Anti-vascular endothelial growth factor (VEGF) therapy is currently the mainstay of treatment for diabetic macular edema (DME). One of the main obstacles of anti-VEGF therapy is the need of repeated injections, which carries both economic and compliance problems to the patients.there is a growing evidence that recognises the effectiveness of the use of micropulse laser (MPL) in treatment of DME. with MPL, it is possible to deliver a subthreshold laser that is above the threshold of biochemical effect but below the threshold of a visible, destructive lesion thereby preventing collateral damage.The MPL technique is available at near - infrared 810 nm diode laser (diode MPL) and at 577 nm (yellow MPL). The current study was conducted in order to compare the efficacy of both MPL techniques in the treatment of center involving DME.
This was a prospective randomized comparative study that included 30 eyes of 15 patients with bilateral DME. The patients were recruited from the Retina Clinic at Kasr Al Ainy Hospital, Cairo University. The study's protocol was reviewed and approved by board of the ophthalmology department, Cairo University, and was in concordance with the tents of Declaration of Helsinki. Eligible patients were informed about the study's objectives, methodology, risks and benefits. A written informed consent was obtained from every patient included in this study.Preliminary examination was in the form of slit-lamp examination, fundus examination, intra ocular pressure measurement, and best corrected visual acuity (BCVA) measurement. A spectral domain optical coherence tomogram (OCT) scan was performed to all patients before treatment to measure the central retinal thickness (CRT). The eyes were randomized into two groups; one eye (right eye) of each patient was treated with 577-nm yellow MPL and the other eye (left eye) of the same patient with Infrared 810-nm diode MPL. Changes in the BCVA and CRT were measured after treatment at 1 and 3 months of follow up.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Yellow MPL | Active Comparator |
| |
| Diode MPL | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Yellow micro-pulse laser | Device | applying 577-nm yellow laser in a micro-pulse mode over the macular area including the fovea |
|
| Measure | Description | Time Frame |
|---|---|---|
| Change in Central Retinal Thickness (CRT) | detecting changes in the thickness of the center of the macula | baseline, at 1 month and 3 months after the intervention |
| Change in the Best Corrected Visual Acuity (BCVA) | detecting changes in the the best corrected visual acuity in logMAR. A LogMAR chart comprises rows of letters and is used by ophthalmologists, optometrists and vision scientists to estimate visual acuity. This chart was developed at the National Vision Research Institute of Australia in 1976, and is designed to enable a more accurate estimate of acuity than do other charts (e.g., the Snellen chart). For this reason, the LogMAR chart is recommended, particularly in a research setting. A Snellen score of 6/6 (20/20), indicating that an observer can resolve details as small as 1 minute of visual angle, corresponds to a LogMAR of 0 (since the base-10 logarithm of 1 is 0); a Snellen score of 6/12 (20/40), indicating an observer can resolve details as small as 2 minutes of visual angle, corresponds to a LogMAR of 0.3 (since the base-10 logarithm of 2 is near-approximately 0.3), and so on.Therefore, a higher logMAR scores mean a worse outcome. | baseline, at 1 month and 3 months after the intervention |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Hany S Hamza, MD | Cairo University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of Medicine, Cairo University | Cairo | 11562 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25719988 | Background | Vujosevic S, Martini F, Longhin E, Convento E, Cavarzeran F, Midena E. SUBTHRESHOLD MICROPULSE YELLOW LASER VERSUS SUBTHRESHOLD MICROPULSE INFRARED LASER IN CENTER-INVOLVING DIABETIC MACULAR EDEMA: Morphologic and Functional Safety. Retina. 2015 Aug;35(8):1594-603. doi: 10.1097/IAE.0000000000000521. | |
| 28540655 | Background |
Not provided
Not provided
Not provided
starting 6 months after publication
Individual participant data (IPD) can be shared with researchers who are planning to conduct a similar study. Requests can be sent to the central contacts by email
Not provided
Not provided
one eye (Right) from each patient was assigned to one arm (yellow MPL) and the other eye (Left) of the same patient to the 2nd arm (diode MPL). Therefore, the total number of enrolled participants was 15 contributing to total of 30 eyes (units) i.e there were 15 participants contributing to 15 eyes in each arm of the study.
| ID | Title | Description |
|---|---|---|
| FG000 | Yellow MPL | Yellow micro-pulse laser: applying 577-nm yellow laser in a micro-pulse mode over the macular area including the fovea. One eye (right) of each participant was assigned to this group. |
| FG001 | Diode MPL | Diode micro-pulse laser: applying 810-nm infra-red diode laser in a micro-pulse mode over the macular area including the fovea. One eye (left) of each participant was assigned to this group. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
there were 15 enrolled participants, then two were excluded due to lack of efficacy. So, the analysis population was 13 participants contributing 26 units (eyes).
