Comparison of Dynamic Fluid Responsiveness Assessed by Electrical Impedance Tomography and Transpulmonary Thermodilution in Postoperative of Coronary Artery Bypass Grafting Patients
Comparison of Dynamic Fluid Responsiveness Assessed by Electrical Impedance Tomography and Transpulmonary Thermodilution in Postoperative of Coronary Artery Bypass Grafting Patients
The purpose of this study is to evaluate the stroke volume variation measured by both methods: transpulmonary thermodilution and electrical impedance tomography (EIT), during fluid responsiveness maneuvers and after fluid replacement in the immediate postoperative of coronary artery bypass grafting (CABG) patients. Patients will be hemodinamically monitored with the VolumeView set in combination with EV1000 clinical platform and the display of valuable volumetric parameters (Edwards Lifesciences, California, USA). Simultaneoulsy, patients will be monitored with Enlight Electrical Impedance Tomography (Timpel, São Paulo, Brazil). Hemodynamic data will be assessed at baseline 1, one minute after the passive leg raising maneuver, after PEEP increment, and after 500 mL of Lactated Ringer's (bolus infusion). Blood gases sample will be assessed before and immediatly after the protocol.
In the ICU, immediately after CABG surgery, patients are submitted to mechanical ventilation (volume-controlled mode with tidal volume = 8mL/Kg of PBW, PEEP = 8cmH2O and FiO2 = 60%, respiratory rate to maintain PaCO2 = 35 - 45 mmHg); hemodynamically monitored with VolumeView set in combination with EV1000 clinical platform and the display of volumetric parameters (Edwards Lifesciences, California, USA). Electrical impedance tomography monitoring (Enlight, Timpel, São Paulo, Brazil) is performed with a pair of electrodes belt attached around the thorax at 4Th - 6Th intercostal space, and a flow sensor attached between the orotracheal tube and the Y connector from the ventilator.
Before initiate the protocol, patients are submitted to a bolus of usual care doses of sedation and muscular blockage (Fentanyl, Midazolam and Cisatracurium).
To assess fluid responsiveness patients will be submitted to two different maneuvers applied in a random way: Passive Leg Raising (PLR) ant PEEP increment (PEEP). And after these maneuvers patients will receive a bolus of 500 ml of Lactated Ringer's.
Measurements are performed one minute after each of these conditions:
Transpulmonary Thermodilution assessment are performed by the injection of 3 cold salines in bolus - the injection volume varied from 10 - 20mL according to the patient's actual weight and EIT assessment are performed by 1 injection of 10 mL of hypertonic saline at 7.5 - 10% according to the patient's actual weight.
Inclusion Criteria:
Exclusion Criteria:
ludhmila@usp.br11-26615000 ext. 5232
rafael.ianotti@gmail.com11-995989126
São Paulo, São Paulo 05403000, Brazil
ludhmila@usp.br11-26615232
rafael.ianotti@gmail.com11-995989126