technical difficulties preclude general adoption by the scientific community. This is why the medical device ELECTRODUCER SLEEVE has been developed. This device integrates a pacing function to the introducer and the guidewire used during percutaneous cardiovascular interventions. The guidewire then behaves like an intra-cardiac cathode. Thanks to the device, the complex manipulation of needles and clamps during the intervention are avoided as well as pole inversions. The "Direct Wire Pacing technique" used during the coronary and structural interventions is thus simplified, secured and more reproducible.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Radial group | Experimental | Use of Electroducer Sleeve on radial route |
|
| femoral group | Experimental | Use of Electroducer Sleeve on femoral route |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electroducer Sleeve | Device | The device's safety will be assessed at the radial and femoral puncture site |
|
| Measure | Description | Time Frame |
|---|---|---|
| To assess the peri procedural safety of ELECTRODUCER SLEEVE device used for temporary cardiac pacing during percutaneous cardiovascular interventions, by radial and femoral routes of access. | The device safety is assessed through the occurrence of bleeding complications at the access site where the ELECTRODUCER SLEEVE was used, including: Hematoma formation (EASY Classification) and Access-site Bleeding (BARC classification). | during intervention |
| Measure | Description | Time Frame |
|---|---|---|
| To evaluate the occurrence of Radial Artery Occlusion | RAO evaluated by a radial artery Doppler and by a reverse Allen test | at discharge and 1 month |
| To evaluate the occurrence of allergic or adverse tissue reactions |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| GHMG | Grenoble | France |
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Nov 3, 2021 | |
| Reset | Dec 17, 2021 | |
| Release | Dec 23, 2021 |
Not provided
Pilot, prospective, multicenter, non-comparative study in 60 patients with a percutaneous cardiovascular intervention indication which requires temporary cardiac stimulation.
Not provided
Not provided
Not provided
Not provided
Outcome evaluated through the clinical examination of the puncture site.
| at discharge and 1 month |
| To establish the efficacy of the ELECTRODUCER SLEEVE device | Outcome evaluated through the capture in the surface electrocardiogram : each spike delivered on the guidewire is follow by its hemodynamic effect. | during intervention |
| To evaluate the performance of the ELECTRODUCER SLEEVE device | Performance evaluated through the stimulation threshold (mA) measured with the external pacemaker | during intervention |
| To evaluate the impact of the ELECTRODUCER SLEEVE use on the TAVI procedure duration. | Procedure duration is defined between the first vascular puncture and the last introducer removal and compared to the EASY TAVI study data | during intervention |
| To evaluate the patient comfort with ELECTRODUCER SLEEVE use | Confort evaluated using the "Echelle Visuelle Analogique de la douleur" from 0 to 10: 0 being the absence of pain and 10 being unbearable pain. | during intervention |
| To assess the user's overall impression of the ELECTRODUCER SLEEVE device and use. | Outcome evaluated by a satisfaction questionnaire developed by Electroducer, composed of four questions and a free comment section. | during intervention |
| Reset | Mar 10, 2022 |
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Nov 3, 2021 | Dec 17, 2021 | |||
| Dec 23, 2021 | Mar 10, 2022 |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D006349 | Heart Valve Diseases |
| ID | Term |
|---|---|
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D014652 | Vascular Diseases |
Not provided
Not provided