Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study aimed to evaluate the influence of a 635nm diode laser on the stability of orthodontic mini-implants in vitro, as well as mini-implants failure rate (mini-implant loss) and patients pain level after the treatment. A randomized clinical split-mouth trial was concluded with 22 subjects (14 women, 8 men), 44 orthodontic mini-implants with a diameter 1.4mm and length of 10mm. Mini-implants were placed between teeth 3 and 4; and 13 and 14 (Universal Numbering System), in the area of the attached gingiva, 2 mm below mucogingival junction.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Right side of the maxilla | Experimental |
| |
| Left side of the maxilla | No Intervention |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Irradiation of implants with 808nm laser | Procedure | Irradiation of implants with 808nm laser |
|
| Measure | Description | Time Frame |
|---|---|---|
| stability of orthodontic mini-implants | The mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects. | 60 days |
| Measure | Description | Time Frame |
|---|---|---|
| Pain level (NRS scale) | Each patient received a questionnaire for individual pain assessment (the numeric rating scale, NRS-11, grade level 0-10) immediately following placement of mini-implants. The maximum pain level was measured at both sides of the maxilla during the first day after the treatment. The NRS-11 scale consists of a conscious, subjective assessment of the pain experienced; therefore, it is used in the case of patients over ten years old. 0 = no pain, 1-3 = mild pain, 4-6 = moderate pain, 7-10 = severe pain. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Private Dental Healtcare | Kościan | Poland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008312 | Malocclusion, Angle Class II |
| ID | Term |
|---|---|
| D008310 | Malocclusion |
| D014076 | Tooth Diseases |
| D009057 | Stomatognathic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D007834 | Lasers |
| ID | Term |
|---|---|
| D055096 | Optical Devices |
| D004864 | Equipment and Supplies |
| D055618 | Radiation Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 24 hours |
| mini-implants loss | Mini-implants survival rate was assessed during 60 days observation period. | 60 days |