Clinical Performance of the VivaDiag ™ COVID-19 lgM / IgG Rapid Test in a Cohort of Negative Patients for Coronavirus Infection for the Early Detection of Positive Antibodies for COVID-19
Clinical Performance of the VivaDiag ™ COVID-19 lgM / IgG Rapid Test in a Cohort of Negative Patients for Coronavirus Infection for the Early Detection of Positive Antibodies for COVID-19
This study aim to evaluate the immune response of negative patients during a COVID-19 outbreak.
Patients are serially tested with a VivaDiag ™ COVID-19 lgM / IgG Rapid Test to evaluate the immune response in negative patients and the reliability of the test in those patients who develop clinical signs of COVID-19 during the trial.
This study aim to evaluate the immune response of negative patients during a COVID-19 outbreak in patients with no symptoms and with no known exposure to the COVID-19.
Patients are tested with a VivaDiag ™ COVID-19 lgM / IgG Rapid Test at day 0, day 7 and day 14. The investigators expect test to be negative on all the measurements in those patients that do not develop symptoms and that continue to have no known history of exposure to COVID-19
Patients that develop symptoms (cough, fever or respiratory distress) and a possible contact with people positive for COVID-19 OR patients that show a positive VivaDiag test during the time frame of the test are asked to attend the COVID-19 RT - PCR &CT.
Subsequently, the investigators will continue, repeating two tests seven days apart every 30 days (predefined times 0-7-14, then 30-37, 60-67) for the next six months. The investigators can evaluate to stop the test however before the six months if there are no new cases of COVID-19 for at least 21 days in the region where the enrolled patients live.
The test in use is the VivaDiag ™ COVID-19 lgM / IgG
Procedure (as per the protocol in use for the administration of the test)
Interpretation of test results
Positive result
Negative result The anti-COVID-19 lgG and lgM antibodies are not detected if only the quality control C band is stained but the lgG and lgM bands are not colored, this means that the test is negative.
Invalid result
If the quality control band C does not color, regardless of whether the lgG and lgM bands are colored or not, the result is invalid and the test must be started again.
Specs of the test
Product Name VivaDiag™ COVID-19 IgM/IgG Rapid Test Test Principle Colloidal gold Sample Type Whole blood (from vein or fingertip), serum or plasma Sample Volume 10 μL Test Time 15 min Operation Temperature 18-25ºC Storage Temperature 2-30ºC Shelf Life (Unopened) 12 months
Inclusion Criteria:
Exclusion Criteria:
antonio.gaddi@ehealth.study+393920039246