this study evaluates the post-surgical correction of enophthalmos and orbital volume using 3D printed only versus pre-bent titanium mesh in blow-out fracture cases
Many materials had been used in reconstruction of blow out fractures, the aim of this study is to evaluate the enophthalmos correction and orbital volume restoration using 3D printed onlay versus pre-bent titanium mesh
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Orbital fractues | Other | Orbital fractures |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 3D printed PEEK onlay | Combination Product | 3d computer-designed Orbital onlay |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Enophthalmos | CT based exphthalmometery - corneal projection from lateral orbital rim measured in millimeters | 1 week post-operative |
| Enophthalmos | CT based - corneal projection from lateral orbital rim measured in millimeters | 1 year post-operative |
| Measure | Description | Time Frame |
|---|---|---|
| Orbital volume | Change in orbital volume ratio on CT in centimeter cubic | one week post-operative |
| Implant position accuracy | Superimposition of pre- and post-operative 3d bony structures on CT in 2d views of the x-ray |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Khalid Amr, PhD | Contact | +201006029031 | khaledamr82@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Ahmed Mohamed, PhD | Cairo University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Faculty of Dentistry - Cairo University | Cairo | 11553 | Egypt |
Not provided
| ID | Term |
|---|---|
| D009917 | Orbital Fractures |
| D015841 | Enophthalmos |
| ID | Term |
|---|---|
| D008446 | Maxillofacial Injuries |
| D005151 | Facial Injuries |
| D006259 | Craniocerebral Trauma |
| D020196 | Trauma, Nervous System |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Pre-bent orbital mesh |
| Combination Product |
Pre-bent orbital mesh on 3d printed template |
|
| One week post-operative |
| D009422 |
| Nervous System Diseases |
| D012887 | Skull Fractures |
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
| D009916 | Orbital Diseases |
| D005128 | Eye Diseases |