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Yellow MPL | Yellow micro-pulse laser: applying 577-nm yellow laser in a micro-pulse mode over the macular area including the fovea |
| BG001 | Diode MPL | Diode micro-pulse laser: applying 810-nm infra-red diode laser in a micro-pulse mode over the macular area including the fovea |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | two participants were excluded due to lack of efficacy. |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Change in Central Retinal Thickness (CRT) | detecting changes in the thickness of the center of the macula | Posted | Mean | Standard Deviation | micrometer | baseline, at 1 month and 3 months after the intervention | eyes | eyes |
|
data were collected over 6 months
the interventions used in the trial are localized to the eye with no systemic complications. in addition, no ocular serious events were reported
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Yellow MPL | Yellow micro-pulse laser: applying 577-nm yellow laser in a micro-pulse mode over the macular area including the fovea |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Ahmed Abdelbaki | faculty of medicine, Cairo University | 00201066642728 | a.abdelbaki@kasralainy.edu.eg |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot | Yes | No | No | Study Protocol | Dec 10, 2017 | Apr 21, 2020 | Prot_000.pdf |
| SAP | No | Yes | No | Statistical Analysis Plan | Dec 10, 2017 | Apr 21, 2020 | SAP_001.pdf |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003930 | Diabetic Retinopathy |
| ID | Term |
|---|---|
| D012164 | Retinal Diseases |
| D005128 | Eye Diseases |
| D003925 | Diabetic Angiopathies |
| D014652 | Vascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Diode micro-pulse laser | Device | applying 810-nm infra-red diode laser in a micro-pulse mode over the macular area including the fovea |
|
| Scholz P, Altay L, Fauser S. A Review of Subthreshold Micropulse Laser for Treatment of Macular Disorders. Adv Ther. 2017 Jul;34(7):1528-1555. doi: 10.1007/s12325-017-0559-y. Epub 2017 May 24. |
| BG002 | Total | Total of all reporting groups |
| Mean |
| Standard Deviation |
| years |
|
| Sex: Female, Male | two participants were excluded due to lack of efficacy. | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| Region of Enrollment | two participants were excluded due to lack of efficacy | Number | participants |
|
| Units | Counts |
|---|
| Participants |
|
| eyes |
|
|
| Primary | Change in the Best Corrected Visual Acuity (BCVA) | detecting changes in the the best corrected visual acuity in logMAR. A LogMAR chart comprises rows of letters and is used by ophthalmologists, optometrists and vision scientists to estimate visual acuity. This chart was developed at the National Vision Research Institute of Australia in 1976, and is designed to enable a more accurate estimate of acuity than do other charts (e.g., the Snellen chart). For this reason, the LogMAR chart is recommended, particularly in a research setting. A Snellen score of 6/6 (20/20), indicating that an observer can resolve details as small as 1 minute of visual angle, corresponds to a LogMAR of 0 (since the base-10 logarithm of 1 is 0); a Snellen score of 6/12 (20/40), indicating an observer can resolve details as small as 2 minutes of visual angle, corresponds to a LogMAR of 0.3 (since the base-10 logarithm of 2 is near-approximately 0.3), and so on.Therefore, a higher logMAR scores mean a worse outcome. | Posted | Mean | Standard Deviation | logMar | baseline, at 1 month and 3 months after the intervention | eyes | eyes |
|
|
|
| 0 |
| 15 |
| 0 |
| 15 |
| 0 |
| 15 |
| EG001 | Diode MPL | Diode micro-pulse laser: applying 810-nm infra-red diode laser in a micro-pulse mode over the macular area including the fovea | 0 | 15 | 0 | 15 | 0 | 15 |
Not provided
Not provided
Not provided
| D002318 |
| Cardiovascular Diseases |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |