Patients with COPD are often unable to sustain a sufficient workload during exercise. The use of external strategies to improve exercise tolerance, such as non-invasive ventilation (NIV) and high-flow nasal therapy (HFNT) have been used. The objective was to evaluate and compare the acute effects of HFNT and NIV during exercise on cardiorespiratory parameters, dyspnea, exercise tolerance and comfort in patients with moderate to severe COPD.
The patients underwent an initial clinical examination, with anthropometric evaluation, blood gas analysis, pulmonary function tests and measurement of maximum respiratory pressures. The exercise protocol started in the sector of Ergometry and Cardiopulmonary Exercise Testing. After completing the maximum incremental cardiopulmonary exercise test, two additional visits were scheduled for the three constant load tests. All patients studied underwent an evaluation of cardiopulmonary exercise testing (CPET). During maximum-incremental CPET, breath by breath: oxygen consumption (V̇O2, mL/min), carbon dioxide production (V̇CO2, mL/min), respiratory exchange rate (RER), minute ventilation VE (L/min), respiratory rate (bpm), equivalent ventilation for O2 and CO2 (V̇E/V̇O2 and V̇E/V̇CO2). In addition, cardiac monitoring was performed by 12-lead electrocardiogram (ECG) throughout the procedure. On the day of the experiment, the patients underwent two cardiopulmonary exercises with constant-load at 90% of the previously determined peak, separated by an interval of at least 1 hour.
The NIV parameters were adjusted for each patient with Trilogy 100 (Philipsâ„¢). Spontaneous ventilation mode was set before the protocol for all patients, and a previous period of NIV adaptation was performed to titrate the inspiratory and expiratory pressures. The adaptation period started with the minimum Inspiratory Positive Airway Pressure (IPAP) value of 15cmH2O, and, every 2 minutes, increasing the pressure every 2 cmH2O according to the patient's tolerance.16 The Expiratory Positive Airway Pressure (EPAP) was programmed to vary between 4 and 6 cmH2O. Before the start of the examination, an adaptation was performed with the selected mask and initial ventilator settings for 20 min. No additional oxygen was offered.
The high flow system used was Optiflow® (Fisher & Paykel Healthcare, Auckland, New Zealand). Before the test, flow titration was performed for the patient, which started with the administration of a minimum gas flow of 30L/min and, every 2 minutes, the flow was increased by 5L/min according to patient tolerance. The test only started after 20 minutes of adaptation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Control | Active Comparator | The cardiopulmonary exercise test was performed with patient breathing room air. |
|
| NIV | Active Comparator | The cardiopulmonary exercise test was performed with non-invasive ventilation during the test. |
|
| HFNT | Active Comparator | The cardiopulmonary exercise test was performed with a High flow nasal therapy during the test. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High flow nasal therapy | Other | All patients underwent two cardiopulmonary exercises with constant-load at 90% of the peak workload. The high flow nasal therapy was used during all exercise test. |
| Measure | Description | Time Frame |
|---|---|---|
| Exercise dinamic hyperinflation | To determine the dinamic hyperinflation during exercise test with 3-different situations , Control, NIV and HFNT. During all testes the dinamic hyperinflation will be measured by inspiratory capacity (at rest and at the end o exercise test) and will be demonstrated as porcentage os maximum. | one week after all tests |
| Exercise Tolerance | To determine the exercise tolerance with 3-different situations , Control, NIV and HFNT. Time of exercise test will be measured to determine which test could be the best for COPD patients. In additional, the workload will (treadmill inclination and speed) be check to show which intervention has the better response. | one week after all tests |
| Measure | Description | Time Frame |
|---|---|---|
| Dyspnea | To determine the dyspnea during exercise test with 3-different situations , Control, NIV and HFNT. After all situations, Borg scale will be performed to check the dyspnea score at the end of exercise. | one week after all tests |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Federal University of Ceara | Fortaleza | Ceará | 60.430-370 | Brazil |
This is study will be submitted to a medical journal.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D029424 | Pulmonary Disease, Chronic Obstructive |
| D009043 | Motor Activity |
| ID | Term |
|---|---|
| D008173 | Lung Diseases, Obstructive |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
| D002908 | Chronic Disease |
Not provided
Not provided
| ID | Term |
|---|---|
| D063087 | Noninvasive Ventilation |
| ID | Term |
|---|---|
| D012121 | Respiration, Artificial |
| D058109 | Airway Management |
| D013812 | Therapeutics |
| D012138 | Respiratory Therapy |
Not provided
Not provided
One single COPD group performed 3 differents tests, Control exercise, VNI exercise and HFNT exercise on different days.
Not provided
Not provided
Not provided
Not provided
| Non-invasive ventilation | Other | All patients underwent two cardiopulmonary exercises with constant-load at 90% of the peak workload. The NIV was used during all exercise test. |
|
| Control | Other | All patients underwent two cardiopulmonary exercises with constant-load at 90% of the peak workload. The control test was performed with no additional therapy. |
|
| D020969 |
| Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001519 | Behavior |