The purpose of this trial is to assess the efficacy of the Xoft Axxent eBx System when used for single-fraction IORT in early stage breast cancer. A comparison will be made to the current standard of care, whole breast irradiation (WBI), in women with early stage breast cancer.
The rationale for IORT as the sole radiation therapy is:
Favorable preliminary results in feasibility, safety and efficacy outcomes: Accelerated Partial Breast Irradiation (APBI) is an accepted alternative to whole breast irradiation following breast-conserving surgery for early stage breast cancer. Intra-Operative Radiation Therapy (IORT) is a form of APBI that allows radiation to be delivered directly to the open tumor bed following Breast Conservation Surgery (BCS). After 4 years of follow-up, IORT has shown equivalent disease control rates as whole breast irradiation.
Direct and timely radiation to the tumor bed: Radiation is delivered at to the target tissue (adjacent to the resection margins at the time of lumpectomy). It avoids treatment delays and eliminates weeks or months of post-surgical radiation therapy during which residual cancer cells might proliferate. An in vitro study showed that un-irradiated wound fluid stimulated the growth of breast cancer cells while irradiated wound fluid did not. Each month of delay in radiation treatment is associated with a 1% increase in the recurrence rate. Huang, et al., found a 5.8% recurrence rate in patients who received WBRT within 8 weeks of BCS compared with a 9.1% recurrence rate in patients who started radiotherapy 9-16 weeks after BCS.
Increased patient treatment compliance compared to conventional radiation therapy: Suitable early stage breast cancer patients are able to complete their breast cancer radiotherapy treatment at the time of BCS, which offers a convenient and potentially life-saving benefit to patients who might otherwise omit radiation therapy if it required lengthy travel or time commitments. In addition, healthcare resources, including both personnel and facilities, will be conserved by eliminating the overhead cost of multiple patient visits, eliminating waiting time for patients, and consolidating therapy to one visit combined with the surgical procedure.
Available Technology: The Xoft Axxent controller, x-ray source, and balloon applicator are cleared by the United States Food and Drug Administration (FDA) to deliver brachytherapy treatments using high dose rate x-ray radiation. The Xoft Axxent System has been used to treat breast cancer subjects using a multi-fraction APBI technique on an outpatient basis as part of two multi-center studies. The Xoft Axxent System enables the Radiation Oncologist to administer electronic brachytherapy without the use of a radioactive isotope in minimally shielded rooms. Characteristics of the Xoft System that make it well-suited for IORT include its portability and low energy photons, allowing for minimal shielding during the radiation therapy.
This protocol has been developed to further study the use of the Xoft Axxent eBx System in the delivery of IORT for subjects with early-stage breast cancer. The Xoft Axxent eBx System will be used according to the United States Food and Drug Administration (FDA) 510(k) cleared labeling; therefore, the use of the technology in this study is considered on-label and within the scope of the FDA cleared indication.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Experimental: Intra-operative Radiation Therapy - IORT | Other | Intra-operative Radiation Therapy |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Intra-operative Radiation Therapy - IORT | Radiation | Single dose of 20 Gy |
|
| Measure | Description | Time Frame |
|---|---|---|
| Assess the rate of ipsilateral breast tumor recurrence (IBTR) at 5 years | To assess the rate of ipsilateral breast tumor recurrence in subjects treated with the Xoft Axxent Electronic Brachytherapy System when used for single-fraction, intra-operative radiation therapy treatment of early stage breast cancer when compared to whole breast irradiation (WBI) at 5 years of follow-up | Reported at 5 years |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| A. M. Nisar Syed, MD | Long Beach Memorial Medical Center | Principal Investigator |
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 20737219 | Background | Ivanov O, Dickler A, Lum BY, Pellicane JV, Francescatti DS. Twelve-month follow-up results of a trial utilizing Axxent electronic brachytherapy to deliver intraoperative radiation therapy for early-stage breast cancer. Ann Surg Oncol. 2011 Feb;18(2):453-8. doi: 10.1245/s10434-010-1283-x. Epub 2010 Aug 25. | |
| 19254369 | Background |
| Label | URL |
|---|---|
| National Cancer Institute Factsheet - Radiation Therapy for Cancer | View source |
Not provided
No IPD will be shared.
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002285 | Carcinoma, Intraductal, Noninfiltrating |
| ID | Term |
|---|---|
| D000230 | Adenocarcinoma |
| D002277 | Carcinoma |
| D009375 | Neoplasms, Glandular and Epithelial |
| D009370 | Neoplasms by Histologic Type |
Not provided
Not provided
Single 20Gy dose of electronic brachytherapy (IORT)
Not provided
Not provided
Not provided
Not provided
| Dickler A, Ivanov O, Francescatti D. Intraoperative radiation therapy in the treatment of early-stage breast cancer utilizing xoft axxent electronic brachytherapy. World J Surg Oncol. 2009 Mar 2;7:24. doi: 10.1186/1477-7819-7-24. |
| D009369 | Neoplasms |
| D000071960 | Breast Carcinoma In Situ |
| D002278 | Carcinoma in Situ |
| D018299 | Neoplasms, Ductal, Lobular, and Medullary |